Tender For corrigendum : tender for supply of closing coil-220v dc , tripping coil - 220v dc , vacuum interrupter stelmec make , breaker control switch(non-lockable) , spring charging motor , 220v ac , breaker auxiliary switch(8no+8nc) , breaker limit switch stelmec make , epoxy housing stelmec , drive insulator stelmec , tulip contact assembly (1250 a) stelmec , spout(1250 a) for r , y and b phases , closing spring assembly with 40ka mechn. , power relay/solid state relay 220 v dc , 32 pin plug and socket , p/n e0000001369
Tender For supply of anti pumping relay 11 pin 110v ac, part no. 1901709 , rectifier bridge unit 60 or 63a 600piv 100v, part no. 1925362 , machanism motor wound spring charged 25k, part no. 1435279 , switch auxiliary assembly, part no. 2120276 , spring charging motor, part no. 1435530 , mechanism catch 25ka, part no. 1435292 , shunt trip coil 110 v dc, part no. 2064674 , vtc or closing coil 110 v dc, part no. 2064613 , fuse, ht,pt,11kv,5a , pt resin cast 3ph 5 limb 6.6kv or 110v or 63, part no. 2267718 , epoxy resin cast current transformer rat, part no. ba1132 , current transformer ctr 600 300 or 5, part no. ctr600300 , relay e or l 50a 1a 110v ac, part no. 1902284 , idmt relay, part no. p0083 , bus bar spout 1200 amp, part no. mv3308 , support insulator for fixed type vcb p00, part no. p0063 , 3.3kv or 6.6kv off load isolator assy upt, part no. 100030 , clamp, al,55mm,strght,busbr , switch, lmt,stopper,220v,10a,2no plus 2nc , padlocing, part no. pcvc3338 , switch control breaker pistol grip, part no. 2121074 , mvng contact, isltr,11kv,outdoor,630 or 800a , vcb 11 kv 1250a25kambl, part no. 418535
Tender For corrigendum : for running contract for hon,ble sansad nidhi/vidhayak nidhi and other deposit works under edd-budaun (semi turnkey). - cartage of following material from store center nawada, budaun to je store/je store to site of work including loading & unloading at both ends maximum distance up to 30 km., a) pcc pole 8.5 mrt long/st pole 11 mtr long., b) 11 kv xlpe cable of 3x70/3x120/3x185/3x300 sq.mm., c) 250/400 kva t/f., d) 11 kv ct/pt unit of different size, e) 11 kv jointing kit of different size, f) 11 kv pilfer proof cubical of different size, g) lt abc cable of size 1x16, 3x50, 3x95, 3x120 sq.mm., cartage of line material (11 kv pin insulator, disc insulator, stay set, cross arm, gi wire, earthing rod, ms channel, ms angle, etc) from store centre to dump site & then dump site to site of work on day to day basis, including loading & unloading at both ends maximum distance up to 30 km., cartage of 10 kva & 25 kva transformer from store centre to site of work including loading & unloading at both site, the work of safe carriage 11 kv o/g vcb store center nawada budaun to work of site distance up to 0 to 30 km including safe loading & unloading., cartage of 63 kva to 100 kva transformer from store centre to site of work including loading & unloading at both site., earthing of each 11 kv line pole & t/f properly after drive of electrodes if size 20mmx250mm and connection the earthing point with gi wire., erection of pcc pole 8.5 mtr long after digging a pit of size 1.20 x 0.60 x 1.6 mtr in all type of soil including back filling of the pole with proper ramming after completion of work., erection of stp pole 11 mrt long after digging a pit of size 1.20 x 0.60 x 1.6 mtr in all type of soil including back filling of the pole with proper ramming after completion of work., fabrication and fixing of all 11 kv h.t/l.t. line accessories., erection of double pole on pcc pole 8.5 mtr/stp 11 mtr. long after digging of pit of required size including fabrication and fixing of top channel, droper channel & base channel alongwith, fixing all 11 kv accessories, fuse set 11 kv pin insulators and making connection properly., construction of new plinth for 250/400 kva as per uppcl norms, mounting of 250/400 kva t/f on plinth as per uppcl norms, providing and fixing wiremess fencing for 250/400 kva, erection/installation of following of vcb o/g in consumers site and cable joint of the panel to including earthing, grouting, anchor bolt of panel of making/repairing of pocket for cable to insert in panel form trench and fixing taping of busbar with wiring for ac,dc connection including providing ac and dc supply., chemical earthing for 250/400 kva t/f neutral and body complete, chemical earthing for vcb o/g, mounting of 10 & 25 kva t/f with proper jumping of ht side and fixing of cable on lt. side of t/f making connection properly., mounting of 63 & 100 kva t/f with proper jumping of ht side and fixing of cable on lt. side of t/f making connection properly., mounting of ct/pt unit with proper jumping of ht side and fixing of cable on lt. side of meter cubical properly, fixing of meter cubical as per uppcl norms, making a section pole to exist pole after fabrication & fixing of t channel fixing of all 11 kv accessories., erection of stay rod complete after digging a pit of size 1.20 x 0.60 x 1.6 mtr and grouting the same in block of size 0.60 x 0.60 x 0.30 mtr and nuzzling at the both ends and filling the pit with excavated earth soil with proper ramming., laying lifting stringing of proper sagging of acsr weasel/rabbit/dog conductor for 3 phase, 3 wire 11 kv line including binding & jumpering properly., laying lifting stringing of proper sagging of 11 kv xlpe cable of 3x70, 3x120, 3x185, 3x300 sq.mm., laying of underground 11 kv xlpe cable of 3x70, 3x120, 3x185, 3x300 sq.mm. sizes with open trench by brick & sand as per uppcl norms., filling the 11 kv jointing kit (joint kit providing by c
Tender For corrigendum : procurement of spares of mineline private limited make flp vcb 3 3kv flp tsu 3 3kv 550v flp acb etc - isolator 400a , vacuum circuit breaker 3.3kv , potential transformer 3.3 kv , hrc ht pt fuse , primary side p.t fuse plate wiring assembly , h.t. control plate wiring assembly , voltmeter , fuse terminal , multicore bushing , indicating lamp , 3.3kv adopter , 3.3kv coupler , bullet pin 3.3kv , hv bushing , dc power pack , neutral monitoring relay with resistance , earth leakage 50 750m a and 750ma 2a dual settings , earth leakage relay 50 750m a with time lag with cbct , overload short circuit and motor protection relay , vcb aux .rotary switch , control relay , ht bushing , vcb shunt trip coil , timer , 3 pole oil dashpot relay , cover bolts , insulator assembly k3 on off , overload assembly breaker 110a 200a , overload assembly breaker 310a 400a , overload coil 200a , short trip assembly complete , shunt trip coils , no volt coil assy. under voltage coil assy. with moulding , catcher assembly , arc chutes , ammeter 200 5 for acb , ammeter 100 5 for acb , ammeter 300 5 for acb , ammeter 400 5 for acb , busbar , potential transformer , brass cone and gland assembly , indicating lamps , power cable for 300a for breaker chamber ic and og , limit switch 2no 2nc for breaker , brass terminal for cp , brass terminal with dmc insulator , terminal bushing insulator dmc incoming 10mmx25mm , on off isolator 300a , split type terminal box , on off isolator 400a , circuit breaker for 100a with complete assy. , circuit breaker for 200a with complete assy. , complete control wiring including pla relay ptds elm7 control fuses control plate wiring harness etc mounted on control plate or circuit breaker for 300a with complete assy , complete control wiring including pla relay ptds elm7 control fuses control plate wiring harness etc mounted on control plate or circuit breaker for 400a with complete assy , earth leakage 50 750m a with time lag , core balance transformer , on off isolator 100a , isolator handle , 1ph 5kva lighting transformer 550 440v sec.110v with mid point earthed , earth leakage relay , brass terminal with dmc bushing , brass stud with dmc bushing for og , magnetic ol relay , thermal ol relay , on delay timer , push button and element , isolator on off rev 100a , pilot relay , switch module , isolator on off rev 200a , on off rev isolator 300a , copper terminal bushing cp og , aux. contactor 220v ac , resistance