Get complete information related to latest Ent Equipment Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Ent Equipment Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Ent Equipment Tenders.
Tender For corrigendum : e- 288/mmgpa/ ent equipments - ent operating microscope , two set of micro drill with two head pieces and burr head, two sets of micro ear surgery instrument, otacaustic emission analyser (oae), puretone audiometer , impedance audiometer
Tender For state plan-state plan 2025-2026-procurements of equipments for wtps-supply and installation of water quality testing equipments at wtps under ws section 1 attingal-general civil work-general civil work - purchase of jar test apparatus, od229090/2025-2026:supply and installation of the jar test apparatus must meet the following specifications. no. of. stirrers -6 minimum, rpm- 25 to 200 rpm or better, capacity of single stirrer unit-, control—digital control (digital timer & rpm counter), stirrer paddle material (with appropriate corrosion protective coating) - stainless steel, power single phase (220 - 240 volts), illumination—fluorescent tube such that illumination should not contribute heat to the system and entire equipment must have a minimum warranty period of two years, purchase of ph meter, od229087/2025-2026:supply and installation of bench top ph meter must with the following specifications: (a) regarding ph: the range must be between 0.00 to 14.00 ph or better, the resolution 0.01 or better, the accuracy 0.02 ph or better, the calibration points should be atleast 3 points, buffer option should be suitable for standard buffers. (b) regarding mv: range 0 to 1999 mv, resolution 1 mv or better, accuracy mv or better (c) regarding temperature: range 0.0 to 99 degrees celsius or better, resolution should be 0.1 degrees celsius or better, and accuracy of 0.5 degrees celsius or better. (d) the electrode of the ph meter must be a single junction, body plastic/unbreakable material, gel-filled electrode, and atc probe, and the electrode stand should also be provided by the supplier. (e) ph meter must also have lcd/led display, a dual display of ph or mv with temperature, with auto buffer recognition, offset/slope should be displayed, power 230v 10%, must provide a minimum of 100 ml of buffer solutions of ph 7.0, ph 4.0, and ph 9.2. the supplier must provide all accessories for smooth functioning of the equipment and a hard copy of the user manual with instrument specifications. the ph meter must have a minimum warranty of one year for the meter and a minimum of six months for the electrode. the calibration at the time of the installation must be done by the supplier., purchase of conductivity-tds meter, od229088/2025-2026:supply and installation of conductivity - tds meter with conductivity range of at least 0.1 s to100 ms, resolution : 0.001 s and tds range of 0.1 ppm to 100 ppt , temperature : 0 degree celsius to 1000 degree celsius (auto / manual), readout : 7 digits led (3 digits for temp. and 4 digits for cond./tds), printer interface for 80 column d.m. printer with minimum one year warranty
Tender For tender for ent equipments - ent equipments, fess set and nasal bone fracture, bera with assr, direct laryngoscope set, micro motor drilling system
Tender For providing of custom bid for services - internal & external cleaning of entire equipments of various stations in boiling house & centrifugal house
Tender For corrigendum : supply of schedule iv (x-ray films, chemicals, e. c. g. rolls, materiels etc.) - schedule iv (x-ray films, chemicals, e. c. g. rolls, materiels etc.), polyster base round corner x-ray films (8" x 10") green sensitive, blue base with base fog less than or equal to 0.23 & dmax not less than 3.10 interleaved. the density values should be met at developer temperature 32 c to 35 c, polyster base round corner x-ray films (10" x 12") green sensitive, blue base with base fog less than or equal to 0.23 & dmax not less than 3.10 interleaved. the density values should be met at developer temperature 32 c to 35 c, polyster base round corner x-ray films (12" x 15") green sensitive, blue base with base fog less than or equal to 0.23 & dmax not less than 3.10 interleaved. the density values should be met at developer temperature 32 c to 35 c, dental x-ray films intraoral periapcal the density values should blue base with base fog less than or equal to 0.20 & dmax not less than 3.10 the density values should be met at developer temperature 32 c to 35 c, liquid developer replenisher for automatic processor (starter solution, if recommended by the manufacturer, should also be supplied), ( price of item no. 5 and item no. 6 will be considered as a unit), liquid fixer hardner for automatic processor ( price of item no. 5 and item no. 6 will be considered as a unit), inj. meglumine diatrizoate sodium diatrizoate iodine content 365-375 mg/ml in 20 ml. ampoule/vial, pigtail angiography catheter with multiple side holes length 65 to 75 cm 5f, inj. gadolinium based contrast for mri for liver/liver specific (should provide details of compound being hepatobiliary specific), inj. gadolinium based contrast for mri for general use, inj. gadolinium based contrast for mri for angiography, disp lure lock syringes 3 ml. for glue injection, disp lure lock syringes 1 ml. for glue injection, x-ray folders laminated 250 gsm 14 1/2" x 17 ", dual pack 200 ml syringe with aspirator, "y" shaped coiled tube y-tube sterile, non-pyrogenic (minimum 300 psi & above) compatible with dual head pressure injector ( lf/medrad/ sea crown / spectra / apollo), extension "y" shaped coiled tubing for injector 150 cms. (-5 or +15cm) low pressure (minimum 300 psi & above), dual disposable syringes (60 to 65 ml each) with "y" or "t"shaped coiled tube connecting tubes small spike for contrast and large spike for saline compatible with mri injector (lf or medrad)., one way stopcock (high pressure), low pressure extension "y" or "t" shaped coiled tubing min. 150cms (-5 or +15 cms) with coiled connecting tubes & small spike for contrast & large spike for saline for medical mri injector., flavoured, ionic, water soluble, oral contrast iodine content 240-250 mg/ ml. in 30 ml, bernstein catheter 4 f 100 cm, bernstein catheter 5 f 100 cm, chiba needle 21 g 15 cms length, chiba needle 22 g 15 cms length, disposable c t scan pressure injector syringes (190 ml syringe + quick fill tube) for bayer medrad salient injector (toshiba / canon), extension "y" shaped coild tube adapter dual check valves (minimum psi 300 & above), nonionic iodixanol isoosmolar, 320 mg 50 ml, disposable mri syringes kit for 65/115 mr injector system 65 ml contrast syringes and 115 ml ns syringes with connecting tubing combo pack for spectris solaris medrad pressure injector, spring loaded fully automatic and semi automatic biopsy instrument with adjustable penetration depth of 18 mm and 25 mm. having trocar tip with dimpling on needle and fire ready indicator. 14 g & 10 cm in length, spring loaded fully automatic and semi automatic biopsy instrument with adjustable penetration depth of 18 mm and 25 mm. having trocar tip with dimpling on needle and fire ready indicator. 16 g & 10 cm in length, coil shape breast tissue marker with both front trigger & an alternate rear trigger, should be visible in ultrasound, mammography and mri, extension coiled tube with integr
Tender For corrigendum : supply of continous peripheral nerve block catheter. specification:1) 20 degree back cut echogenic needle 18g with x pattern engraved on first 20 mm from tip. 2) a double layer polyamide & poly urethane 50 mm catheter with 3 pairs of laser drilled holes tapered tip design (0.45x0.85x50 mm). 3) provision of single bolus shot with extension tubing, along with snap cap catheter connector. 4) 0.2 micron filter & 5 ml syringe. 5) pinpad fixation device & crocodile clip. 4) can be used for both pns machine and by ultrasound. 5) have to be compatible with existing b. braun nerve locator.[ ai(2025-26), item code-no: s61501, sl no.1662]
Tender For corrigendum : supply of continous peripheral nerve block catheter. specification:1) 20 degree back cut echogenic needle 18g with x pattern engraved on first 20 mm from tip. 2) a double layer polyamide & poly urethane 50 mm catheter with 3 pairs of laser drilled holes tapered tip design (0.45x0.85x100 mm). 3) provision of single bolus shot with extension tubing, along with snap cap catheter connector. 4) 0.2 micron filter & 5 ml syringe. 5) pinpad fixation device & crocodile clip. 4) can be used for both pns machine and by ultrasound. 5) have to be compatible with existing b. braun nerve locator.[ai(2025-26), item code-no: s61502, sl no.1663]