Get complete information related to latest Flow Monitor Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Flow Monitor Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Flow Monitor Tenders.
Tender For renovation of site office building proposed for e flowmonitoring site at tajewala downstream of hatnikund barrage under ysd, uyd, new delhi.
Tender For supply of transducer dc volt 0 to 600v , transducer dc 0 to 600 , dc voltage transducer input range , dc voltage transducer 0 to 75mv , dc voltage transducer 0 to 100mv d , dc voltage transducer 0 to 100mv , cubical fan 6pole , air flowmonitoring unit with sensor , metrosil 5a c 620 , metrosil, 1a , oil pump assembly
Tender For tender for supply of slide test for pregnancy agglutination inhibition test kit , rapid test for scrub typhus tsutsugamushi antibody igm ivd , rapid hcv card test , liquor formaldehyde 40 percent w by v , cell pack dfl for xnl 550 , cell pack dcl for xnl 550 , lysercell wdf for xnl 550 , calibrator for xnl 550 , check for xnl 550 , rapid visual test for detection of dengue ns1 ag and differential detection of igm and igg antibodies human serum or plasma kit of 10 test , spot test kit for typhoid igg or igm , system pack uric acid for em360 , system pack triglyceride for em360 , system pack direct bilirubin for em360 , system pack total bilirubin for em360 , system pack sgot for em360 , system pack sgpt for em360 , system pack lipase , system pack ggt , system pack ckmb , hba1c kit for em360 , system pack hdl direct for em360 , system pack alkaline phosphate , chikunguniya test kit of 10 , sample cup cuvette for em 360 of 2 ml 500 in each pack , rapid test card for syphillis pack of 50 tests , multistisc9sg for urine analyser , distilled water , system pack ldl direct for em360 , sterile urine sample container , crp latex rapid test rhelax of 35 tests , hepatitis b surface antigen hbsag rapid test kit , elisa test for detection of hiv 1 and 2 antibody and p24 antigen 4th generation elisa 96 tests , elisa test for detection of hbsag antigen upto 0 point 05 ng per ml of 96 tests , hcv elisa kit advanced 3rd generation of 96 tests , 4th generation hiv rapid test , abo forward grouping with rh grouping and direct antiglobulin test dat test by column agglutination technology for newborn frouping box of 24 cards , anti human globulin igg card column agglutination technology box of 24 cards , serum anti d igg plus igm for saline tube test , serum haemagglutinating group a anti b monoclonal , serum haemagglutinating group b anti a monoclonal , serum haemagglutinating group c anti ab monoclonal , serum anti a 1 of 5 ml , serum anti h of 5 ml , abo rh forward and reverse grouping card by column agglutination technology cat box of 24 cards , id diluent 2 bottle of 250 ml liss
Tender For corrigendum : supply, installing, testing and commissioning of iot based smart flowmonitoring system and drainage pump monitoring system including associated works including 5 years of o&m for porbandar municipal corporation
Tender For purchase of renewable energy practical equipments - equipments for renewable energy practices:, rc phase shift oscillator oscillator type: rc phase shift oscillator using transistor / op-amp configuration. input supply: 230 v / 50 hz ac with regulated internal dc supply. output frequency range: 100 hz 10 khz adjustable. output: sinusoidal waveform with adjustable amplitude up to 10 vpp. rc network: three-stage rc phase shift network with frequency control arrangement. cro test points: dedicated cro terminals at amplifier output, each rc stage, and final output for waveform and phase-shift observation. protection: over-voltage and short-circuit protection provided. indicators and controls: power on led indication with frequency and gain adjustment controls. accessories: patch cords, circuit diagram, strain guage characteristics kitac mains power supply: 230 v 10%, 50 hz metal foil strain gauge mounted on beam/cantilever. strain measurement under applied load. wheatstone bridge arrangement. signal conditioning and amplification circuit. instrumentation amplifiers with 3 digit display for strain / output voltage. zero and gain adjustment controls. provision for applying calibrated loads. table-top trainer with labelled panel. test points for signal measurement. built-in dc power supplies and wooden closed cabinet. supplied with patch cords, load cell characteristics kit input supply: 230 v / 50 hz ac with regulated internal dc supply. sensor: strain gauge load cell with suitable mounting arrangement. load range: 0 10 kg. display: digital display for load/output indication. cro / test points: test points provided for observing bridge output, amplifier output, and signal conditioning stages. controls: zero adjustment and calibration controls provided. protection: overload and short-circuit protection provided. accessories: loading arrangement, connecting leads., measurement of tank level using rotometer input supply: 230 v / 50 hz ac with regulated internal dc supply. tank arrangement: transparent tank with 30 liters capacity with suitable supporting stand. rotameter range: 0 4000 l/hr calibrated rotameter. flow system: pump, control valves, and piping arrangement provided for continuous flow operation. measurement facility: provision for flow-based tank level measurement and observation. display / observation: calibrated level indication with flowmonitoring arrangement. test points: output terminals provided for monitoring sensor/output signals. accessories: connecting tubes., measurement of tank level using displacer type level transmitter input supply: 230 v / 50 hz ac with regulated internal dc supply unit. measurement principle: buoyancy (archimedes principle) using displacer element. tank arrangement: transparent experimental tank with 30 liters capacity and suitable mounting stand. level range: suitable laboratory-scale level measurement (0 100% tank height). sensor system: displacer type level transmitter with continuous level output signal. display unit: digital indicator for level display in percentage / engineering units. output signals: standard analog output (4 20) ma / (0 10) v provided for monitoring. test points: provided for transmitter output, signal conditioning, and display unit verification. controls: zero and span calibration adjustment provided for setting level reference. protection: over-voltage and short-circuit protection for electronic modules. accessories: connecting cables, piping arrangement, loading medium (water), measurement of temperature using pt100 input supply: 230 v / 50 hz ac with regulated internal dc power supply unit. sensor: pt100 resistance temperature detector (rtd) probe with stainless steel sheath. measurement principle: resistance variation of platinum element with temperature. temperature range: 0 c to 150 c (or suitable laboratory range). display unit: digital temperature indicator with direct c display. accuracy: high accuracy with linearized rtd signal conditioning circuit. sign
Tender For purchase of lab equipments for res dept - purchase of lab equipments for res dept, rc phase shift oscillator (iemcode:o001)specifications: oscillator type: rc phase shift oscillator using transistor / op-amp configuration. input supply: 230 v / 50 hz ac with regulated internal dc supply. output frequency range: 100 hz 10 khz adjustable. output: sinusoidal waveform with adjustable amplitude up to 10 vpp. rc network: three-stage rc phase shift network with frequency control arrangement. cro test points: dedicated cro terminals at amplifier output, each rc stage, and final output for waveform and phase-shift observation. protection: over-voltage and short-circuit protection provided. indicators and controls: power on led indication with frequency and gain adjustment controls. accessories: patch cords, circuit diagram., strain guage characteristi cs kit(iemcode:o002)specifications: ac mains power supply: 230 v 10%, 50 hz metal foil strain gauge mounted on beam/cantilever. strain measurement under applied load. wheatstone bridge arrangement. signal conditioning and amplification circuit. instrumentation amplifiers with 3 digit display for strain / output voltage. zero and gain adjustment controls. provision for applying calibrated loads. no rs.10,000 2 table-top trainer with labelled panel. test points for signal measurement. built-in dc power supplies and wooden closed cabinet. supplied with patch cords, load cell characteristi cs kit(item code: o003)specifications:input supply: 230 v / 50 hz ac with regulated internal dc supply. sensor: strain gauge load cell with suitable mounting arrangement. load range: 0 10 kg. display: digital display for load/output indication. cro / test points: test points provided for observing bridge output, amplifier output, and signal conditioning stages. controls: zero adjustment and calibration controls provided. protection: overload and short-circuit protection provided. accessories: loading arrangement, connecting leads., measurement of tank level using rotometer(item code: o004)specifications: input supply: 230 v / 50 hz ac withregulated internal dc supply. tank arrangement: transparent tank with 30 liters capacity with suitable supporting stand. rotameter range: 0 4000 l/hr calibrated rotameter. flow system: pump, control valves, and piping arrangement provided for continuous flow operation measurement facility: provision for flow-based tank level measurement and observation. display / observation: calibrated level indication with flowmonitoring arrangement. test points: output terminals provided for monitoring sensor/output signals. accessories: connecting tubes., measurement of tank level using displacer type level transmitter(item code: o005)specifications: input supply: 230 v / 50 hz acwith regulated internal dcsupply unit. measurement principle:buoyancy(archimedesprinciple) using displacerelement tank arrangement: transparent experimental tank with 30 liters capacity and suitable mounting stand. level range: suitable laboratory-scale level measurement (0 100% tank height). sensor system: displacer type level transmitter with continuous level output signal. display unit: digital indicator for level display in percentage / engineering units. output signals: standard analog output (4 20) ma / (0 10) v provided for monitoring. test points: provided for transmitter output, signal conditioning, and display unit verification. controls: zero and span calibration adjustment provided for setting level reference. protection: over-voltage and short-circuit protection for electronic modules. accessories: connecting cables, piping arrangement, loading medium (water), measurement oftemperature using pt100(item code: o006a)specifications: input supply: 230 v / 50 hz ac with regulated internal dc power supply unit. sensor: pt100 resistance temperature detector (rtd) probe with stainless steel sheath measurement principle: resistance variation of platinum element with temperature. temperature range: 0 c to
Tender For m and r to talegaon chakan centralized wss replacement of electromagnetic flowmeter with wireless flowmonitoring system on raw water raising main at raw water pumping station talegaon