Tender For supply of supply, installation, testing and commissioning control panel 2 loops,sitc control panel 4 loops,sitc of network module the module shall connect panels,sitc of active repeater panel to be integrated with fire alarm,sitc of addressable ip67 rated multi- heat sensor,sitc of analogue addressable photo thermal smoke detector,sitc of analogue addressable photo thermal smoke detector,sitcof addressable multi sensor with co detection,sitcc of response indicator on surface or recessed,sitc of short circuit isolator module base with all mounting,sitc of analogue addressable dual action,sitc of addressable horn with a maximum output of up to 100 db a,sitc of analogue addressable supervised monitor module,sitc of analogue addressable supervised control module,supplying and laying through walls,complete earthing electrode and excavation etc,earth continuity conductor,false ceiling board and cross tee,butterfly valves (v2) as per is 13095,butterfly valves (v2) as per is 13095
Tender For supply of supply, installation, testing and commissioning control panel 2 loops,sitc control panel 4 loops,sitc of network module the module shall connect panels,sitc of active repeater panel to be integrated with fire alarm,sitc of addressable ip67 rated multi- heat sensor,sitc of analogue addressable photo thermal smoke detector,sitc of analogue addressable photo thermal smoke detector,sitcof addressable multi sensor with co detection,sitcc of response indicator on surface or recessed,sitc of short circuit isolator module base with all mounting,sitc of analogue addressable dual action,sitc of addressable horn with a maximum output of up to 100 db a,sitc of analogue addressable supervised monitor module,sitc of analogue addressable supervised control module,supplying and laying through walls,complete earthing electrode and excavation etc,earth continuity conductor,false ceiling board and cross tee,butterfly valves (v2) as per is 13095,butterfly valves (v2) as per is 13095
Tender For corrigendum : supply of loop card for fire alarm control panel , monitor module addressable type monitor module. , control relay module addressable control relay module. , optical cum thermal detector intelligent addressable multi criteria optical cum thermal detector wit , optical cum chemical detector intelligent addressable type, maintenance easy optical cum chemical de , response indicator , break glass type manual call point intelligent addressable break glass type manual call point. , sounder or hooter addressable type loop powered /external powered sounder or hooter with multiple to
Tender For corrigendum : repair and comprehensive maintenance of swimming pool plant and equipments fire fighting system at af stn nal under ge (af) nal - comprehensive annual maintenance of swimming pool comprises of the following equipments complete all as specified and directed.(a) pumping sets of capacity 3.5 hp - 05 nos (01 as standby) (b) pressure filter of filtering capacity 50 cum/hr - 04 nos (01 as standby)(c) dosing pump - 02 nos (one for chlorination and one for soda ash)(d) electrical panel board consisting of starters of suitable rating complete.note: rate quoted by the contractor shall deemed to be included for the following :-(i) contractor shall provide trained technician and a helper, who will visit swimming pool once in a week, to check and servicing of the equipments above to ensure the serviceability and proper functioning of swimming pool.(ii) grease and lubricating oil shall be provided by the contractor at his own end and nothing extra shall be payable on this account. (iii) cleaning all swimming pool building inside, plant room, equipments including surrounding area of the buildings. (iv) check serviceability of all self priming recirculation pump of single stage / horizontal self priming pump set of 3.5hp / 3.26 kw capacity and all other connected items., comprehensive annual maintenance of fire fighting system in sekhon hall , new tech flight, sre and new atc of the following equipments complete all as specified and directed.(a) main fire pump with centrifugal motor of existing capacity- 04 nos (b) jockey fire pump with electric motor of existing capacity - 04 nos (c) makeup fire pump- 04 nos(d) dg fire pump with engine - 04 nos note: rate quoted by the contractor shall deemed to be included for the following :-(i) contractor shall provide trained technician and a helper, who will visit fire fighting installation in sekhon hall , new tech flight and new atc once in a week, to check and servicing of the equipments above to ensure the serviceability and proper functioning of installation.(ii) grease and lubricating oil shall be provided by the contractor at his own end and nothing extra shall be payable on this account.(iii) cleaning all fire fighting installation buildings (sekhon hall , new tech flight and new atc) inside, plant room,equipments including surrounding area of the building. (iv) check serviceability of all self priming recirculation pump of single stage / horizontal self priming pump set of all existing capacity and all other connected items., s&f in repair pressure pump limit switch of capacity 1psi to 4 psi and 230 volt as per existing make and model fixed on pressure booster line complete all as specified and directed., supply, installation, testing and commissioning in repair of detectors complying with and type certified to en-45 addressable type multi sensor detector with heat and smoke combination with base with self built intelligence as per is:11360 (for annexes) complete all as specified and directed., supply, installation, testing and commissioning in repair of addressable manual call point / pill station resettable type with base complete all as specified and directed, supply, installation, testing and commissioning in repair of fire alarm sounder/siren electronic type horizontal single stage continuous type normal operation for atleast 50 minutes with sound level 65 db to 120 db measured at 1.5 mtr with sound output variation +5 db 500 mtr complete all as specified and directed, supply and fixing in repair addressable monitor module for activating the sirens complete all as specified and directed, taking out old unserviceable hose box by cutting and welding and s&f hose box made of 18 gauge ms sheet 800mmx 600 mm x 250 mm with double door with 4 mm thick glasses and door frame made of 16 gauge ms sheet for keeping 2 nos hose pipe of length 15 mtr each branch pipe nozzle coupling etc and painted fire red out side and brilliant white inside yard complete all as specified and dire
Tender For bid to ras supply of compact crash fire tender : : - chassis tata 407 gold sd or sfc 407 or tata yodha 4x4 or other bs 6 complaint chassis of equivalent or superior , water tank , foam system , fire pump , roof monitor , hose reel delivery hoses and outlet , dcp system , scba and personal protective equipment , lighting and electrical , body work compartment and livery , training and commissioning
Tender For bid to ras bid to ras supply of storage 300 tb , meta data storage san storage msa 2060 , fc switch , usb powered external hard disk drives 4 tb ssd , cables and accessories , server , fault tolerance server , smart 42 u rack with access control and 15kw cooling redundant fire suppression system camera rodent repellent system to house servers and switches , 10 g switches and routers , layer 3 switch , 10 g firewall , firewall , workstation with dual monitor , miscellaneous items installation and commissioning charges , resident engineer cost per year , windows server license latest , ms sql server , nas 500tb , management device , color ink tank printer , printer mfd a3 , color laser printer a4