Get complete information related to latest Fuse Plug Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Fuse Plug Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Fuse Plug Tenders.
Tender For procurement of electrical spares and consumables for 220 kv and 33kv switch yard at khodri power station - 245 kv lightening arrester, discharge current 10ka, frequency 50 hz,pressure relief class 40 ka(rms), long duration discharge class 3, m.c.o.v. 56 kv, make: oblum electrical industries pvt. ltd. /cg power and industrial solution ltd. or eq make as approved by engineer in charge., 145 kv lightening arrester outdoor type ,suitable for 145kv system voltage , discharge current 10ka, freq. 50 hz, high current impulse (4/10 s) 100 ka, rated lightning impulse withstand voltage 1.2/50 s - 650 kvp, polymer based (single phase) make-oblum electrical industries pvt. ltd. /cg power and industrial solution ltd,/ htachi / siemens india ltd or eq make as approved by engineer in charge., auxiliary switch (stack) 5no + 5nc, 220v, dc, make: crompton, hitachi or eq make as approved by engineer in charge for 220kv cgl make sf6 circuit breaker., surge monitor/surge counter with leakage current meter suitable for 220 kv lightening arrestor , make: cg power and industrial solution ltd./ oblum electrical industries pvt. ltd., 33kv ct indoor type , 3 core, 15va each, ratio 650-350/1 a + 1a , class 0.2s(2 core metering) & 5p10 (protection), str: 25ka for 3 sec. make siemens, crompton, hitachi or eq make as approved by engineer in charge., 33kv ct indoor type, 3 core, 15va each, ratio 300-150/1 a + 1a , class 0.2s( 2 core metering) & (5p10 protection, str: 25ka, for 3 sec. make siemens, crompton, hitachi or eq make as approved by engineer in charge, control motor, type c21, 2.6 a, 230v ac/dc, o/p 0.3kw, sr. no: 042-901, m/y 03/08, 750/ min. make: kpt shirol or eq make as approved by engineer in charge for 33kv cgl make indoor type sf6 circuit breaker., auxiliary switch 7no+6nc (stack), 250 volt dc, make: crompton, hitachi or eq make as approved by engineer in charge for 33kv cgl make indoor type sf6 circuit breaker., auxiliary switch 8no+ 8nc, 220v, dc, (motor drive ). make: abb/ hitachi or eq make as approved by engineer in charge for 245 kv, abb make isolator., 220 v, dc, close or trip-1 coil ( part no. exin - 400834 - r9)make: abb/hitachi or eq make as approved by engineer in charge for 145kv, abb make sf6 breaker., rectifier 15 a, 220 v, ac (part no. 1hyn-450040p1 ) make: abb/ hitachi or eq make as approved by engineer in chargefor 245kv, abb make isolator, mcb (2 pole,3a, 220v, dc ), over current earth fault relay, mc61a-nx, cat no : mc61anx2200, make: l&t electrical & automation, or eq make as approved by engineer in charge for 33kv sf6 braeker., 33kv busbar support insulator (epoxy) . make: universal engg. corporation,star electrical engg. works or eq make as approved by engineer in charge.(as per sample), epoxy bushing/ fixed contact of "r","y" &"b" phase bottom side for 33kv cgl make panel (as per sample), epoxy bushing/ fixed contact "r","y" &"b" phase top side for 33kv cgl make panel (as per sample), ratech wheel of 33kv sf6 breaker, cgl make, flexible contact of 33kv sf6 breaker finger, cgl make (as per sample), silica gel blue crystal in mesh size of 15 mm to 35 mm duly packed in poly lined moisture proof m s drums/carton, heat shrinkable cable terminal kit for 3- 400mm ,33 kv xlpe cable for outdoor application (make 3m/raychem/ densons)., heat shrinkable cable terminal kit for 3- 400mm ,33 kv xlpe cable for indoor application (make 3m/raychem/ densons)., heat shrinkable cable terminal kit for 3- 185 mm 33 kv xlpe cable for indoor application (make 3m/raychem/ densons)., heat shrinkable cable terminal kit for 3- , 185 mm 33 kv xlpe cable for outdoor application (make 3m/raychem/ densons)., p g clamp deer/panther for 220 kv conductor, p g tclamp deer/ zebra, for 220 kv conductor, p g clamp deer/ trantulla for 220 kv conductor, p g clamp tarantula/ trantulla for 220 kv conductor, p g clamp deer/deer for 220 kv conductor, p g clamp made of aluminum-alloy suitable for zebra to trantulla conductor with 4 nos bolt - n
Tender For supply of 15 amp, dp miniature circuit breaker (mcb), c curve, operating voltage 230/415v, breaking capacity 10ka as per is/iec 60898-1 or latest if. [ warranty period: 30 months after the date of delivery ] ]
Tender For supply of residual current circuit breaker with over current protection(rcbo) 16 amp , voltage rating : 415 v ac, 50 hz , 4 pole , current rating : 16 amp , breaking capacity : 10 ka , tripping characteristic :d- curve , residual current parameters : i) 30 ma residual current ii) impulse current withstand at 8/20 micro second pulses = 3 ka , mounting : din rail similar to the cat no- aug3d401603 of l&t as per rdso letter no : el/7.1.108/sbc/355/non ac coaches dt 14.10.2025 , make-lk, abb, legrand, siemens, schneider or similar. [ warranty period: 30 months after the date of delivery ] ]
Tender For supply of ht and lt breaker spares - sc210290424 mccb, model-dm16, rating -1.6a,40 deg c ui 690v, 50 or 60hz, icu-65ka, ics-75 percent icu, instantan- 19a, is 13947-2 iec 60947-2, utilisation category-a, with limit switch landt or equi , sc210290427 mccb, dn2- 160h3,63a landt or equivalent , sc210170054 mccb,make- landt model dm100,rating-25a 40 deg c,ui- 690v,50 or 60hz,icu -65ka,ics-75 percent,instantan-300a,is 13947-2 or iec 60947-2,utilisation category-a,with limit switch landt or equi , sc210290425 mccb,model-dm16,rating - 7.5a 40 deg c, ui 690v, 50 or 60hz, icu-65ka,ics-75 percent, instan- 90a,is 13947-2 or iec 60947-2,utilisation category -a,with limit switch landt or equi , sc210290426 mccb,model- dm16,rating -5 a,40 deg c ui 690v, 50 or 60hz, icu- 65ka,ics-75 percent icu, instan-60a,is 13947-2 or iec 60947-2,utilisation category, with limit switch landt or equi , sc210170088 mccb,model-dm160,rating -160 a,40xc ui 690v,50 or 60hz, icu-65ka, ics-75percent icu,instan-1920 a,is 13947-2 or iec 60947-2,utilisation category -a,with limit switch landt or equi , sc210290429 mccb ,model- dm100,rating -80 a,40xc ui 690v,50 or 60hz,icu-65ka,ics- 75percentage icu,instan-960 a,is 13947-2 or iec 60947- 2,utilisation category -a,with limit switch landt or equivalent , sc210290428 mccb , model-dn3-400m, rating -400a, ui 415 or 440v, 50 or 60 hz, u 8kv, icu - 50ka, ics 100percent icu, cat - a,is or iec 60947-4,with limit switch landtor equi , sc050130075 power contactor, 3 pole, type no mnx 80, rating 80a, coil voltage 110v ac for chp,with add on block make-landt , sc050130064 u power spring charging motor, 240v ac for chp, make - landt , sc050130084 contactor,3 pole, type no mnx 140,rating 140a, coil voltage 110v ac for chp,with add on block make - landt , sc050130056 contactor, 3 pole, type no mnx 50, coil voltage 110v ac for chp,with add on block make - landt , sc050150366 power contactor mnx265, with add on block,265 a 415 v 3 pole 2no plus 2nc make - landt , sc050150365 power contactor mnx110, 230 ac coil supply,110a,415v, with add on block, 2no plus 2nc make - landt , sc050150367 power contactor, 3 pole, type no mnx 50, with add on block, coil voltage 230v ac for chp. make - landt , sc050150358 contactor,mno 40e, coil voltage 110,4no 4nc make - landt , sc050150359 contactor, mno 31e,coil voltage 110 v ac make - landt , sc050150360 contactor,mno 22e, coil voltage 24v dc make - landt , sc050150364 contactor,mxo 22e,coil voltage 110vdc, ac-15, ue 415v - ie4a,ui 690v, lth-10a make - landt , sc050150363 contactor,mxo 22e, 220vdc, with add on block make - landt , sc050150362 contactor,mx0 40e, 220vdc, with add on block make - landt , sc050150361 contactor,mx0 31e, 220vdc,with add on block make - landt , sc210290423 mpcb, 415v, rotary type, thermal magnetic, 1-1.6 a, mog-h1-0401, make - landt or equivalent , sc210290419 rcbo,415v, 32a,4 pole,100ma make - landt or equivalent , sc210290420 rcbo,415v, 32a,2 pole, 32ma make - landt or equivalent , sc210290422 rcbo,415v, 32a,4 pole,32ma make - landt or equivalent , sc210290421 rcbo, 415v, 32a,2 pole, 100ma make - landt or equivalent
Tender For supply of motor protection circuit breaker (mpcb) for compressor unit 1.1,1.2,2.1 & 2.2 heater 1& 2 current rating 7-10 amp, thermal release range 10-16 amp, class-10, breaking capacity 10ka, 3 pole, voltage rating 415 v ac, conforming to rdso spec. no. rdso/pe/spec/ac/0184-2015 (rev. 1). accepted make as per bom of rdso/pe/spec/ac/0184/2015 rev. (1), revised vide rdso letter no. el/7.1.108/mssbc dated 17.09.2021 (sn 39) abb catalogue noms116-10, legrand, schneider catalogue no. gv2me14, l&t catalogue no. st418980000, siemens catalogue no. 3rv2011-1ja10, eaton catalogue no. pkzm01-10. [ warranty period: 30 months after the date of delivery ] ]
Tender For corrigendum : supply of residual current circuit breaker with over current protection(rcbo) 16 amp , voltage rating : 415 v ac, 50 hz , 4 pole , current rating : 16 amp , breaking capacity : 10 ka , tripping characteristic :d- curve , residual current parameters : i) 30 ma residual current ii) impulse current withstand at 8/20 micro second pulses = 3 ka , mounting : din rail similar to the cat no- aug3d401603 of l&t as per rdso letter no : el/7.1.108/sbc/355/non ac coaches dt 14.10.2025 , make-lk, abb, legrand, siemens, schneider or similar. [ warranty period: 30 months after the date of delivery ] ]
Tender For supply of motor protection circuit breaker (mpcb) for compressor unit and heater unit, current rating 7-10 amp, thermal release range 10-16 amp, class-10, breaking capacity 10ka, 3-pole, voltage rating 415 v ac, conforming to is/iec 60947-2; conforming to rdso spec. no. rdso/pe/spec/ac/0184-2015 (rev. 1); suitable for use in switchboard cabinet of lhb type ac coaches. accepted make & cat. /model no.: rdso-approved make and model as per common bom serial no. 39 of rdso letter no. el/7.1.108/mssbc dated 17.09.2021, make :-abb,legrand,schneider,l&t,siemens and eaton. [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs] ]
Tender For supply of electrical materials for the repair and maintenance of street light as per the boq - details, t-5 power/energy saver 2x24w choke, t-5 power/energy saver 24w ftl tuberod, 2x24 t5-holder, t5 power saver 2x24 fixture acrylic transparent cover, t5 power saver 4x24 fixture acrylic transparent cover, 150w hpsv choke, 150w hpsv lamp, capacitor 33mfd 250vac 50 hz, electronic ignitor suitable for 150w hpsv lamps, 150w holder (porcelain), led driver 50w bis certified, led mcpcb plate 60w, led mcpcb plate 50w, led mcpcb plate 150w, supplyingof isi marked and approved make of moulded case circuit breaker(mccb) suitable for 3phase,3pole,50hz,415 volts, ac supply with respective interrupting capacity(ka) at 415 volts cited against their range standard conforming to is - 8828: 8.1mccb with breaking capacity 25 ka at 415 v: current rating -125 amps & 70% -100% adjustable, supply of sovp device should have single high capacity varistor in the l-n plug and encapsulated spark gap for n-pe, l-n sovp should have a rated voltage of minimum 320v ac to handle indian power supply conditions. sovp should have visual indication on replaceable varistor and spark gap modules as well as a potential free contact on the socket for remote indication. sovp device should be wired up as per tt configuration of wiring in accordance with en 61643-11 standards. both the l-n and n-pe, spds should be rated for handling 30ka of nominal 8/20 s surge current.: sovp for pole light sub feeder panels - type 2 pluggable spd 3+1, rating l-n/n-pe uc 255/320 v in 30/60ka ka, lmax 30ka/60 ka, up 1.5kv, supplying of isi marked and accepted standard of miniature circuit breaker(mcb)ofcseries suitable for 240/415volts,50cycle,10ka value ac supply confirming to is:8828:1996,iec:60898 :2002 but without enclosures: single pole 63 amp., astronomical timer with dst feature, contactor 3 pole 90 amp 50hz 415volts with no-nc contacts, tpn connector 150a, supply of approved make powder coated sheet steel encloser spn mcb db inclusive of busbar,neutral bar,earth bar & two earth terminals etc. complete as per is:13032 (exclusive of mcb & isolator): 8 way double door, supply of sovp device should have single high capacity varistor in the l-n plug and encapsulated spark gap for n-pe, l-n sovp should have a rated voltage of minimum 320v ac to handle indian power supply conditions. sovp should have visual indication on replaceable varistor and spark gap modules as well as a potential free contact on the socket for remote indication. sovp device should be wired up as per tt configuration of wiring in accordance with en 61643-11 standards. both the l-n and n-pe, spds should be rated for handling 30ka of nominal 8/20 s surge current.: sovp for pole light - type 2 pluggable spd 1+1, rating l-n/n- pe uc 230/400 v in 5 ka, imax 10 ka, up 1.2kv, led batten tubelight 20w, supplying of approved make tpn mcbdb metal double door with provision for fpmcb/isolator/rccb/rcbo as incomer and sp mcbs as outgoing inclusive of busbar,neutral bar,earth bar & two earth terminals etc. complete as per is:13032 (exclusive of mcb & isolator ): 8 way (8+24), 8 sq.mm multistrand pvc insulated copper wire bundle 90mtr, 1.sq.mm aluminium single core wire bundle of 100mtr. isi marked, xlpe insulated power cable( conforming is-7098 part-1) 1100 volt grade 2-core isi marked with alu. stranded/solid conductor: 16 sq.mm unarmoured, xlpe insulated power cable( conforming is-7098 part-1) 1100 volt grade 4-core isi marked with alu. stranded/solid conductor: 16 sq.mm unarmoured, xlpe insulated power cable( conforming is-7098 part-1) 1100 volt grade 1-core isi marked with alu. stranded/solid conductor: 25sq.mm unarmoured, wooden ladder 21ft, toolkit set consisting of different sizes l-keys, screw drivers, testers and plier set., taperoll box consisting of 30pcs (conforms to is: 7809 (part 3, sec 1),self extinguishing,protects from electrolytic corrosion,excellent water resistance,suitable for primary ins