Get complete information related to latest Electrician Equipment Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Electrician Equipment Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Electrician Equipment Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :40580359 Due date: 24 Jun, 202524 Jun, 2025 NA
Tender For supply of 33kv vcb trolley and vcb spares - hvx o gen 3 33kv 800 or 1250 amps 25 ka beaker trolley without pt and surge arrestor , isolating contact vertical finger type 36kv, 26 point three ka 1250a , deflector with vertical finger type isolating contact arrangement 4 fingers 1250 a , cam disc complete , microswitch assy for racking trolley , closing or tripping coils assembly with hardwares 110 v dc rating , spout without fixed contact for 1250 a breaker , busbar or circuit spout contact upto 1250a,breaker and mtx applicable for both aluminium and copper riser , busbar or circuit deflector upto 1250a, breaker and mtx applicable for both aluminium and copper riser , capacitive insulator live line indicator , phase barrier sheet phase separator , breaker floor wheel with hardware , scrape earthing assy with hardware

Central Government/Public Sector

CTN :40241609 Due date: 09 Jun, 202509 Jun, 2025 NA
Tender For corrigendum : supply of lt line spacer and insulator - lt line spacer and insulator 095500029 , lt line spacer and insulator 095500030 , lt line spacer and insulator 095500031 , lt line spacer and insulator 095500032 , lt line spacer and insulator 401900046

CTN :40599747 Due date: 26 Jun, 202526 Jun, 2025 NA
Tender For puncture insulator detection of porcelain insulator string of 132 kv srinagar rishikesh line

CTN :40553802 Due date: 09 Jun, 202509 Jun, 2025 NA
Tender For srm e-tender 2nd call for rate contract of cold line washing of insulator strings of 400kv r.s o &m dn chakan.

CTN :40319578 Due date: 05 Jun, 202505 Jun, 2025 18.23 Lacs
Tender For corrigendum : for running contract for hon,ble sansad nidhi/vidhayak nidhi and other deposit works under edd-budaun (semi turnkey). - cartage of following material from store center nawada, budaun to je store/je store to site of work including loading & unloading at both ends maximum distance up to 30 km., a) pcc pole 8.5 mrt long/st pole 11 mtr long., b) 11 kv xlpe cable of 3x70/3x120/3x185/3x300 sq.mm., c) 250/400 kva t/f., d) 11 kv ct/pt unit of different size, e) 11 kv jointing kit of different size, f) 11 kv pilfer proof cubical of different size, g) lt abc cable of size 1x16, 3x50, 3x95, 3x120 sq.mm., cartage of line material (11 kv pin insulator, disc insulator, stay set, cross arm, gi wire, earthing rod, ms channel, ms angle, etc) from store centre to dump site & then dump site to site of work on day to day basis, including loading & unloading at both ends maximum distance up to 30 km., cartage of 10 kva & 25 kva transformer from store centre to site of work including loading & unloading at both site, the work of safe carriage 11 kv o/g vcb store center nawada budaun to work of site distance up to 0 to 30 km including safe loading & unloading., cartage of 63 kva to 100 kva transformer from store centre to site of work including loading & unloading at both site., earthing of each 11 kv line pole & t/f properly after drive of electrodes if size 20mmx250mm and connection the earthing point with gi wire., erection of pcc pole 8.5 mtr long after digging a pit of size 1.20 x 0.60 x 1.6 mtr in all type of soil including back filling of the pole with proper ramming after completion of work., erection of stp pole 11 mrt long after digging a pit of size 1.20 x 0.60 x 1.6 mtr in all type of soil including back filling of the pole with proper ramming after completion of work., fabrication and fixing of all 11 kv h.t/l.t. line accessories., erection of double pole on pcc pole 8.5 mtr/stp 11 mtr. long after digging of pit of required size including fabrication and fixing of top channel, droper channel & base channel alongwith, fixing all 11 kv accessories, fuse set 11 kv pin insulators and making connection properly., construction of new plinth for 250/400 kva as per uppcl norms, mounting of 250/400 kva t/f on plinth as per uppcl norms, providing and fixing wiremess fencing for 250/400 kva, erection/installation of following of vcb o/g in consumers site and cable joint of the panel to including earthing, grouting, anchor bolt of panel of making/repairing of pocket for cable to insert in panel form trench and fixing taping of busbar with wiring for ac,dc connection including providing ac and dc supply., chemical earthing for 250/400 kva t/f neutral and body complete, chemical earthing for vcb o/g, mounting of 10 & 25 kva t/f with proper jumping of ht side and fixing of cable on lt. side of t/f making connection properly., mounting of 63 & 100 kva t/f with proper jumping of ht side and fixing of cable on lt. side of t/f making connection properly., mounting of ct/pt unit with proper jumping of ht side and fixing of cable on lt. side of meter cubical properly, fixing of meter cubical as per uppcl norms, making a section pole to exist pole after fabrication & fixing of t channel fixing of all 11 kv accessories., erection of stay rod complete after digging a pit of size 1.20 x 0.60 x 1.6 mtr and grouting the same in block of size 0.60 x 0.60 x 0.30 mtr and nuzzling at the both ends and filling the pit with excavated earth soil with proper ramming., laying lifting stringing of proper sagging of acsr weasel/rabbit/dog conductor for 3 phase, 3 wire 11 kv line including binding & jumpering properly., laying lifting stringing of proper sagging of 11 kv xlpe cable of 3x70, 3x120, 3x185, 3x300 sq.mm., laying of underground 11 kv xlpe cable of 3x70, 3x120, 3x185, 3x300 sq.mm. sizes with open trench by brick & sand as per uppcl norms., filling the 11 kv jointing kit (joint kit providing by c

CTN :40535528 Due date: 25 Jun, 202525 Jun, 2025 NA
Tender For work for puncture insulation detection (pid) of porcelain disc insulator string of 132kv sidcul-jwalapur line ckt-i & ii associated with 220kv s/s, sidcul, haridwar.

State Government

CTN :40237563 Due date: 16 Jun, 202516 Jun, 2025 NA
Tender For corrigendum : tender for supply of equipment materail design erection testing and commisioning for providing sop to jsv by providing aug of existing 25 kva sstn singnahar to 63 kva aw providing 1phase ld system to jsv main storage in es pukhri under esd koti - 1-ph lt line on st poles with acsr conductor (0.545 km) -supply part, steel tubular poles 8 mtr. long, muff for steel tubular pole with concrete filling, acsr conductor 6/1/2.59, 30 sq.mm, gi wire 8 swg, lt stay set complete, egg insulator (lt), shackle insulator (16kn) (recd-3/761)(iss no 1445/1977), d-iron (u-clamp), nuts and bolts offsizes, aluminium paint, red oxide paint, full clamp, earth knob, lt earthing set complete, spiral pvc spacer (1-phase, 1-ph lt line on st poles with acsr conductor (0.545 km) -erection part, steel tubular poles 8 mtr. long, muff for steel tubular pole with concrete filling, acsr conductor 6/1/2.59, 30 sq.mm, gi wire 8 swg, lt stay set, egg insulator (lt), stay wire (7/10 swg), shackle insulator (16kn) (recd-3/761)(iss no 1445/1977), d-iron (u-clamp), nuts and bolts offsizes, aluminium paint, red oxide paint, full clamp, earth knob, lt earthing set complete, spiral pvc spacer (1-phase, transportation charges ( mechanical transportation+manual carriage for avg lead 2 km), augmentation of existing 11/0.4 kv 25 kva s/stn singnahar to 63 kva in section pukhri-supply part, 11/0.4 kv, 63 kva distribution transformer ( outdoor type) from approved vendor of hpsebl, acsr conductor 6/1/3.35, 50 sq.mm, pipe earthing set i/c coal, charcoal, salt, surge arrester, 9 kv station class (porcelain type), muffs with concrete filling for existing poles in structire, lt distribution panel box with mccb for 63 kva dtr, aluminium paint, lt pvc cable 3.5 core 120 sq. mm, prov. hp make aiq desktop model hp 200 g4 with intell core 3-10110u-10 gen, processor, 8 gb ddr ram expendable up to 16 gb, itb, hdo(t2qorpm)2st antiglare led display with fhd (1920x1060) integrated hd graphics & webcam, 2xusb, 3.0 2xusb, 2.0 cardreader. audio part vgnhdmi/dp port10x100, 1000mcomdilant lan usb keyboard & mouse internalspl. connectivity bo2 11b/g/n/ac pl windows etec. with three years onsite warranty (ii) 650va offline ups system with 12vx7ahx2nos. 158vah/smf battery to provide 20 min. battery backup with three year warranty on ups and battery (iii) cannon/hp laser printer preferably lbp 2900b or hp mfp 1126nw, augmentation of existing 11/0.4 kv 25 kva s/stn singnahar to 63 kva in section pukhri-erection part, 11/0.4 kv, 63 kva distribution transformer ( outdoor type) from approved vendor of hpsebl, acsr conductor 6/1/3.35, 50 sq.mm, pipe earthing set i/c coal, charcoal, salt, surge arrester, 9 kv station class (porcelain type), muffs with concrete filling for existing poles in structire, lt distribution panel box with mccb for 63 kva dtr, aluminium paint, lt pvc cable 3.5 core 120 sq. mm, transportation of distribution transformer ( new capacity dtr from road site to site of work & dismanteled from site of work to road site) a/w mechanical transportation to and from final location

Central Government/Public Sector

CTN :40271788 Due date: 05 Jun, 202505 Jun, 2025 NA
Tender For corrigendum : procurement of post insulator for 66kv transmoission line of ntpc laraproject

corporations/Associations/Others

CTN :40251998 Due date: 02 Jun, 202502 Jun, 2025 8.58 Lacs
Tender For corrigendum : work of dog conductor to panther conductor conversion with replacement of conductor, hardware and insulator of 66kv rajuvadia ori line under getco achhalia tr division approved under r&m 2025-26 under bharuch tr circle

CTN :40504944 Due date: 08 Jun, 202508 Jun, 2025 NA
Tender For retender 3'rd call for the work of cleaning of insulator string by cold line chemical washing of various 400 kv line under jurisdiction of 400 kv r.s. division lamboti.