Get complete information related to latest Fan Control Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Fan Control Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Fan Control Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :45740497 Due date: 22 Jul, 202622 Jul, 2026 49.00 Lacs
Tender For repair/maint of unserviceable internal wiring electrical fittings, ceiling/ exhaust fans/ summer appliances, day to day electrical complaints at d, e, f type officers qtrs, scientist hostel, dlomi and swimming pool at drdo township kbagh hyderabad

Central Government/Public Sector

CTN :45491026 Due date: 07 Jul, 202607 Jul, 2026 9.00 Lacs
Tender For corrigendum : maint repair of ceiling exhaust pedestal fan and geysers alongwith flameproof lights fans and allied works at various md accn at af stn singarsi under age i af singarsi

Central Government/Public Sector

CTN :45509043 Due date: 07 Jul, 202607 Jul, 2026 25.00 Lacs
Tender For corrigendum : repair/maintenance of internal electrification and summer appliances such as ceiling fans, exhaust fans, fresh air fans etc under ge (e) mathura

Central Government/Public Sector

CTN :45740428 Due date: 21 Jul, 202621 Jul, 2026 49.00 Lacs
Tender For 8331 repair rewinding of ceiling fan, exhaust fans, air circulator and certain allied items etc at lhs of lion gate of naval dockyard under ge (nw) kunjali, mumbai

Central Government/Public Sector

CTN :45713842 Due date: 18 Jul, 202618 Jul, 2026 36.00 Lacs
Tender For maintenance of point wiring, old unsv fan and geysers, db and light fittings with other connected items in otm and md accn at ghatkopar and vikhroli area under ge (n) santacruz mumbai - supply & fix including taking down sub main wiring with two run of 06 sqmm stranded copper conductor frls wire with one run of 06 sqmm stranded copper conductor as earth continuity conductor connected to common earth dolly including pvc fr heavy duty conduit of adequate size for housing the wires from main db to spn db complete all as specified directed by engr in charge. note: two runs of 06 sqmm cable and one run of 06 sqmm cable with pvc conduit shall be measured as one length. make of cable- anchor/ havells/finolex /polycab/plaza of isi mark as approved by gemake of pvc conduit-anchor, modi, pressfit, precision, astral, panasonic anchor, polycab, presto plast, supreme, material and labour including taking down for sub main wiring with two single core 04 sqmm multi stranded copper conductor, frlsh pvc insulated, unsheathed cable including rigid non metallic pvc fr conduit heavy duty, isi marked of suitable size for sub main wiring including 04 sqmm frlsh pvc insulated and unsheathed stranded copper conductor as earth wire in surface/recess complete all as specified and directed. note:- two runs of 04 sqmm copper conductor cable, one run of 04 sqmm copper conductor and one run of pvc conduit will be measured as one unit.make of cable- anchor/ havells/finolex /polycab/plaza of isi mark as approved by gemake of pvc conduit-anchor, modi, pressfit, precision, astral, panasonic anchor, polycab, presto plast, supreme, material and labour including taking down for three phase sub main wiring with 4 single core 10 sqmm multi stranded copper conductor, frlsh pvc insulated, unsheathed cable including rigid non metallic pvc fr conduit heavy duty of adequate size, isi marked, not less than 25 mm dia for sub main wiring including 10 sqmm frlsh pvc insulated and unsheathed stranded copper conductor as earth wire in surface/recess complete all as specified and directed. note:- four runs of 10 sqmm copper conductor cable, one run of 10 sqmm copper conductor and one run of pvc conduit will be measured as one unit.make of cable- anchor/ havells/finolex /polycab/plaza of isi mark as approved by gemake of pvc conduit-anchor, modi, pressfit, precision, astral, panasonic anchor, polycab, presto plast, supreme, material and labour including taking down for point wiring with pvc insulated unsheathed single core multi stranded copper conductor 1.5 sqmm, 1100 volts grade cable, frlsh, passing through pvc casing capping/pvc conduit including all fittings and accessories for mounting of switches & sockets as required at site along with one run of pvc insulated unsheathed multistranded copper conductor cable 1.5 sqmm (green colour) frlsh as earth wire connected to earth dolly complete all as specified & as directed by engr-in-charge for one light point/ exhaust/wall/ceiling fan controlled by one switch.make of cable- anchor/ havells/finolex /polycab/plaza of isi mark as approved by gemake of pvc conduit/ pvc capping-anchor, modi, pressfit, precision, astral, panasonic anchor, polycab, presto plast, supreme, all as per item no.4 above but one bell point controlled by one bell push., all as per serial no.4 here-in but for one light point controlled by two way switches (two way switch point wiring), all as per item no.4 but one 3 pin socket point 5 amps on independent board, all as per item no.4 but one 3 pin socket point 5 amps on same board, all as per item no 4 here-in-before but for one socket point 15 amp with 2.5 sq mm pvc unsheathed frlsh wire along with 2.5 sq mm green colour wire as earth continuity conductor connected to common earth dolly complete all as specified and as directed., all as per item no 4 here-in-before but for point wiring on independent board with 4sqmm copper cable and provision of 4sqmm pvc insulated frls cable 1100 volts grade with

Central Government/Public Sector

CTN :45505288 Due date: 07 Jul, 202607 Jul, 2026 NA
Tender For corrigendum : repair replacement of ber ceiling fans in certain otm accn offrs jcos ors md accn and other sanction work under ge south udhampur

Central Government/Public Sector

CTN :45733977 Due date: 21 Jul, 202621 Jul, 2026 10.00 Lacs
Tender For repair and maint to geyser, ceiling fans, exhaust fans and domestic ro etc work in certain building at hq 10 sector rr and 29 rr at pattan garrison under age (i) cif (k)

Central Government/Public Sector

CTN :45733902 Due date: 22 Jul, 202622 Jul, 2026 NA
Tender For repair and maintenance of summer appliances ceiling fans desert coolers water coolers refrigerators winter appliances, electric geyser solar water heater and other equipments at mil stn dappar under age(i) dappar

CTN :45717016 Due date: 11 Jul, 202611 Jul, 2026 NA
Tender For procurement of spares for vfd - lntacvfd4-036 module (w/o brake), control board for lntacvfd4-036, flat cable control 18p for lntacvfd4-036, flat cable control 20p for lntacvfd4-036, fan assembly for lntacvfd4-036, es for lntac vfd-293 model, flat cable control 18p for lntacvfd4-293, flat cable control 20p for lntacvfd4-293, control board for lntacvfd4-293, power board, lntacvfd4-293, rectifier, lntacvfd4-293, fan assembly unit, 300mm axial, lntacvfd4-293, axial fan control pcb, lntacvfd4-293, capacitor 4000uf/415v, lntacvfd4-293, igbt 160kw with gate board lntacvfd4-293

CTN :45532091 Due date: 04 Jul, 202604 Jul, 2026 NA
Tender For corrigendum : supply of 2x1818 kva inverter mandatory spares - supply of 2x1818 kva inverter mandatory spares., emparro cap 20/48, mb cap 20/24 buffer modul, mcs-b 5-110-240/24v power supply, miru-01, ofaa000gg25 - 25nhg000b-690;25a, 690v, iec000, 2218f/2tdh4o, 2218f/2tdh4ou, fan control box assembly, mersen fuse ac 1250a 690v - old code (3a, memory unit kit zmu-02, spxv010, cbh 335 c h 414 5r0, film capacitor, fuse 5a gpv;1500v;gpv;10,3x85;33.2a mgnd fuse, rev.a;contactor; af1250-30-22-68; 1260a(, rev.c;pcb kit;mgnd-01;assembly;, rev.b;cbhk 335 c 413 100r kt -mgnd resis, contactor gigavac p115cda, 1500v, 50a -grounding