Get complete information related to latest Ent Equipment Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Ent Equipment Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Ent Equipment Tenders.
Tender For corrigendum : e- 288/mmgpa/ ent equipments - ent operating microscope , two set of micro drill with two head pieces and burr head, two sets of micro ear surgery instrument, otacaustic emission analyser (oae), puretone audiometer , impedance audiometer
Tender For corrigendum : supply of harmonic 36 mm lap probe har 36 , harmonic 36 mm har 1136 , harmonic hand piece hp054 , bed for ercp fluoro , stent pusher , cbd pancreatic plastic stents double pigtail 10 by 10f , cbd pancreatic plastic stents double pigtail 10 by 7 f , cbd pancreatic plastic stents double pigtail 7 by7f , cbd pancreatic plastic stents straight 5 by 5 , cbd pancreatic plastic stents straight 7 by 5 , cre gun for cre baloons , precut spincterotome , lead aprons , hemoclips large 16 mm , 6f by 7 point 6 fr ureteroscope karlstorz , 7 fr flexible uretroscope biorad with video processor , 20 fr cystoscope shealth with bridge olympus , long formalin sterilization chamber for endoscopes , long cidex disinfection tray for endoscopes , scurb trollies for in house transportation of equipment , parrafin wax in pellet form for pathology lab
Tender For e-tender for procurement of some consumable items for two years from the date of award of contract (aoc)- disposable surgeons full wrap around gown specification: the products should be eo sterilized & ready to use, arterial lines : polyethylene/ polyeurathene arterial lines (singlelumen 18g - length-15cm/10cm/8cm/ 6cm/4cm) with seldinger technique, arterial lines : polyethylene/ polyeurathene arterial lines (singlelumen 22g - length-15cm/10cm/8cm/6cm/4cm) with seldinger technique, blood pressure equipment, sphygmomanometer, digital with pulse recording and 100 reading memory, blood transfusion set, sterile, disposable • medical grade non toxic and dehp free tubing with 200 micron filter • clear, transparent, flexible molded drip chambers with fix fluid filters and bacteria retention air vent transparent spike for easy piercing • efficient roller control for better flow control • molded “bulb type” injection site for extra medication • approximately 20 drops, l ml dw • sterilization by eto or more advance process. leur lock., bipap mask with bronchoscopy port along with accessories detachable & autoclavable vented / non vented swivel connector., blood cardioplegia device - adult - heat exchanger pleatal type. priming volume of heat exchanger : <30 ml . integrated heat exchanger with bubble trap. assemble with class vi implant tested tubing. high cooling eficiency. eassy set up and priming. outlet comnnection 1/4" built in bridge for choice of 100 % blood and 100 % cardiopledgia solution delivery., blower mister kit : comfortable hand grip with a 6.5" (16.5 cm) malleable stainless steel shaft for ease of positioning near the surgical site.the soft; silicon tip contains a plastic tube which carries saline to the tip ., burret set (100ml), c-arm cover 2 part materials-plastic, sterile pack, ready to use., catheter mount, collapseble catheter mount with bronchoscopy and suction port, cervical spinal locking plate assorted size with required screw, material – titanium, close suction with non returnable valve and terbojet clining system. sizes 10,12,14 fr., connector - straight assorted sizes - pvc material, sterile pack, coronary shunts assorted size : bevelled ultra-soft tip , obstruction -free flow path , large atraumatic sealing surface & flexible shaft., cvc3 fr. with anti kinking nitinol guide wire (paediatric)- 6cm/l0cm/15 cm with long shelf life >5 years. thermosensitive polyurethane double lumen paediatric cvc with accessories., cvp transducer : integrated unit for clinical accuracy. dual mode of flushing controlled squeeze and snap-tab. completely transparent for easy priming and debubbling with flushing of 3 cc / hr or without flush. easy zeroing. standard closed loop sampling kit / double. [note : compatible cable, cvp/ibp transducer clamp (reusable) will be supplied at free of cost ], cvp transducer compatible with arterial pulse contour monitor (disposable single use) [note : compatible cable, cvp/ibp transducer clamp (reusable) will be supplied at free of cost ], disposable sterile full gown with eye protection sterile disposable prepackaged, disposable ventilator circuit with single water trap. should be tidel volume range from 200 ml to 1500 ml. should be minimal deade space 55 ml. medical grade pe. connector 15/22 mm m/f for y piece, connector 15/22 mm m/f for ett & mask. standard length . 6ft. or expandable length., dome kit with flushing system. • should be single line monitoring dome. • should be measure invasive pressure., digital foetal doppler, eye drape • sheet size: 80 x 75 cm - 90 x 75 cm • adhesive area: 9 x 7 cm with 6 eye lid holders • drainage pouch of transparent pe film • eto (eo) sterile, face mask , disposable ,should be manufactured from non woven poly prop fabric ,should be 3 ply construction,should have high bacterial filtration efficiency ,should be cor ners, length of string should be 40 cmheat sealed to keep 3 layers together ,standard size 17.5 x 9 cm, colour green / blue ,th
Tender For procurement of some consumable items - disposable surgeons full wrap around gown specification: the products should be eo sterilized & ready to use, arterial lines : polyethylene/ polyeurathene arterial lines (singlelumen 18g - length-15cm/10cm/8cm/ 6cm/4cm) with seldinger technique, arterial lines : polyethylene/ polyeurathene arterial lines (singlelumen 22g - length-15cm/10cm/8cm/6cm/4cm) with seldinger technique, blood pressure equipment, sphygmomanometer, digital with pulse recording and 100 reading memory, blood transfusion set, sterile, disposable medical grade non toxic and dehp free tubing with 200 micron filter clear, transparent, flexible molded drip chambers with fix fluid filters and bacteria retention air vent transparent spike for easy piercing efficient roller control for better flow control molded bulb type injection site for extra medication approximately 20 drops, l ml dw sterilization by eto or more advance process. leur lock., bipap mask with bronchoscopy port along with accessories detachable & autoclavable vented / non vented swivel connector., blood cardioplegia device - adult - heat exchanger pleatal type. priming volume of heat exchanger : <30 ml . integrated heat exchanger with bubble trap. assemble with class vi implant tested tubing. high cooling eficiency. eassy set up and priming. outlet comnnection 1/4" built in bridge for choice of 100 % blood and 100 % cardiopledgia solution delivery., blower mister kit : comfortable hand grip with a 6.5" (16.5 cm) malleable stainless steel shaft for ease of positioning near the surgical site.the soft; silicon tip contains a plastic tube which carries saline to the tip ., burret set (100ml), c-arm cover 2 part materials-plastic, sterile pack, ready to use., catheter mount, collapseble catheter mount with bronchoscopy and suction port, cervical spinal locking plate assorted size with required screw, material titanium, close suction with non returnable valve and terbojet clining system. sizes 10,12,14 fr., connector - straight assorted sizes - pvc material, sterile pack, coronary shunts assorted size : bevelled ultra-soft tip , obstruction -free flow path , large atraumatic sealing surface & flexible shaft., cvc3 fr. with anti kinking nitinol guide wire (paediatric)- 6cm/l0cm/15 cm with long shelf life >5 years. thermosensitive polyurethane double lumen paediatric cvc with accessories., cvp transducer : integrated unit for clinical accuracy. dual mode of flushing controlled squeeze and snap-tab. completely transparent for easy priming and debubbling with flushing of 3 cc / hr or without flush. easy zeroing. standard closed loop sampling kit / double. [note : compatible cable, cvp/ibp transducer clamp (reusable) will be supplied at free of cost ], cvp transducer compatible with arterial pulse contour monitor (disposable single use) [note : compatible cable, cvp/ibp transducer clamp (reusable) will be supplied at free of cost ], disposable sterile full gown with eye protection sterile disposable prepackaged, disposable ventilator circuit with single water trap. should be tidel volume range from 200 ml to 1500 ml. should be minimal deade space 55 ml. medical grade pe. connector 15/22 mm m/f for y piece, connector 15/22 mm m/f for ett & mask. standard length . 6ft. or expandable length., dome kit with flushing system. should be single line monitoring dome. should be measure invasive pressure., digital foetal doppler, eye drape sheet size: 80 x 75 cm - 90 x 75 cm adhesive area: 9 x 7 cm with 6 eye lid holders drainage pouch of transparent pe film eto (eo) sterile, face mask , disposable ,should be manufactured from non woven poly prop fabric ,should be 3 ply construction,should have high bacterial filtration efficiency ,should be cor ners, length of string should be 40 cmheat sealed to keep 3 layers together ,standard size 17.5 x 9 cm, colour green / blue ,there should be a string each at all four, flexible annuloplasty ring - assorted sizes, complete
Tender For e-tender for procurement of some consumable items for two years from the date of award of contract (aoc)- disposable surgeons full wrap around gown specification: the products should be eo sterilized & ready to use, arterial lines : polyethylene/ polyeurathene arterial lines (singlelumen 18g - length-15cm/10cm/8cm/ 6cm/4cm) with seldinger technique, arterial lines : polyethylene/ polyeurathene arterial lines (singlelumen 22g - length-15cm/10cm/8cm/6cm/4cm) with seldinger technique, blood pressure equipment, sphygmomanometer, digital with pulse recording and 100 reading memory, blood transfusion set, sterile, disposable • medical grade non toxic and dehp free tubing with 200 micron filter • clear, transparent, flexible molded drip chambers with fix fluid filters and bacteria retention air vent transparent spike for easy piercing • efficient roller control for better flow control • molded “bulb type” injection site for extra medication • approximately 20 drops, l ml dw • sterilization by eto or more advance process. leur lock., bipap mask with bronchoscopy port along with accessories detachable & autoclavable vented / non vented swivel connector., blood cardioplegia device - adult - heat exchanger pleatal type. priming volume of heat exchanger : <30 ml . integrated heat exchanger with bubble trap. assemble with class vi implant tested tubing. high cooling eficiency. eassy set up and priming. outlet comnnection 1/4" built in bridge for choice of 100 % blood and 100 % cardiopledgia solution delivery., blower mister kit : comfortable hand grip with a 6.5" (16.5 cm) malleable stainless steel shaft for ease of positioning near the surgical site.the soft; silicon tip contains a plastic tube which carries saline to the tip ., burret set (100ml), c-arm cover 2 part materials-plastic, sterile pack, ready to use., catheter mount, collapseble catheter mount with bronchoscopy and suction port, cervical spinal locking plate assorted size with required screw, material – titanium, close suction with non returnable valve and terbojet clining system. sizes 10,12,14 fr., connector - straight assorted sizes - pvc material, sterile pack, coronary shunts assorted size : bevelled ultra-soft tip , obstruction -free flow path , large atraumatic sealing surface & flexible shaft., cvc3 fr. with anti kinking nitinol guide wire (paediatric)- 6cm/l0cm/15 cm with long shelf life >5 years. thermosensitive polyurethane double lumen paediatric cvc with accessories., cvp transducer : integrated unit for clinical accuracy. dual mode of flushing controlled squeeze and snap-tab. completely transparent for easy priming and debubbling with flushing of 3 cc / hr or without flush. easy zeroing. standard closed loop sampling kit / double. [note : compatible cable, cvp/ibp transducer clamp (reusable) will be supplied at free of cost ], cvp transducer compatible with arterial pulse contour monitor (disposable single use) [note : compatible cable, cvp/ibp transducer clamp (reusable) will be supplied at free of cost ], disposable sterile full gown with eye protection sterile disposable prepackaged, disposable ventilator circuit with single water trap. should be tidel volume range from 200 ml to 1500 ml. should be minimal deade space 55 ml. medical grade pe. connector 15/22 mm m/f for y piece, connector 15/22 mm m/f for ett & mask. standard length . 6ft. or expandable length., dome kit with flushing system. • should be single line monitoring dome. • should be measure invasive pressure., digital foetal doppler, eye drape • sheet size: 80 x 75 cm - 90 x 75 cm • adhesive area: 9 x 7 cm with 6 eye lid holders • drainage pouch of transparent pe film • eto (eo) sterile, face mask , disposable ,should be manufactured from non woven poly prop fabric ,should be 3 ply construction,should have high bacterial filtration efficiency ,should be cor ners, length of string should be 40 cmheat sealed to keep 3 layers together ,standard size 17.5 x 9 cm, colour green / blue ,th
Tender For state plan-state plan 2025-2026-procurements of equipments for wtps-supply and installation of water quality testing equipments at wtps under ws section 1 attingal-general civil work-general civil work - purchase of jar test apparatus, od229090/2025-2026:supply and installation of the jar test apparatus must meet the following specifications. no. of. stirrers -6 minimum, rpm- 25 to 200 rpm or better, capacity of single stirrer unit-, control—digital control (digital timer & rpm counter), stirrer paddle material (with appropriate corrosion protective coating) - stainless steel, power single phase (220 - 240 volts), illumination—fluorescent tube such that illumination should not contribute heat to the system and entire equipment must have a minimum warranty period of two years, purchase of ph meter, od229087/2025-2026:supply and installation of bench top ph meter must with the following specifications: (a) regarding ph: the range must be between 0.00 to 14.00 ph or better, the resolution 0.01 or better, the accuracy 0.02 ph or better, the calibration points should be atleast 3 points, buffer option should be suitable for standard buffers. (b) regarding mv: range 0 to 1999 mv, resolution 1 mv or better, accuracy mv or better (c) regarding temperature: range 0.0 to 99 degrees celsius or better, resolution should be 0.1 degrees celsius or better, and accuracy of 0.5 degrees celsius or better. (d) the electrode of the ph meter must be a single junction, body plastic/unbreakable material, gel-filled electrode, and atc probe, and the electrode stand should also be provided by the supplier. (e) ph meter must also have lcd/led display, a dual display of ph or mv with temperature, with auto buffer recognition, offset/slope should be displayed, power 230v 10%, must provide a minimum of 100 ml of buffer solutions of ph 7.0, ph 4.0, and ph 9.2. the supplier must provide all accessories for smooth functioning of the equipment and a hard copy of the user manual with instrument specifications. the ph meter must have a minimum warranty of one year for the meter and a minimum of six months for the electrode. the calibration at the time of the installation must be done by the supplier., purchase of conductivity-tds meter, od229088/2025-2026:supply and installation of conductivity - tds meter with conductivity range of at least 0.1 s to100 ms, resolution : 0.001 s and tds range of 0.1 ppm to 100 ppt , temperature : 0 degree celsius to 1000 degree celsius (auto / manual), readout : 7 digits led (3 digits for temp. and 4 digits for cond./tds), printer interface for 80 column d.m. printer with minimum one year warranty
Tender For tender for ent equipments - ent equipments, fess set and nasal bone fracture, bera with assr, direct laryngoscope set, micro motor drilling system