Tender For supply of miscellaneous electrical items for colony maintenance in shaktipuram colony, chinyalisaur - g.i. m10 nut bolt & washer tvs make + c18f, double pole isolator 40 amp, heat shrinkable cable jointing kit 120 sq mm, ceiling rose, single pole mcb 6 amp, mcb 63 amp, 4 pole, 10ka, ac, 415v, 3ph 4 wire electronicenergymeter without ct, pvc gang box 6 way, 5a, fuse wire 10 amp (200 gram per roll), single pole mcb 16 amp, single pole mcb 20 amp, pvc gang box 2 way, 16a, single pole mcb 25 amp, single pole mcb 32 amp, pvc gang box 3 way, 5a, pvc gang box 4 way, 5a, rechargeable battery 9v, led tubelight 22w, twisted flexible wire 2c x 0.75 sq mm, piercing connector 3ph ab cable 95mm , led driver 45 90w light, led driver 90 150w light, fan regulator, fan condenser, led street light 45w, led panel 2x2 light 40w, baton holder
Tender For auction sale of depot miscellaneous scrap - 126004elec26b, 98414513, quantity- 12425 kgs. scrap condemned unserviceable electrical items consists of disconnecting and earthing device with single rotary and double rotary, kwh meters, starters, pump controller, surge suppressor, mcbs, mccbs, mmrs, mpcbs, fuses, switch assembly, ballasts, rotary switches, contactors, magnetic stems, on load change over switches, churning fans, carbon brushes, inverters, capacitors, plugs, sockets, electronicenergymeters, switches, relays, fuses, switch plate assembly, valves and other electrical items of various makes, types and sorts and sizes, full or broken, with or without attachments. approx gross weight- 12425 kgs. approx copper content- 424.468 kgs. approx aluminium content- 25.04 kgs. approx brass content- 39.04 kgs. approx stainless steel content- 1547.06 kgs. approx zinc content- 20.423 kgs. approx non-metallic(pvc/acrylic/elastomer) content- 684.717 kgs. approx ferrous and others- 9684.252 kgs. note- delivery by weighment basis only. special note- purchasers of electrical and electronic equipment covered under e-waste rule 2016 in its schedule i should have registration from central pollution control board new delhi. the notification may be downloaded from the website of ministry of environment and forest notification g.s.r 472 [e] dated 10.06.2015 published in the gazette of india. locations- bin no- 6004 and 6005, in godown no- 6. hsn code- 85361010. gst- 18 percent. special note: overload of the carrying capacity of the vehicle will not be permitted at the time of taking delivery as per motor vehicle act 1988.
Tender For tender for supply of periodical maintenance and operation of electrical and mechanical installations involving operation , repairs and maintenance , attending to complaints/faults/ breakdowns and taking rectification action , ensuring serviceability/satisfactory working condition of the systems , carrying-out preventive maintenance , maintenance of records/ documents etc. under this contract on all working days including saturdays , sundays and holidays as per tender specifications , terms & conditions by providing/engaging following minimum number of man power i/c reliever. (a) highly skilled (sr. supervisor) - 1 nos. (b) highly skilled (supervisor) - 1 nos. (b) skilled data entry operator - 1 nos. (c) skilled technician - 14 nos. i/c relievers (d) unskilled helper - 14 nos. i/c relievers total minimum manpower i/c reliever- 31 nos. note- relievers shall do duty of electrician//helper as per site requirement. , carriage of diesel (4 drums 200 ltr each) from petrol pump (any petrol pump among located in kushinagar as decided by eic-aai) to the sub station (dg set room) which includes hiring of vehicle loading & unloading of empty and oil filled drums at site. note - empty drum will be provided by aai. , servicing of l&t make , model u-power omega air circuit breaker 630/800 a through l&t service engineer / l&t authorized service engineer including carrying out of following works- racking out & removal of acb from electrical panel , cleaning all parts for dust deposits foreign particles etc , degreasing the various parts of acb. cleaning all parts with cleaning agents such as crc 2-26 checking the various relay/protection settings and other setting of acb contacts , releases etc , checking the hardware for wear & tear , checking of termination & tightness , checking for all hardwares for its presence , replacement of spares / accessories for defective / worn out items (supply of spares / accessories required for healthiness of acb are in aai scope) , regreasing of the acb parts as recommended by oem , refixing the acb , testing and observance for normal operation of acb complete as required. note - service report to be submitted in l&t letterhead / l&t authorise service dealer letter head. , one time servicing , maintenance , testing , overhauling of complete out door type package/ compact sub-station of m/s c & s make through oem service er. or oem authorised dealer /service er.only as per the oem recommendation and scope of work of tsc/ scc of the contract. pss is comprising of following- ht panel - 12kv , 630 a , 21ka/3sec , 2way non extensible sf6 insulated rmu comprising of 01 nos. 630a manual load breaker switch and 01 no. 630a manual vaccum circuit breaker. transformer - 11kv/0.433kv , 400 kva oil type transformer -01 nos. lv componenet - 4 p , 630a , drawout acb - 01 no. 3p 400a mccb for capacitor panel capacitor panel - apfc 200kvar capacitor panel- 01 nos. pss is comprising all above i/c metering , relay etc complete. oem service er. has to submit the relay calibration report along with service and maintenance report of transformer , rmu , ht & lt panel and capacitor panel i/c healthiness report after service and other report if any as per oem recommendations complete. , carriying out the dehydration of transformer oil of 400 kva transformer (make - kotson) in 400 kva c &s pss at site i/c transportation of dehydration machine , di-electric strength test (bdv value) of oil before and after dehydration at site and submisstion of report as per requirement. note - the transformer having capacity of 330 ltrs of tranformer oil. , supply of new transformer oil conforming to is-335 in non-returnable barrel as per requirement. , one time servicing , maintenance , testing , overhauling of complete outdoor type package/compact sub-station of m/s sudhir power make through oem service er or oem authorised dealer /service er.only as per the oem recommendation and scope of work of