Tender For srphc82281240-coronary drug eluting stents with (1) stent on cobalt chromium alloy or platinum chromium alloy. (2) stent with coating of polymer carrier for active drug ( sirolimus, everolimus or zotarolimus shown to be effective in preventing neo-intimal hyperplasia) (3) stent diameter should be from 2.5mm to 4mm and length of the stent should be 12mm to 48mm. (4) the strut thickness should be 91 micron or less. (5) stent delivery system should be monorail (single operator exchange or rapid exchange). (6) stent should be compatible with 5fr guiding catheter (7) stent design should be open cell type. (8) stent should be approved by dcgi. the copy of dcgi approval shouldbe enclosed in the tender bid. (9) the long term efficacy and safety of the stent in terms of target vessel revascularisation (tvr) and in-situ thrombosis (ist) should be documented / published in peer reviewed scientific journals. (10) the documents related to the efficacy and safety of the stent should be only for the brand that is offered in the tender bid (11) the manufacturer/supplier should submit proof of supply of the stent toa major government institute.[quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For srphc82281215-coronary drug eluting stents (1) with single wire design with cobalt alloy shell and platinum iridium core (2) stent with coating of biolinx polymer carrier for active drug zotarolimus shown to be effective in preventing neo-intimal hyperplasia (3) stent diameter should be from 2 mm to 5mm and length of the stent from 8 mm to 38 mm. (4) the strut should be round with thickness ranging from 81 to 91 microns (5) stent delivery system should be monorail (single operator exchange or rapidexchange). (6) stent should be compatible with 5fr guiding catheter (7) stent design should be open cell type. (8) stent should be approved by dcgi. the copy of dcgi approval should be enclosed in the tender bid. (9) five years efficacy and safety of the stent in terms of target vessel revascularisation (tvr) and in-situ thrombosis (ist) should be documented / published in peer reviewed scientific journals.(10) the documents pertaining to the efficacy and safety of the stent should be enclosed for the brand that is offered in the tender bid (11) the manufacturer/supplier should submit proof of supply of the stent to a major government institute. ]
Tender For supply of air intake duct and stone guard system work as per edt- 2871 , thrust stand and engine mounting area work as per edt-2871 , maintenance platform work as per edt-2871 , exhaust detuner work as per edt-2871 , locking and clamping as per edt-2871 , miscellaneous work as per edt- 2871 , protective coating as per edt-2871 , spares of critical system as per edt-2871 , supply of components and spares as per edt-2871
Tender For supply of micro catheter braided two tip marker steam shapeable tip, distal tip of at least 2.1 f, , 3 d self detachable neuro embolisation coils 5to8mm 5 to 20 cm length for framing , soft tip intracranial 6f guiding catheter for distal smooth navigation like neuron penumbra , stent neuro, self expandable for intracranial aneurysm neck remodeling, , flow diversion embolisation device for intracranial aneurysm like silk vista surpass pipeline derivo , micro guide wire with hydrophilic coating floppy tip, of at least 180 cm length and 0.014 diameter , micro guide wire steel construction hydrophilic coating shapeable tip 0.008 inch diameter at least 180 cm length , micro catheter lto110 130 cm, od distal 2.4 2.7f for peripoheral intervention, glide m coating, preloaded with 0.021 , haemostatic sponge gelatin 80 mm long, 50mm broad, 10 mm thick. , semiautomatic core biopsy gun set with 02 throw lengths of 10mm and 20 mm in a single device , stent carotid self expendable , dual layered , oepn cell with outer prfe mesh such as ctoguard from inspired md , percutaneous angioseal vascular access closer system based on intra vascular collagen plug , polyvinyl alcohol particles 150to250 microns , polyvinyl alcohol particles 250to350 microns , polyvinyl alcohol particles 350to500 microns , polyvinyl alcohol particles 500to750 microns , guidewire, amplatz ultra stiff, 0.035 inch diameter, 260 cm or more length, available with 1cm, 3cm and 6 cm floppy tip segment , cobra 1 c1 visceral braided torque control catheter 5.0 french 65 cms long permitting 0.035 inch guide wire. , kampa accepss catheter 5f 65 cm length , micro catheter braided two tip marker steam shapeable tip, distal tip of at least 2.1 f, suitable for neurointervention , 3 d self detachable neuro embolisation coils 5to8mm 5 to 20 cm length for framing of ruptured aneurysm like target 360 stryker , stent neuro, self expandable for intracranial aneurysm neck remodeling, 4.5 x 20 mm such as lvis from microvention. , micro catheter lto110 130 cm, od distal 2.4 2.7f for peripoheral intervention, glide m coating, , polyvinyl alcohol particles 150 to250 microns
Tender For supply, installation and commissioning of 01 set powder coating system (comprising of 1 no.heat chamber, 1 no. powder spray booth and 2 nos. heavy duty powder gun) as per attached specification. [ warranty period: 30 months after the date of delivery ] ]
Tender For supply of obliqpurple colour for 60-65mm laprosco , set of eight reload cartridges blueobliqgreenobliqpurple for 40-45 mm lapa , set of eight reload cartridges gold for 60mm laparoscopic powered , sodium perborate parasafe powder , spring loaded disposable core biopsy gun 14g 16 cm long standard g , spring loaded disposable core biopsy gun 16g 16 cm long standard co , spring loaded disposable core biopsy gun 18g x 20 cm long stan , sterile nitrile powder free micro textured with long cuff 280mm size 7 , sterile nitrile powder free micro textured with long cuff 280mm size 7.5 , sterile oxygenated regenerated cellulose absorbable hemostat surgicel , sterile synthetic absorbable polygalactin 910 with antibacterial coati , steristrps 1obliq2 inch x 4 inch skin closure , synthetic absorbable green monofilament polyglyconate suture size , disposable clip applicator 5mm with 360 degree rotation , titanium haemostatic clips size large with two applicators and 500 c , triple layered anti microbial foam dressing with silver sulphate , triple layered antimicrobial dressing with silicone sulphate sil , trucut biopsy guns , universal reload for new titanium linear cutter 75 mm selectable s , harmonic ace shears 23 cm for ultrasonically activated cutting an , sterilised braided coated polyglactin 910 violet free tie size 3obliq0 lengt , waterproof opsite dressing with pad 5 x2.5 cm , waterproof opsite dressing with pad 8x6 cm , harmonic acewith shears hand piececurved tip. 5mm shaft diameter 3 , sterilized disposable non-woven fabric wraparound procedure gown , non- absorbable polymer ligating clips large , wound manager medium fistula and post op wound management system , harmonic hd1000i shears 20 - 23 cm with 15 - 18mm blade length and m , 3d anatomically shaped light-weight polypropylene mesh for , 3d anatomically shaped light-weight polypropylene mesh for laparoscopic i , harmonic hd1000i shears 36 cm with 18mm blade length and maryland , 5 mm laparoscopic clip applicator preloaded 20 clips , absorbable poliglecaprone suture 2obliq0 with undyed alloy needle 1obliq2 circle , adhesive five layered anti microbial foam dressing with silver sulphat , adhesive water proof transparent dressing 1.5 x 1.75 inch , chlorhexidine hand disinfectant composition isopropanol alcohol , antibacterial triclosan impregnated polydioxanone loop suturesize , hemolockobliq polymer single clip angled applier laparoscopic reusabl , antimicrobial five layered highly absorbant sacrum shaped dressing w , hemolockobliq polymer single clip applier laparoscopic reusable for extr , aquacel foam ag adh three layer adherant foam dressing com , barrier spray 50 ml , urostomy kit complete with convexobliqmouldable , bioresorbale fully absorbable dual mesh assorted size , black braided silk size 0 alloy needle 1obliq2 circle round body allo , black braided silk size 1 3obliq8 circle cutting alloy needle needle size , dispo laparo atraumatic bowel grasper 5 mm fenestrated straigh , bp blade assorted size10 11 12202223 each equlqty , braided polyglactin no 1 120 cm 1obliq2 circle round body needl , braided polyglactin no 1 90 cm 1obliq2 circle round bod , braided polyglactin no 2obliq0 90 cm 1obliq2 circle reverse cu , braided polyglactin size 1obliq0 90-120cm 1obliq2 circle round b , braided polyglactine no 3obliq0 3obliq8 circle round body needl , braided silk suture for free tie size no 1 each foil contains 2x75 , braided silk suture for free tie size 2obliq0 each foil contains 2x76 , braided silk suture for free tie size 3obliq0 each foil contains 2x75cm , disposable laparoscopic bipolar grasping //bid details 3 / 143 forceps and scissors size , dispo laparoscopic bladeless optical trocar 05 mm x 100 mm comp , disposable laparoscopic preloaded multifire large titanium clip appli , disposable laparoscopic smoke filtration system , disposable laparoscopy camera cover , disposable monopolar cautery tip with ptfe coating length 2 inch , chlorhexidine iv securement dressing 7
Tender For supply of self expandable closed cell carotid stents tapered 8-6mm into 40mm , embolic protection device for carotid intervention with basket design and capability of passing microguidewire of choice independent of device , hypersoft detachable 3d neuromicrocoil 2-8 mm diameter - assorted length , compleinto finish coil 3d shape 10 system eintotra soft coil for brain aneurysm, size range of 1mm to 5mm , 3d soft detachable neuro embolisation coils 2 - 6 mm, 4 to 15 cm length for framing of ruptured aneurysm , embolization 3d coil od 0point0125inch, 0point0135inch, 0point0145 , embolization 3d coil, 6mm diameter and 10by15by20 cm length, mechanical detachment system , guiding catheter 6f 0point070 105 cm length , micro guidewire with hydrophilic coating for neurointervention , liquid embolization agent onyinto 18, 34 with dmso , liquid lipidol as diluent for nbca 10mlpoint , n-butyl cyanoacrylate 0point5ml inj , kampi angiography catheter 40 to 65 cm length, 4by5 fr permitting , micropuncture set 4by5 f , 6fr highly fleintoible intracranial support catheter for aneurysm coiling , neurovascular self expandable nitinol stent, fully deployable, completely retrievable , microcatheter for super selective catheterization with 165cm usable length , straight tip hybrid braid, dmso compatible microcatheter with two tip , pushable 0point018inchpushable 0point018inch coils, 3-6mm for peripheral embolisation , pushable embolization coils 0point018inch 2by3by4mm diameter into 3cm or longer , polyvinyl alcohol particles 500-700 microns , polyvinyl alcohol particles 350-500 micronspoint , biliary self eintopanding metallic stents size 10mm into 10 cm , aspiration catheter for stroke intervention id 0point072inch,od 2point16mm with glide coating, 132 cm length , hydrophilic coated guide wires suitable for negotiating tortuous vascular anatomy with j curve tip of 0point035inch diameter and 150 cms length , self expanding covered stent graft for peripheral vascular intervention 5by6by7mm diameter into 30mm or more length , transjugular liver access set , toner cartridge black w20204by416a , reperfusion catheter for stroke management with large id of 0point072inch and 132 cm length with hi-flow aspiration tubing , pcn dilator set //bid details 2 / 31
Tender For srphc82281210-coronary drug eluting stents (1) single wire technology on cobalt based alloy platform (2) stent with coating of biolinx polymer carrier for active drug zotarolimus shown to be effective in preventing neo-intimal hyperplasia) (3) stent diameter should be from 2.25 mm to 4 mm and length of the stent from 12mm to 38 mm. (4) the strut thickness should be 81 micron or less. (5) stent delivery system should be monorail (single operator exchange or rapid exchange). (6) stent should be compatible with 5fr guiding catheter (7) stent design should be open cell type. (8) stent should be approved by dcgi. the copy of dcgi approval should be enclosed in the tender bid. (9) five years long term efficacy and safety of the stent in terms of target vesselrevascularisation (tvr) and in-situ thrombosis (ist) should be documented / published inpeer reviewed scientific journals.(10) the documents pertaining to the efficacy and safety of the stent should be enclosed for the brand that is offered in the tender bid (11) the manufacturer/supplier should submit proof of supply of the stent to a major government institute.[quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For srphc82281275-des-abbreviated dapt long -coronary drug eluting stents with (1) platinum chromium alloy (2) coating of bioabsorbable polymer carrier for activedrug everolimus shown to be effective in preventing neo-intimal hyperplasia) (3) stent diameter should be from 2.5mm to 4mm. the length of the stent should be from 12mm to 48 mm. (4) the strut thickness should be 91 micron or less. (5) stent delivery system should be monorail (single operator exchange or rapid exchange). (6) stent should be compatible with 5fr guiding catheter (7) stent design should be open cell type. (8) stent should be approved by dcgi. the copy of dcgi approval should be enclosed in the tender bid. (9) the long term efficacy and safety of the stent, the rates of in-stent restenosis (isr) and in-situ thrombosis (ist) should be documented / published in peer reviewed scientific journals. (10) safety of abbreviated (three month) dual antiplatelet therapy for high bleeding risk patients should be documented in peer reviewed journals. (11) the manufacturer/supplier should submit proof of supply of the stent to a major government institute. bis standards for the drug eluting stent are not available. (reference:bis catalogue ).[quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]