Web Analytics Made Easy - StatCounter

Gangway Tenders

Get complete information related to latest Gangway Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Gangway Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Gangway Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :45728533 Due date: 03 Aug, 202603 Aug, 2026 NA
Tender For supply of gangway bridge mounting assembly as per alstom drg. no.1.10113.0.24.120.001.alt 'br' with bridge sheet to drg no 2 10113.0.24.120.101 alt-ar1 material & spec: aisi-304 [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variationpermitted: max 8 lacs ] ]

Central Government/Public Sector

CTN :45736657 Due date: 07 Jul, 202607 Jul, 2026 NA
Tender For supply of vestibule bellow top complete for gangway of lhb type coaches as per icf drg. no.lwsczac-2-5-005, alt.nil with set of bellow securing fasteners to item nos.8, 9 &10 (qty-09 set) conforming to assy.drg.no.lwsczac-2-5-002 alt.f. note: a) packing condition: covered in transparent polythene and packed in suitable length wooden case as shown in icf drg.no.icf/sk-2-5-090. b) material conforming to rdso spec.no.rdso/2007/cg-05(rev.1). [ warranty period: 60 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]

Central Government/Public Sector

CTN :45737354 Due date: 21 Jul, 202621 Jul, 2026 NA
Tender For supply of minor overhaul kits of floor system - train 18 gangway (kit detail - annexure a) as per dellner part no. 1166041-oh-kit [ warranty period: 30 months after the date of delivery ] ]

Central Government/Public Sector

CTN :45709067 Due date: 18 Jul, 202618 Jul, 2026 45.00 Lacs
Tender For repair replacement of internal wiring incl sub main wiring, mcb dbs, bldgs security lights and connected items in pocket 1 to 8 under ge roorkee - taking down old unserviceable point wiring of any description including all fittings and fixtures like switches, sockets, ceiling rose, fan regulator, tubelight,, mirror light,, ceiling light etc complete all as specified and directed., m&l for point wiring with 1.5 sqmm frls-h insulated, unsheathed, multistranded, 1100 volts grade copper conductor cable single core conforming to is:694 along with one run of 1.5 sqmm frls-h insulated copper conductor cable green in colour for continuous earthing drawn through and including medium grade rigid pvc conduit conforming to is:9537 (pt-iii) and its all accessories / junction boxes / inspection covers etc of suitable size but not less than 20mm(od), concealed in wall/ floor etc including provision of earth dolly of suitable size concealed in wall and covered with 3 mm thick phenolic laminated hylam sheet fixed with brass gi screws/ modular cover plate as required for mounting switches, sockets, fan regulator, etc. / modular metal flush box covered with modular frame plate with cover of any size as per site requirement for mounting modular switches, modular sockets, modular fan regulator etc complete all as specified and directed for one light / ceiling fan / exhaust fan / call bell point controlled by one switch, all as per item no 2 here-in-before but one 6a socket point controlled by one switch on independent board, all as per item no 2 here-in-before but one 6a socket point controlled by one switch on same board, all as per item no 2 here-in-before but one 16a socket point controlled by one 16a switch on independent board with 2.5 sqmm wires., all as per item no 2 here-in-before but one wiring in existing conduit for one light / ceiling fan / exhaust fan / call bell point controlled by one switch., all as per item no 2 here-in-before but one one 6a socket point controlled by one switch on independent board, all as per item no 2 here-in-before but one one 6a socket point controlled by one switch on same board, all as per item no 2 here-in-before but one one light point controlled by two no. two way switch complete all as specified and directed, all as per item no. 2 here-in-before but one 16a socket point controlled by one 16a switch on independent board with 2.5 sqmm wires., m&l for sub main wiring along with earth wire with frls-h insulated copper conductor, single core cable drawn through and including medium grade rigid pvc conduit conforming to is:9537 (pt-iii) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 25mm concealed in wall/ floor etc including taking down existing unserviceable sub main wiring of any description complete all as specified and directed for 2runs x 4 sqmm(ph & n) + 1run x 4 sqmm(earth wire):- (note: three runs of copper cable and one run of pvc conduit shall be measured as one unit length), all as per item no 11 here-in-before but 2runs x 6 sqmm(ph & n) + 1run x 6 sqmm(earth wire), all as per item no 11 here-in-before but 2runs x 10 sqmm(ph & n) + 1run x 10 sqmm(earth wire), all as per item no 11 here-in-before but 4runs x 6 sqmm(ph & n) + 1run x 6 sqmm(earth wire), notes for item no. 2.00 to 14.00(i) quoted rate shall deemed to include the cost of cutting chases on wall/floor for concealed conduit wiring and making good with cement plaster, putty and paint to match with the existing surface.(ii) if any beam / column / rock wall is encountered while cutting chases, that particular portion may be provided with pvc casing & capping or surface conduit for drawing cables and surface pvc gang box fully enclosed type for mounting switches, sockets & regulators etc to avoid any damage to the structure. (iii) no cutting shall be done on ceiling for laying pvc conduit for ceiling fan point wiring. surface conduit or pvc casing capping may be

CTN :45337906 Due date: 13 Jul, 202613 Jul, 2026 NA
Tender For corrigendum : supply of intercar gangway mounting. rcf's drawing no. 1 10113.0.24.100.001, alt. no.-r2, without item no. 4. material & specification: as per drawing and conforming to rdso's specification no. rdso/2007/cg-05. rev.1 of sept 2018. [ warranty period: 60 months after the date of delivery ] ]

CTN :45743853 Due date: 13 Jul, 202613 Jul, 2026 NA
Tender For supply of intercar gangway mounting. rcf's drawing no. 1 10113.0.24.100.001, alt. no.-r2, without item no. 4. material & specification: as per drawing and conforming to rdso's specification no. rdso/2007/cg-05. rev.1 of sept 2018. [ warranty period: 60 months after the date of delivery ] ]

CTN :45731442 Due date: 20 Jul, 202620 Jul, 2026 NA
Tender For supply of led light fitting for corridor, doorway, gangway, passenger area (cabin) of non ac lhbcoaches, type b-1,9 watts confirming to rdso spec. no. rdso/pe/spec/ tl/0091- 2016 (rev.1) rcfannexure 1,2& 3 & rcf drg.no.cc76453. [ warranty period: 30 months after the date of delivery ] ]

CTN :45454084 Due date: 07 Jul, 202607 Jul, 2026 NA
Tender For corrigendum : supply of inter-coach gangway without flexible interior system furnishing (including vestibule foot plate) forlhb coaches. gangway material must comply with the fire properties as specified in en 45545 hl-3. installation & commissioning: inclusive, as per mdts-22266 rev-01, packing instruction: pi091 ver. - 3.0. [ warranty period: 60 months after the date of delivery ] ]

CTN :45743702 Due date: 07 Jul, 202607 Jul, 2026 NA
Tender For supply of inter-coach gangway without flexible interior system furnishing (including vestibule foot plate) forlhb coaches. gangway material must comply with the fire properties as specified in en 45545 hl-3. installation & commissioning: inclusive, as per mdts-22266 rev-01, packing instruction: pi091 ver. - 3.0. [ warranty period: 60 months after the date of delivery ] ]

CTN :45714236 Due date: 27 Jul, 202627 Jul, 2026 NA
Tender For supply of intercar gangway bridge mounting complete for lhb/eog coaches to icfs drg. no. lwsczac-2-5-054, col-i. alt-f, with bridge sheet to icfs drg. no. 534-2-5-026 alt. a to aisi-304 [ warranty period: 30 months after the date of delivery ] ]
 Loading, Please wait...

Connect us via What's Up