Get complete information related to latest Fluorescent Choke Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Fluorescent Choke Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Fluorescent Choke Tenders.
Tender For stage contract for supply of key materials required for maintenance of 33/11kv receiving stations along with their lines under the jurisdiction of std bijbehara during the year 2026-27 - electrical store/workshop items/: as per is standards, 11 kv vcb panel board 12 kv, 1250a, 25 ka, outdoor (incommer) as per technical specifications of rec std, 11 kv vcb panel board 12 kv, 1250a, 25 ka, outdoor (outgoing) as per technical specifications of rec std, 33 kv vcb (36 kv, 1250a, 26.2 ka, outdoor type) as per technical specifications of rec std, 33 kv c&r panel with nemurical relays with differential relay ( iec 61850), voltmeter, ammeter, annunciation windows with annunciation relays, 3-phase tri-vector meter -5 amps, dlms compliant as per technical specifications of rec std, 33 kv c&r panel with nemurical relays with out differential relay ( iec 61850), voltmeter, ammeter, annunciation windows with annunciation relays, 3-phase tri-vector meter -5 amps, dlms compliant as per technical specifications of rec std, 33 kv isolator with earthing blade (36kv,1250a, outdoor, 3 poles, 25 ka), 33 kv isolator without earthing blade (36kv,1250a, outdoor, 3 poles, 25 ka), 33 kv outdoor, oil cooled, live tank, single phase , 3 core ct set as per isi specification with accuracy class sp 10 for protection,0.5 for metering & ps for differential with ratio 800-400/5-5-5a ,600-300/5-5-5a , 500-250/5-5-5a, 400-200/5-5-5a (per set of 3 pieces), 33 kv outdoor, oil cooled, copper wound , single phase , pt set with rated primary voltage 33000/ 3 & rated secondary voltage 110/ 3 as per isi specification with accuracy class 0.5 (per set of 3 pieces)., 33 kv lightening arrestors (30 kv, 10ka, station class, zno, porcelain/polymer) gap less(per set of 3 pieces)., 33 kv post insulator (polymer/porcelain 36kv, 170kv impulse), galvanised steel structures(6" g i pipe with top,base & grouting bolts) as per rec, 11kv (e) grade armoured ,almunium,400 sq mm,3-core,xlpe power cable, (std make), 11kv (e) grade armoured ,almunium, 300 sq mm,3-core,xlpe power cable, (std make), 11kv (e) grade armoured ,almunium,240 sq mm,3-core,xlpe power cable, (std make), 11kv (e) grade armoured ,almunium, 185 sq mm,3-core,xlpe power cable, (std make), 11kv (e) grade armoured ,almunium, 120 sq mm,3-core,xlpe power cable, (std make), 2.5 sqmm 2 core control cable armored , copper conductor sheathed pvc insulated multi colour voltage grade 1.1 kv (std make), 2.5 sqmm 4 core control cable armored , copper conductor sheathed pvc insulated multi colour voltage grade 1.1 kv (std make), 2.5 sqmm 6 core control cable armored , copper conductor sheathed pvc insulated multi colour voltage grade 1.1 kv (std make), 2.5 sqmm 8 core control cable armored , copper conductor sheathed pvc insulated multi colour voltage grade 1.1 kv (std make), l t cable 3 1/2 16 sq.mm core armored , al conductor sheathed pvc insulated (std make), 11kv 3 core cable end termination kits of sizes,heat shrinkable of 3m or raychem make required for 3 core xlpe cables, including required size of lugs/thimbles, as per isi specification indoor 400sqmm, 11kv 3 core cable end termination kits of sizes,heat shrinkable of 3m std make required for 3 core xlpe cables, including required size of lugs/thimbles, as per isi specification indoor 300sqmm, 11kv 3 core cable end termination kits of sizes,heat shrinkable of 3m std make required for 3 core xlpe cables, including required size of lugs/thimbles, as per isi specification indoor 240sqmm, 11kv 3 core cable end termination kits of sizes,heat shrinkable of 3m std make required for 3 core xlpe cables, including required size of lugs/thimbles, as per isi specification indoor 185sqmm, 11kv 3 core cable end termination kits of sizes,heat shrinkable of 3m std make required for 3 core xlpe cables, including required size of lugs/thimbles, as per isi specification indoor 120sqmm, 11kv 3 core cable end termination kits of sizes,heat shrinkable of 3m std make required for
Tender For comprehensive maint of b r and e m works like repair maint of lightening protection earthing and replacement of earth strip test point and other miscellaneous works in nad common area and ins tunir at naval station karanja
Tender For supply installation testing and commissioning supply, installation, testing and commissioning of electro atmospheric compensator advance lightening protection system sertec at 710 mva 220 132 33kv gss gladni
Tender For corrigendum : repair/maint of lightening protection of machine control room of light/elevator and e/m installation at certain locations under ge (utilities) udhampur
Tender For corrigendum : repair/maint of eletrical wiring and replacement of old unserviceable flame proof light fittings/fixtures with new led light fitting-fixture, building security light, lightening protection system and allied works at various location under ge (north)
Tender For periodical checks/ maint / repair of day to day complaints of lightening infastructure protection system, earthing infrastructureof labs and other miscellaneous works at afs sulur
Tender For supply and installation of lightening protection system class a type, detail as follows- (1) lightening arrester technology: advance early steamer emission. material: high current discharge stainless steel. international standards: nfc 17- 102. (2) mast material: frp pipe and high-grade aluminium. dimension: 50mm. length: 2 metres frp pipe and 2 metres high grade aluminium mast. (3) down conduct cable: pvc insulated copper cable. dimension: 50 sq. mm, length: 75mtrs (per set) lightning strike counter number of counts: 6 digits. current sensitivity: 1ka to 200 ka, 8/20 & 10/350 micro/sec. induction shunt: 0.5 micro.(4) two (02) no.of maintenance free earth with all required consisting as per specification no. rdso/spn/197/2016 ver 1.0 or latest with all required copper cables and strips. installation of class a type lightening protection should be as per the tan no:- sts/e/tan/3006, version- 3.0 ; dated:- 08.01.2025 (tan specs attached as annexure.) [ warranty period: 30 months after the date of delivery ] ]
Tender For repair/replacement of perimeter lights, garden lights, earthing and lightening protection with allied works at age charduar under ge (n) tezpur