Tender For corrigendum : operation and maintenance of complete water supply network system inclg mechanical, electrical, instrumentation installation works, switchyard gss and maintenance of pipe line of jaisamand scheme, uwss udaipur on performance cum operation and maintenance basis for 06 months, on private
Tender For invitation for pre-tender meet for composite works (mechanical, electrical,instrumentation) for u and o of bprep projects of bpcl,bina refinery for bina petchem and refinery expansion project (bprep)
Tender For corrigendum : operation and maintenance of complete water supply network system including mechanical electricalinstrumentation installation works switchyard gss and maintenance of pipe line of jaisamand water supply scheme uwss udaipur on performance cum o an
Tender For supply of data terminal equipment smart plus , radio interface cable smart to radio , hand set , ni cd battery 12v 2. 2ah smart plus , bty box , external battery adopter box ebab , mains adopter unit 24v dc , mains power cable 3m , inter connecting cable ebab to mau , battery cable for ext 12v secondary battery , dot matrix serial printer , printer cable smart to printer , battery charging adopter , battery charging cable , carrying case , pc interface s w smart plus , cable accessories 01 mtr , pc adaptor 9 pd female to 25 p dfe , usb rs 232 serial port dual , inverter 12v dc to 230v ac
Tender For corrigendum : operation and maintenance of mansi wakal dam stage i complete system including mechanical, electrical, instrumentation installation works
Tender For design, construction, supply, installation, testing and commissioning (civil, electro-mechanical, electrical, instrumentation & other necessary works) of sewage treatment plant (sbr technology) capacity of 1 mld, sewage collection tank for dsc area along with pump rooms, inlet & outlet connection lines & other miscellaneous works for ordinance factory and operation and maintenance of 1mld stp for 36 months at oft campus, trichy
Tender For providing of calibration services - mechanical, electrical, instrumentation; voltage, current, power (ac/dc), frequency, power factor, phase angle, resistance, gas analysis, pressure and vacuum, pressure safety valve, rpm; nabl accredited / any other approved te..
Tender For design, engineering, procurement, fabrication, supply, erection and commissioning (epc) of electrical, instrumentation and control scope of ccu plant at thermax ltd, pune.
Tender For provn of dry ration stores under ge 881 ews - sch a part-i (building work):-this schedule is not pre-priced by mes and the pre-priced rate indicated as "rs. 0.00" under col.5 signifies this fact only., construction of block of storage shed complete all as shown on drawings and as specified., total amount of sch a part - ii (site clearance/development work), total amount of sch a part - iii (internal electric supply work), total amount of sch a part - iv (protective work), total amount of sch a part - v (area drainage work), total amount of sch a part -vi (road, path and culvert work), total amount of sch a part -vii (external electric supply work), total amount of sch a part -viii (demolition/dismantling work), sch a part - ix (misc items of work) note : this schedule is not pre-priced by mes and the pre-priced rate indicated as "rs. 0.00" under col.5 signifies this fact only., double walled corrugated (dwc) pipe for cable protection with outer dia 50mm and inner dia 38mm including suitable size of coupler for connection of pipe complete all as specified and directed., point wiring for one light/fan point/call bell point controlled by one way switch 5 amp with 1.5 sqmm single core multi standed copper conductor frlsh insulated and unsheathed heavy duty cable in colour code including earth wire with cable of size 1.5 sqmm copper conductor frlsh insulated, drawn into and including concealed in pvc conduit of not less than 20mm dia and 1.5mm wall thickness (isi marked) terminated into annealed steel terminal boxes including modular plate and cover for mounting modular switch/ socket switches, sockets, fan regulators etc complete all as specified and directed., all as per srl item no. 12.00 above but for one 3 pin 5 amp socket on same board., all as per srl item no. 12.00 above but for one 3 pin 5 amp socket on independent board., earthing complete with galvanized steel earth plate electrode 600x600x6mm burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of earth plate not less than 1.5m below normal ground level connected with galvanized iron earth lead wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel complete with 15mm dia gi light grade protection pipe, 20mm dia gi medium grade watering pipe with funnel including charcoal, dust, salt, pcc m-15 type b1 in pit with angle iron (25x25x3)mm frame work with precast rcc 1:2:4 type b-1 cover reinforced with 8mm dia tmt bars @ 150mm c/c both ways and 12mm dia ms fabricated handle, test point etc. in and including light grade gi protection pipe 20mm bore up to 7.5m length for drawing in earth lead wire, all as shown in electric plate no. 3 of ssr part-i complete with necessary earth work in any type of soil, removal of soil to a distance not exc. 50m, testing on completion complete all as specified and directed.note:- on testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost to the entire satisfaction., inverter led light fittings batten type, 1x20w led, 230v, complete with all accessories internally per wired including lithium lon battery with charging time 8 to 10 hours and back up time up to 4 hours and connecting up with pvc insulated and sheathed, 1100 v grade, flexible, multistranded copper conductor three core cable complete all as specified and directed., led street light/ security light fitting 35 watt, 230 v, ac, outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with ip 66 protection, including provision of gi bracket made of 40mm dia, gi pipe, 1.5m long, bend to shape, complete all as specified., mcb, spn, 240 volts, 40 to 63 amps,10ka, breaking capacity, complete all as specified., mcb, spn, 240 volts, 6 to 32 amps,10ka, breaking capacity,