Tender For supply of supply, installation, testing and commissioning of microprocessor based intelligent addressable main firealarmcontrolpanel with 2 loops modules , supply, installation, testing and commissioning of intelligent addressable multi criteria detector with a combination of optical and thermal including mounting base , supply, installation, testing and commissioning of intelligent addressable smoke detector including mounting base with led , supply, installation, testing and commissioning of addressable weather proof outdoor manual call point with ip rating of ip 67 , supply, installation, testing and commissioning of addressable loop powered stand alone sounder outdoor with inbuilt isolators , supply, installation, testing and commissioning of active repeater panel to be connected peer to peer with main firealarmpanel
Tender For supply and installation of antistatic raised access flooring (false flooring) for instrumentation controlpanel and i/o rack rooms in tm#5 area at tnpl unit ii
Tender For corrigendum : supply of intelligent multi-criteria detectors for upgradation of fire protection system , manual call point for upgradation of fire protection system , zone monitoring unit for upgradation of fire protection system , monitor module for upgradation of fire protection system , relay module for upgradation of fire protection system , loop powered remote hooters for upgradation of fire protection system , repeat response indicator for upgradation of fire protection system , fas controlpanel having 8 loop capacity with redundant cpu , zone indicating panel for upgradation of fire protection system , firealarmcontrolpanel having 2 loop capacity with single controller , lcps -bare cabinets for upgradation of fire protection system , standalone ac to dc psu-smps for lcps for upgradation of fire protection system , hand- switches, push buttons, indicating lamps for upgradation of fire protection system , loop powered-cpu motherboard- backplane- bus powered relay modules with at least 8 change over contacts for upgradation of fire protection system , spares for fas controlpanel min. one type of each card or 10 percentage whichever is more standalone psu etc. , spares for relays other loose components and modules. for upgradation of fire protection system , test meter for smoke detectors , smoke detector removal tool kit with 6 m collapsible-concentric rod , smoke detector testing tool kit , aerosol gas cans 250 ml , heat detector tester , 1 pair 1.5sq. mm overall shielded hrpvc insulated frls pvc sheathed un-armoured cable for upgradation of fire protection system , 5 pair individually shielded 1.5sq.mm hrpvc insulated frls pvc sheathed unarmoured cables for upgradation of fire protection system , 10 pair individually shielded 1.5sq.mm hrpvc insulated frls pvc sheathed unarmoured cables for upgradation of fire protection system , 19 mm flexible gi conduit for upgradation of fire protection system , supply of 25 mm rigid hot dipped gi conduit including accessories , supply of nickel plated double compression brass cable glands , other accessories mcbs sealing compound etc , installation and commissioning of the system for upgradation of fire protection system