Web Analytics Made Easy - StatCounter

Flow Monitor Tenders

Get complete information related to latest Flow Monitor Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Flow Monitor Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Flow Monitor Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government And Public Sector

CTN :45562164 Due date: 29 Jun, 202629 Jun, 2026 9.98 Lacs
Tender For renovation of site office building proposed for e flow monitoring site at tajewala downstream of hatnikund barrage under ysd, uyd, new delhi.

Central Government/Public Sector

CTN :44814206 Due date: 15 Jun, 202615 Jun, 2026 NA
Tender For corrigendum : procurement of lub oil flow monitors for ntpc mouda

corporations/Associations/Others

CTN :45468496 Due date: 22 Jun, 202622 Jun, 2026 22.01 Lacs
Tender For supply of transducer dc volt 0 to 600v , transducer dc 0 to 600 , dc voltage transducer input range , dc voltage transducer 0 to 75mv , dc voltage transducer 0 to 100mv d , dc voltage transducer 0 to 100mv , cubical fan 6pole , air flow monitoring unit with sensor , metrosil 5a c 620 , metrosil, 1a , oil pump assembly

CTN :45398833 Due date: 09 Jun, 202609 Jun, 2026 NA
Tender For supply of id fan lci panel air flow monitor as per boq-tds - procurement of id fan lci panel air flow monitor as per boq-tds

CTN :45430175 Due date: 24 Jun, 202624 Jun, 2026 1.00 Crore
Tender For purchase of icp-oes inductively coupled plasma optical emission spectrometer, other items accessories for the soil testing laboratory shimla o/o senior analytical chemist, h.p. shimla-04 and stl palampur, o/o dda kangra, h.p. for the analysis of soil - icp oes system, microwave digester, ultra-pure water purification system, ups 10kva, signature :name & designation :date :name & address of the firm :note:(a) price/rate should be quoted for all the items as per above annexure vii.(b) the bids would be evaluated for all items together.(c) the evaluation shall be based on the total price of goods and related services at project site including gst and any other taxes.(d) rates for amc/cmc after the warranty period upto five years may also be quoted with gst, however, this will not be a part of price bid for l1.(e) rates will be quoted in .xls boq file and bifurcation of price bid .pdf file in financial packet only.

corporations/Associations/Others

CTN :45236511 Due date: 10 Jun, 202610 Jun, 2026 NA
Tender For corrigendum : supply, installing, testing and commissioning of iot based smart flow monitoring system and drainage pump monitoring system including associated works including 5 years of o&m for porbandar municipal corporation

CTN :45346428 Due date: 15 Jun, 202615 Jun, 2026 NA
Tender For purchase of renewable energy practical equipments - equipments for renewable energy practices:, rc phase shift oscillator oscillator type: rc phase shift oscillator using transistor / op-amp configuration. input supply: 230 v / 50 hz ac with regulated internal dc supply. output frequency range: 100 hz 10 khz adjustable. output: sinusoidal waveform with adjustable amplitude up to 10 vpp. rc network: three-stage rc phase shift network with frequency control arrangement. cro test points: dedicated cro terminals at amplifier output, each rc stage, and final output for waveform and phase-shift observation. protection: over-voltage and short-circuit protection provided. indicators and controls: power on led indication with frequency and gain adjustment controls. accessories: patch cords, circuit diagram, strain guage characteristics kitac mains power supply: 230 v 10%, 50 hz metal foil strain gauge mounted on beam/cantilever. strain measurement under applied load. wheatstone bridge arrangement. signal conditioning and amplification circuit. instrumentation amplifiers with 3 digit display for strain / output voltage. zero and gain adjustment controls. provision for applying calibrated loads. table-top trainer with labelled panel. test points for signal measurement. built-in dc power supplies and wooden closed cabinet. supplied with patch cords, load cell characteristics kit input supply: 230 v / 50 hz ac with regulated internal dc supply. sensor: strain gauge load cell with suitable mounting arrangement. load range: 0 10 kg. display: digital display for load/output indication. cro / test points: test points provided for observing bridge output, amplifier output, and signal conditioning stages. controls: zero adjustment and calibration controls provided. protection: overload and short-circuit protection provided. accessories: loading arrangement, connecting leads., measurement of tank level using rotometer input supply: 230 v / 50 hz ac with regulated internal dc supply. tank arrangement: transparent tank with 30 liters capacity with suitable supporting stand. rotameter range: 0 4000 l/hr calibrated rotameter. flow system: pump, control valves, and piping arrangement provided for continuous flow operation. measurement facility: provision for flow-based tank level measurement and observation. display / observation: calibrated level indication with flow monitoring arrangement. test points: output terminals provided for monitoring sensor/output signals. accessories: connecting tubes., measurement of tank level using displacer type level transmitter input supply: 230 v / 50 hz ac with regulated internal dc supply unit. measurement principle: buoyancy (archimedes principle) using displacer element. tank arrangement: transparent experimental tank with 30 liters capacity and suitable mounting stand. level range: suitable laboratory-scale level measurement (0 100% tank height). sensor system: displacer type level transmitter with continuous level output signal. display unit: digital indicator for level display in percentage / engineering units. output signals: standard analog output (4 20) ma / (0 10) v provided for monitoring. test points: provided for transmitter output, signal conditioning, and display unit verification. controls: zero and span calibration adjustment provided for setting level reference. protection: over-voltage and short-circuit protection for electronic modules. accessories: connecting cables, piping arrangement, loading medium (water), measurement of temperature using pt100 input supply: 230 v / 50 hz ac with regulated internal dc power supply unit. sensor: pt100 resistance temperature detector (rtd) probe with stainless steel sheath. measurement principle: resistance variation of platinum element with temperature. temperature range: 0 c to 150 c (or suitable laboratory range). display unit: digital temperature indicator with direct c display. accuracy: high accuracy with linearized rtd signal conditioning circuit. sign

CTN :45346446 Due date: 11 Jun, 202611 Jun, 2026 NA
Tender For purchase of lab equipments for res dept - purchase of lab equipments for res dept, rc phase shift oscillator (iemcode:o001)specifications: oscillator type: rc phase shift oscillator using transistor / op-amp configuration. input supply: 230 v / 50 hz ac with regulated internal dc supply. output frequency range: 100 hz 10 khz adjustable. output: sinusoidal waveform with adjustable amplitude up to 10 vpp. rc network: three-stage rc phase shift network with frequency control arrangement. cro test points: dedicated cro terminals at amplifier output, each rc stage, and final output for waveform and phase-shift observation. protection: over-voltage and short-circuit protection provided. indicators and controls: power on led indication with frequency and gain adjustment controls. accessories: patch cords, circuit diagram., strain guage characteristi cs kit(iemcode:o002)specifications: ac mains power supply: 230 v 10%, 50 hz metal foil strain gauge mounted on beam/cantilever. strain measurement under applied load. wheatstone bridge arrangement. signal conditioning and amplification circuit. instrumentation amplifiers with 3 digit display for strain / output voltage. zero and gain adjustment controls. provision for applying calibrated loads. no rs.10,000 2 table-top trainer with labelled panel. test points for signal measurement. built-in dc power supplies and wooden closed cabinet. supplied with patch cords, load cell characteristi cs kit(item code: o003)specifications:input supply: 230 v / 50 hz ac with regulated internal dc supply. sensor: strain gauge load cell with suitable mounting arrangement. load range: 0 10 kg. display: digital display for load/output indication. cro / test points: test points provided for observing bridge output, amplifier output, and signal conditioning stages. controls: zero adjustment and calibration controls provided. protection: overload and short-circuit protection provided. accessories: loading arrangement, connecting leads., measurement of tank level using rotometer(item code: o004)specifications: input supply: 230 v / 50 hz ac withregulated internal dc supply. tank arrangement: transparent tank with 30 liters capacity with suitable supporting stand. rotameter range: 0 4000 l/hr calibrated rotameter. flow system: pump, control valves, and piping arrangement provided for continuous flow operation measurement facility: provision for flow-based tank level measurement and observation. display / observation: calibrated level indication with flow monitoring arrangement. test points: output terminals provided for monitoring sensor/output signals. accessories: connecting tubes., measurement of tank level using displacer type level transmitter(item code: o005)specifications: input supply: 230 v / 50 hz acwith regulated internal dcsupply unit. measurement principle:buoyancy(archimedesprinciple) using displacerelement tank arrangement: transparent experimental tank with 30 liters capacity and suitable mounting stand. level range: suitable laboratory-scale level measurement (0 100% tank height). sensor system: displacer type level transmitter with continuous level output signal. display unit: digital indicator for level display in percentage / engineering units. output signals: standard analog output (4 20) ma / (0 10) v provided for monitoring. test points: provided for transmitter output, signal conditioning, and display unit verification. controls: zero and span calibration adjustment provided for setting level reference. protection: over-voltage and short-circuit protection for electronic modules. accessories: connecting cables, piping arrangement, loading medium (water), measurement oftemperature using pt100(item code: o006a)specifications: input supply: 230 v / 50 hz ac with regulated internal dc power supply unit. sensor: pt100 resistance temperature detector (rtd) probe with stainless steel sheath measurement principle: resistance variation of platinum element with temperature. temperature range: 0 c to

corporations/Associations/Others

CTN :45151981 Due date: 26 May, 202626 May, 2026 39.76 Lacs
Tender For m and r to talegaon chakan centralized wss replacement of electromagnetic flowmeter with wireless flow monitoring system on raw water raising main at raw water pumping station talegaon

CTN :45238482 Due date: 08 Jun, 202608 Jun, 2026 NA
Tender For providing of custom bid for services - installation of aas & microwave digester through gem portal.
 Loading, Please wait...

Connect us via What's Up