Tender For srm etender annual maintenance contract (amc) for the demonstration, preventive maintenance as well as repairing work including supply of required spare of ctr make nitrogen injection fireprotection systems of various icts installed under, ehv o&m circle, akola. (1st call)
Tender For fire work at esic haryana. - (a) supplying, installation, testing and commissioning of electric driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required :(b) horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to is 1520.(c) suitable hp squirrel cage induction motor, tefc, synchronous speed 1500 rpm, suitable for operation on 415 volts, 3 phase 50 hz, ac supply with ip 55 protection for enclosure, horizontal foot mounted typewith class-f insulation, conforming to is-325.(d) m.s. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required.(e) suitable cement concrete foundation duly plasteredwith anti vibration pads., 2280 lpm at 70 m head, (a) supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required:(diesel driven pump)(b) horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to is 1520.(c) suitable hp, 1500 rpm water cooled with radiator, diesel engine conforming to relevant is standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulatedwith 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event offault with audio indications, painted with post office red colour etc. as required.(d) m.s fabricated, common base plate, coupling, couplingguard, foundation bolts etc. as required.(e)suitable cement concrete foundation duly plasteredand with anti vibration pads., 2280 lpm at 70 m head, (a) supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (jockey pump)(b)horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to is : 1520.(c) suitable hp squirell cage induction motor tefc type suitable for operation on 415 volts, 3 phase 50 hz ac supply with ip 55 class of protection for enclosure, horizontal foot mounted type with class-f insulation, conforming to is : 325.(d) m.s.fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required.(e) suitable cement concrete foundation duly plastered and with anti vibration pads., 180 lpm @70m head, fabrication, supply, insallation testing & commissioning of electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick crca sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, interconnection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per cpwd specification with following in coming and outgoings, suitable for operation on 415v, 3 phase, 50hz ac supply with enclosure protection class ip 42 as required :, incomings630a, 50ka 4 pole mccb, ics=100% icu rating digital voltmeter 0-500v with selector switch ammeter (0-630 a) with selector swtich & cts etc. led type ryb phase indicating lamps, on, off, trip indicating lamps set of copper bus bar 800amps outgoings (note : all outgoing feeders for pumps should have digital ammeter with selector switches, and led type on, off, trip indicating lamps)main fire pump200 amp, 50ka tpn mccb, ics=100% icu, with f
Tender For appointment of contractor/bidder for supply of material, erection, testing & commissioning for augmentation of 72 nos. existing 33 kv sub-stations (including civil work as per site requirements) on turnkey basis under revamped reforms-based and results-linked distribution scheme- 33/11 kv s/stn. items , 12.5 mva threee phase 50 hz, 33/11 kv step down outdoor onan power transformer complete with all accessories/fittings and conforming to latest nigam's technical specification with amendments relevant iss with latest amendments., , 33kv l & e switch (630amps), , 33kv isolators (630 amps), , 33 kv vcb, 36 kv, 1250a with 1000 mva (16 ka for 1 second) rupturing capacity vcb for out door use conforming to latest nigam's technical specification no. csc-24/r-ii/uh/dh/p&d/2020-21 with relevant iss & latest amendments thereof., , 33 kv c&r panel 24 v dc operated suitable for controlling one t/fs (with differential protection) as per nigam's tech. spec., relevant iss and latest amendments., , 33kv lightening arrestor sub-stn type 30kv 10ka with surge counter., , 33kv cts 600/300/5-5-5-5 with junction box, , 33kv pts with junction box, , 33kv post insulators, , disc fitting t&c type, , 11 kv vcb rating 1250 amp. 25 ka, 475 mva rupturing capacity 24v dc operated for incoming panel i/d type, , 11 kv vcb rating 400 amp. 25 ka, 475 mva rupturing capacity 24v dc operated for outgoing panel i/d type, , 11 kv vcb rating 400 amp. 25 ka, 475 mva rupturing capacity 24v dc operated for capacitor panel i/d type, , 11kv lightening arrestor sub-stn type 9 kv 10ka (heavy duty), , 11kv ncts 900/5a, , 11 kv automatically switched capacitor apfc capacitors panal 4.8 mvar complete (with l&e switch, structure and all allied material as per nigam's tech. spec., relevant iss and latest amendments, , structure for 33 kv cts (galvanized) wt. 87.62 kg., , structure for 33 kv pts (galvanized) wt. 87.62 kg., , structure for 33 kv la (galvanized) wt. 76.38 kg., , structure for 33 kv post insulators (galvanized) wt. 76.38 kg, , structure for 33 kv isolator (galvanized) wt.288.36 kg., , structure for l&e switch (galvanized) wt.288.36 kg., , structure for 11 kv nct (galvanized) wt.92.37 kg., , structure for cable stand, , gantry tower-2xdb-2, 2xdt-2, 2xdt-3 per sub-station, , structure for 11kv la/cable stand, , acsr conductor 80 sq mm(raccoon), , acsr conductor 0.2 sq in(panther), , 11kv single core xlpe cable 630mm², , 11 kv outdoor cable boxes for s/c 630 sq mm cable, , 11 kv indoor cable boxes for s/c 630 sq mm cable, , 11 kv xlpe cable 3 c x 300 sq. mm for capacitor bank, , 11 kv outdoor cable boxes for 3c x 300 sq mm cable, 11 kv indoor cable boxes for 3c x 300 sq mm cable, gi channel 100x50x6mm (gi) various size, gi angle iron 50 x 50 x 6 mm (gi) various size, gi flat 50 x 6 mm, gi flat 75 x 8 mm for earth mat in switchyard, earthing of s/stn. with pipe & earthing plate complete with machnary chamber, g.i pipe 40 mm dia 6 mtr. long for earthing set b class, premier synthetic insulating mat (class-b as per isi 15652:2006), pg clamps for panther conductor, gi nut & bolt off size, flood light led 240 watt (ip-67 rating), aluminium die cast body (make-, crompton, bajaj, phillips and havells only), 11 meters long pcc poles, un armoured copper control cable 2c x 6mm2, un armoured copper control cable 2c x 4mm2, un armoured copper control cable 7c x 2.5mm2, un armoured copper control cable 10c x 2.5mm2, un armoured copper control cable 3c x 4mm2, un armoured copper control cable 4c x 4mm2, un armoured copper control cable 6c x 4mm2, c-wedge connector for 0.2 sq. inch. panther conductor (nom. ai area, 200mm2), 33 kv polymeric disc insulators 70/90 kn b & s type, single tension fitting for 0.2 inch2 /150 mm2 acsr conductor, wooden cleat, ni-cd alkaline battery capacity (100ah) with static battery charger as, per nigam's specification., dry chemical type fire extinguisher (5 kgs), co2 type fire extinguisher (10 kgs), dry chemica
Tender For 1. work of “parking shed behind 500kv type ii staff quarter at hvdc premises padghe.”2.work of “renovation of toilet block at circle office at hvdc padghe.”3.work of “repair and renovation of 500kv hvdc tl (o&m) subdivision office premises and lines store room at hvdc padghe.”4.work of “fixing of paver block & extension of vehicle bay shed near 400kv control room at hvdc padghe.”5.work of “height rise of protection brickwall of 500kv store no. 1 at. hvdc premises padghe.”6.work of “painting of existing pipe line of fire hydrant system at +/-500kv hvdc terminal station padghe
Tender For corrigendum : emergent replacement, repairing rectification servicing work of existing entire defunct fireprotection system and fire detection system at bongaon ssh g plus 4 in the district of north 24 pgs under wbmscl during the year 25 26 2nd call
Tender For execution of external electrification work, installation of lightning protection device & fire fighting system at different projects in the state of odisha
Tender For annual rate contract (arc) for construction of foundations, cable trench, fireprotection wall, yard pcc / metal spreading & other ancillary civil works at various sub stations of vav am division under navsari circle for r&m work plan of fy 2026-27.