Tender For repair/maintenance of diesel generator set with central panel and other connected items at zone 5 and 1(a,b,c) zone 1, 3 (a and b), zone 2 and zone 4 under ge (s) tezpur - maint and servicing of dg set 320-400 kva conopy type with amf panel (if installed ), through authorise service agency of oem , including replacment of defective/wornout parts with new spares such as filters, gaskets, v belts, engine oil, coolant for radiator rubber hoses with clamps, nuts bolts and cleaning of alternator with vaccum cleaner , including greasing of bearings of engine and alternator, tappet setting, checking of batteries, adding distilled water and cleaning of pol tank and radiator etc complete all as specified and directed.note:- 1. spares required for above maint will be measured and paid separately under relevent items of schedule. 2. all breakdown calls should be attended., all as per item no-1 above but for dg set of capacity 180-250 kva complete all as specified and directed, all as per item no-1 above but for dg set of capacity 125-160 kva complete all as specified and directed, all as per item no-1 above but for dg set of capacity 40-100 kva complete all as specified and directed, all as per item no-1 above but for dg set of capacity 10-35 kva complete all as specified and directed, supply only fuel filter for 300-400 kva dg set, complete all as specified and directed, supply only fuel filter for 125-250 kva dg set,complete all as specified and directed complete all as specified and directed, supply only fuel filter for 10-100 kva dg set,complete all as specified and directed, supply only lub oil filter for 300-400 kva dg set,complete all as specified and directed, supply only lub oil filter for 125-250 kva dg set,complete all as specified and directed, supply only lub oil filter for 10-100 kva dg set,complete all as specified and directed, supply only air cleaner filter ( inner and outer ) for 300-400 kva dg set, complete all as specified and directed, supply only air cleaner filter (inner and outer ) for 125-250 kva dg set,complete all as specified and directed, supply only air cleaner filter (inner and outer ) for 10-100 kva dg set,complete all as specified and directed, supply only bypass filter for 300-400 kva dg set, complete all as specified and directed, supply only bypass filter for 125-250 kva dg set,complete all as specified and directed, supply only bypass filter for 10-100 kva dg set,complete all as specified and directed, supply only v belt for 300-400 kva dg set, complete all as specified and directed, supply only v belt for 125-250 kva dg set, complete all as specified and directed, supply only v belt for 10-100 kva dg set, complete all as specified and directed, supply only coolant for radiators complete all as specified and directed., supply only engine oil multi grade 15w40 complete all as specified and directed., s & f in repair display controlpanel ( base card) for 10 to 100 kva dg set complete all as specified and directed ., s & f in repair display controlpanel (base card) for 125 to 250 kva dg set complete all as specified and directed., s & f in repair display controlpanel (base card) for 300 to 400 kva dg set complete all as specified and directed., s & f in repair fuel actuator with o ring for 300 to 400 kva dg set complete all as specified and directed., s & f in repair key switch for 10 to 400kva dg set complete all as specified and directed., s & f in repair coolant temperature sensor (coolent control safety) for 10 to 400kva dg set complete all as specified and directed., s & f in repair amf controller assy for auto/manual operation for 10 to 100 kva dg set complete all as specified and directed., s & f in repair amf controller assy for auto/manual operation for 125 to 250 kva dg set complete all as specified and directed., s & f in repair amf controller assy for auto/manual operation for 300 to 400kva dg set complete all as specified and directed., s & f in rep
Tender For supply of detector removal tool as per atc , loop card micro module as per atc , serial esser net interface modules as per atc , network card essernet series 2 nw card 64 k as per atc , main firealarmcontrolpanels cpu card for facp as per atc , iq8 repeater panel as per atc , heat detector as per atc , otg multisensor fire detector co iq8quad with isolator as per atc , o2t multisensor fire detector iq8quad with isolator as per atc , otblue multisensor fire detector iq8quad with isolator as per atc , optical smoke detector iq8quad with isolator as per atc , controller for lhdc as per atc , esserbus transponder rzt 24 v as per atc , flame detectors as per atc , usb cable ab and serial connecting cable as per atc
Tender For spares for fas detector removal tool as per atc, loop card micro module as per atc, serial esser net interface modules as per atc, network card essernet series 2 nw card 64 k as per atc, main firealarmcontrolpanels cpu card for facp as per atc, iq8 repeater panel as per atc , heat detector as per atc, otg multisensor fire detector co iq8quad with isolator as per atc, o2t multisensor fire detector iq8quad with isolator as per atc, otblue multisensor fire detector iq8quad with isolator as per atc, optical smoke detector iq8quad with isolator as per atc, controller for lhdc as per atc, esserbus transponder rzt 24 v as per atc, flame detectors as per atc, usb cable ab and serial connecting cable as per atc
Tender For corrigendum : supply of loop card for firealarmcontrolpanel , monitor module addressable type monitor module. , control relay module addressable control relay module. , optical cum thermal detector intelligent addressable multi criteria optical cum thermal detector wit , optical cum chemical detector intelligent addressable type, maintenance easy optical cum chemical de , response indicator , break glass type manual call point intelligent addressable break glass type manual call point. , sounder or hooter addressable type loop powered /external powered sounder or hooter with multiple to
Tender For supply of plasticized pvc tapes with non-thermosetting adhesive for electrical purpose (v2) isi marked to is 7809 (part 3/ sec1) (q2) , xlpe cable for working voltage up to and including 1.1 kv marked to is 7098 (part 1) (q2) , canvas fire hose with male and female coupling 63mm dia x 15 mtr long , ms fire hook with babu standard length , ms fire double hose box of size 800x600x250mm , ms fire hose reel drums 3 or 4 inch for 30 mtr hose , ms fire hose reel drums 1 inch for 30 mtr hose , ms fire hose reel heavy duty 20mm dia x 30 mtr long for hose , fire hydrant landing valves gun metal single outlet 63 x80 mm dia flanged pipes , fire hydrant landing valves gun metal double outlet 63x80 mm dia flanged pipes , non return valve 150 mm dia pn 1.6 , non return valve 100 mm dia pn 1.6 , butterfly valve 150 mm dia , butterfly valve 100 mm dia , foot valve 150 mm dia , foot valve 100 mm dia , firealarmcontrolpanel conventional type 8 zone , firealarmcontrolpanel conventional type 12 zone , firealarmcontrolpanel addressable type up to 99 loop , manual call point , electronic hooter , heat detector automatic reset type , pvc insulation tapes size width 20 mm length 10 mtr , hydrant key as per isi * /bid number : gem/2026/b/7704220 + /dated: 24-06-2026 ' ' / bid document 1 / 25
Tender For tender for supply of supplying , installing , testing and commissioning approved make microprocessor based single (01) loop , networkable addressable firealarmcontrolpanel , supplying , installing , testing and commissioning approved make digital audio amplifier. , supplying , installing , testing and commissioning approved make remote paging station for zone selection , supplying , installing , testing and commissioning approved make modbus interface gateway , the mimic annunciator for the firealarmcontrolpanels (facp). , supplying , installing , testing and commissioning approved make addressable multi-criteria photo-thermal detector , supply , installation , testing and commissioning addressable self-test multi-criteria photo-thermal detector , supplying , installing , testing and commissioning approved make addressable manual call point , supplying , installing , testing and commissioning approved make addressable control module for sounders , supplying , installing , testing and commissioning approved make addressable relay module for ahu , access control , lifts , staircase pressurization , fire suppression & other third party outputs , supplying , installing , testing and commissioning approved make isolator module for isolating short / dewired / loose circuits with automatic resetting arrangement , supplying , installing , testing and commissioning approved make response indicator , supplying , installing , testing and commissioning of hooter cum strobe with in-built lithiumion battery , supplying , installing , testing and commissioning approved make 2w multi-tap wall mount speakers , supplying , installing , testing and commissioning of approved make auto dialer which supports gsm and pstn both , supply and laying of 2 c x 1.5 sq.mm. armoured cu multi-stranded twisted shielded frls copper cable , red in colour. , camc for 4 years after expiry of one year warranty of addressable fire detection system
Tender For tender for supply of sitc and maintenance of addressable firealarm and detection system at uco bank - supplying , installing , testing and commissioning approved make microprocessor based multi-loop , networkable addressable 02 loop firealarmcontrolpanel with minimum 10 inch 1024x600 resolution lcd with touch capability , including audible and visible feedback , backlit by a long life , solid-state lcd. it shall also include a full qwerty-style keypad on the color , touchscreen display. the display shall have the ability to scroll events by type (i.e. firealarm , supervisory alarm , trouble , etc) using the touchscreen with customizable buttons , 10000 history events & autolearn feature for programming. the system can be supported upto 2000 generation zone & 2000 logic zone & 50 releasing zone. the panels in network having true peer to peer provision. the panel shall have provision to support up to 50 releasing zones to protect against 50 independent hazards.the panel should be equipped with sufficient numbers of loops considering 20% spare capacity in each loop and shall be extendable upto 10 loops. , supplying , installing , testing and commissioning approved make modbus interface gateway for communication with bms / other utilities. modbus shall support supports reads of up to 100 registers at a time. modbus gateway shall act as an independent node communicating on the peer to peer network and shall not be dependent on the firepanel cpu for operation. modbus over tcp/ip , meets ul 864 , 10th edition requirements , supports two modbus masters & monitored 10 cpu nodes . failure of firepanel cpu shall not result in failure of modbus gateway. the gateway card shall be ul listed , the mimic annunciator for the firealarmcontrolpanels (facp). this provides the facp with remote , serially-connected display. a five inch touchscreen display provides system status , point information , and event counters. the display shows two events simultaneously , and pages through up to 50 of the highest priority events in the system. the remote display also provides system control with six programmable softtouch buttons as well as acknowledge , silence , reset and drill. , supplying , installing , testing and commissioning approved make addressable multi-criteria photo-thermal detector with sensitivity range of 0.5 to 4.0% obs/ft.the intelligent multi criteria detection device shall include the ability to combine the signal of the thermal sensor with the signal of the photoelectric signal in an effort to react hastily in the event of a fire situation. it shall also include the inherent ability to distinguish between a fire condition and a false alarm condition by examining the characteristics of the thermal and smoke sensing chambers and comparing them to a database of actual fire and deceptive phenomena. the detector shall have twin bi-colour led for 360 deg viewing. addressing shall be with user friendly rotary decimal switches. detectors having base addressing must provide protective cap. detectors with soft addressing must provide programming tool. the detector sensitivity (day & night) shall be controlled from the panel to get accustomed to the local environment. the detector shall be ul listed & fm approved. , supply , installation , testing and commissioning addressable self-test multi-criteria photo-thermal detector with sensitivity range of 0.5 %/ft to 4.0 %/ft obs. intelligent multi criteria detection device shall include the ability to combine signal of the thermal sensor with photoelectric signal in an effort to react hastily in the event of a fire situation. , supplying , installing , testing and commissioning approved make addressable manual call point ( break glass type). the device shall have an led which shall blink in normal state & get steady on activation to monitor the heath status of the device. the device shall be ul listed & fm approved. , supplying , installing , testing and commi