Get complete information related to latest Fan Control Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Fan Control Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Fan Control Tenders.
Tender For maintenance of point wiring, old unsv fan and geysers, db and light fittings with other connected items in otm and md accn at ghatkopar and vikhroli area under ge (n) santacruz mumbai - supply & fix including taking down sub main wiring with two run of 06 sqmm stranded copper conductor frls wire with one run of 06 sqmm stranded copper conductor as earth continuity conductor connected to common earth dolly including pvc fr heavy duty conduit of adequate size for housing the wires from main db to spn db complete all as specified directed by engr in charge. note: two runs of 06 sqmm cable and one run of 06 sqmm cable with pvc conduit shall be measured as one length. make of cable- anchor/ havells/finolex /polycab/plaza of isi mark as approved by gemake of pvc conduit-anchor, modi, pressfit, precision, astral, panasonic anchor, polycab, presto plast, supreme, material and labour including taking down for sub main wiring with two single core 04 sqmm multi stranded copper conductor, frlsh pvc insulated, unsheathed cable including rigid non metallic pvc fr conduit heavy duty, isi marked of suitable size for sub main wiring including 04 sqmm frlsh pvc insulated and unsheathed stranded copper conductor as earth wire in surface/recess complete all as specified and directed. note:- two runs of 04 sqmm copper conductor cable, one run of 04 sqmm copper conductor and one run of pvc conduit will be measured as one unit.make of cable- anchor/ havells/finolex /polycab/plaza of isi mark as approved by gemake of pvc conduit-anchor, modi, pressfit, precision, astral, panasonic anchor, polycab, presto plast, supreme, material and labour including taking down for three phase sub main wiring with 4 single core 10 sqmm multi stranded copper conductor, frlsh pvc insulated, unsheathed cable including rigid non metallic pvc fr conduit heavy duty of adequate size, isi marked, not less than 25 mm dia for sub main wiring including 10 sqmm frlsh pvc insulated and unsheathed stranded copper conductor as earth wire in surface/recess complete all as specified and directed. note:- four runs of 10 sqmm copper conductor cable, one run of 10 sqmm copper conductor and one run of pvc conduit will be measured as one unit.make of cable- anchor/ havells/finolex /polycab/plaza of isi mark as approved by gemake of pvc conduit-anchor, modi, pressfit, precision, astral, panasonic anchor, polycab, presto plast, supreme, material and labour including taking down for point wiring with pvc insulated unsheathed single core multi stranded copper conductor 1.5 sqmm, 1100 volts grade cable, frlsh, passing through pvc casing capping/pvc conduit including all fittings and accessories for mounting of switches & sockets as required at site along with one run of pvc insulated unsheathed multistranded copper conductor cable 1.5 sqmm (green colour) frlsh as earth wire connected to earth dolly complete all as specified & as directed by engr-in-charge for one light point/ exhaust/wall/ceiling fancontrolled by one switch.make of cable- anchor/ havells/finolex /polycab/plaza of isi mark as approved by gemake of pvc conduit/ pvc capping-anchor, modi, pressfit, precision, astral, panasonic anchor, polycab, presto plast, supreme, all as per item no.4 above but one bell point controlled by one bell push., all as per serial no.4 here-in but for one light point controlled by two way switches (two way switch point wiring), all as per item no.4 but one 3 pin socket point 5 amps on independent board, all as per item no.4 but one 3 pin socket point 5 amps on same board, all as per item no 4 here-in-before but for one socket point 15 amp with 2.5 sq mm pvc unsheathed frlsh wire along with 2.5 sq mm green colour wire as earth continuity conductor connected to common earth dolly complete all as specified and as directed., all as per item no 4 here-in-before but for point wiring on independent board with 4sqmm copper cable and provision of 4sqmm pvc insulated frls cable 1100 volts grade with
Tender For procurement of spares for vfd - lntacvfd4-036 module (w/o brake), control board for lntacvfd4-036, flat cable control 18p for lntacvfd4-036, flat cable control 20p for lntacvfd4-036, fan assembly for lntacvfd4-036, es for lntac vfd-293 model, flat cable control 18p for lntacvfd4-293, flat cable control 20p for lntacvfd4-293, control board for lntacvfd4-293, power board, lntacvfd4-293, rectifier, lntacvfd4-293, fan assembly unit, 300mm axial, lntacvfd4-293, axial fancontrol pcb, lntacvfd4-293, capacitor 4000uf/415v, lntacvfd4-293, igbt 160kw with gate board lntacvfd4-293
Tender For corrigendum : providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - manufacturing unit; supply of id fan impeller with shaft for season 2026-27; service provider
Tender For corrigendum : maint repair replacement of point wiring replacement of led fittings repair maint of electric geysers building security lights exhaust fancontrol cables and connected items under ge 859 ews
Tender For procurement of greaves make gear box model u600, fluid coupling model fcu 10.5 and its spares for bottom ash eccentric crusher for ahp of unit no. 3 and 4 and pembril engineering make fluid coupling model 41scr 24x for id fan of unit no. 1 an 2 sgtps - greaves make gear boxes (model: u-600) of bottom ash eccentric crusher, greaves make gear box(model-u-600) complete assembly, worm shaft, wheel shaft, worm shaft oil seal, wheel shaft oil seal, greaves make fluid couplings (model: fcu-10.5) of bottom ash eccentric crusher, greaves make fluid coupling (model: fcu-10.5) complete assembly, impeller, casing nut, shaft, shaft distance piece, center spigot, casing bolts, baffle-1.5, driving bolts, driving plate, multi disc. unit, circlip ext., spherical collar, key, fluid coupling model 41scr 24x make pembril engineering for id fan of unit no. 1 & 2, variable scoop fluid coupling 41scr 24x make pembril engineering, .
Tender For procurement of ziehl make temperature controller and fancontroller installed in ritz make excitation transformers at 2x660 mw sstpp, stage-ii, dongalia, (m.p.).