Web Analytics Made Easy - StatCounter

Gas Charging Tenders

Get complete information related to latest Gas Charging Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Gas Charging Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Gas Charging Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :45636287 Due date: 03 Jul, 202603 Jul, 2026 9.00 Lacs
Tender For corrigendum : annual maintenance contract for medical gas pipeline system and allied works at skims mch bemina

Central Government/Public Sector

CTN :45726591 Due date: 18 Jul, 202618 Jul, 2026 NA
Tender For repair/ maint of air conditioning systems alongwith its connected accessories at kashmir house under ge new delhi - servicing of window type ac 1.5/2 ton capacity of any make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directed. note: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 1.00 above but split type ac of any type and 1.5/2 ton capacity complete all as specified and directed, servicing of cassette type ac 3.5 to 4.0 ton capacity of any make / model with indoor and outdoor unit by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing, oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directednote: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 3.00 above but tower type ac of 2.0 to 4.0 ton capacity of any make / model any type and 1.5/2 ton capacity complete all as specified and directed, s&f in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 volt for ac upto 4.00 ton complete all as specified and directed, m&l for checking the leakage by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas r-12/22/134a for water cooler, split type/window type ac/ deep freezer /refrigerator any size any capacity as on site complete all as specified and directed by engr-in-charge., m&l for replacement of reverse valve system suitable to 1.5/2 ton split/window ac for heating option (gas charging shall be paid and measured under respective item) complete all as specified and directed, supply & charging gas refrigerant r-22 /410 a/ or as existing to window type/split type/cassette/package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer-in-charge, m&l for repair of unserviceable pcb suitable for non inverter split type ac 1.5/2 tr and fixing the same complete all as specified and directed by engineer-in-charge., m&l for opening and taking down existing unserviceable pcb along with display unit and repairing & refixing of pcb along with display unit suitable for indoor unit of inverter ac of capacity1.5/2 ton split type ac complete all as specified and directed by engr-in-charge., m&l for opening and taking down existing unsv pcb and reparing & refixing of pcb suitable for outdoor unit of 1.5/2 ton split type ac inverter ac complete all as specified and directed by engr-in-charge., m&l for repair of unserviceable pcb of cassette/ tower ac of capacity 3.5 to 4.0 tr for both indoor/ outdoor units and refixing the same in respective units including opening & taking down existing unsv pcb complete all as specified and directed by engineer-in-charge., s&f pcb of non inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of cassette/tower ac of capacity 3.0 to 4.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by enginee

Central Government/Public Sector

CTN :45726596 Due date: 18 Jul, 202618 Jul, 2026 NA
Tender For repair/ maint of air conditioning systems alongwith its connected accessories at hq ids under ge new delhi - servicing of window type ac 1.5/2 ton capacity of any make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directed. note: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 1.00 above but split type ac of any type and 1.5/2 ton capacity complete all as specified and directed, s&f in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 volt for ac upto 4.00 ton complete all as specified and directed, m&l for checking the leakage by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas r-12/22/134a for water cooler, split type/window type ac/ deep freezer /refrigerator any size any capacity as on site complete all as specified and directed by engr-in-charge., m&l for replacement of reverse valve system suitable to 1.5/2 ton split/window ac for heating option (gas charging shall be paid and measured under respective item) complete all as specified and directed, supply & charging gas refrigerant r-22 /410 a/ or as existing to window type/split type/cassette/package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer-in-charge, m&l for repair of unserviceable pcb suitable for non inverter split type ac 1.5/2 tr and fixing the same complete all as specified and directed by engineer-in-charge., m&l for opening and taking down existing unserviceable pcb along with display unit and repairing & refixing of pcb along with display unit suitable for indoor unit of inverter ac of capacity1.5/2 ton split type ac complete all as specified and directed by engr-in-charge., m&l for opening and taking down existing unsv pcb and reparing & refixing of pcb suitable for outdoor unit of 1.5/2 ton split type ac inverter ac complete all as specified and directed by engr-in-charge., s&f pcb of non inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 6.0 mm (1/4") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 13.0 mm (1/2") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 9.0 mm (3/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 16.0 mm (5/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in repair drain pipe of any size suitable for split ac of capacity 1.5/2/3.5/4 tr as per sample complete all as specified and directed., supply only in replacement cordless remote for inverter type acs hot & cool suitable for 1.5 ton ac as per sample complete all as specif

CTN :45729683 Due date: 07 Jul, 202607 Jul, 2026 4.19 Crore
Tender For construction of 200 bedded rural hospital with trauma care unit at manor taluka dist palghar (sitc of medical gas pipeline system).

CTN :45718963 Due date: 24 Jul, 202624 Jul, 2026 1.30 Crore
Tender For liquid medical oxygen gas capacity 20 kl

CTN :45714317 Due date: 15 Jul, 202615 Jul, 2026 NA
Tender For supply of cassette and split ac c c - cassette ac split ac , itc of ac , copper pipe, electrical cable, drain pipe , ms stand, indoor brackets, gas charging , ventilation work

CTN :45478155 Due date: 01 Jul, 202601 Jul, 2026 NA
Tender For corrigendum : cs/rmo/2026/2089-90/ac/washing - items, ac compressor 1-5 ton, ac compressor 2 ton, ac outdoor gas bal, ac indore fan motor, ac outdoor fan motor, ac condensers, ac gas charging, ac condenser outdoor mesh, connector ac, ac sensor indore, ac running capacitor, ac service charge, water cooler fan motor, water cooler compressor, water cooler condenser, water cooler mash, water cooler riley, water cooler over load, water cooler running capacitor, water cooler service charge, water cooler gas filling charge, washing machine spine timer, washing machine wash timer, washing machine wash motor, washing machine spine motor, washing machine bello, washing machine gear box, washing machine capacitor, washing machine service charge, refrigerator compressor, refrigerator rile, refrigerator overload, refrigerator thermometer, refrigerator senseor, refrigerator wall, refrigerator fan motor, refrigerator bimetal, refrigerator time, refrigerator pcv, refrigerator fuse, refrigerator door swath, refrigerator gas charge, refrigerator service charge, ac pcv, ac stand for spilit ac, ac stand for window ac, copper pipe for spilit ac per feet, copper pipe for window ac per feet, spilit and window ac remote

CTN :45712200 Due date: 10 Jul, 202610 Jul, 2026 NA
Tender For supply of required materials & spare for rectification in pac units at haldia lpg import terminal - refrigerant gas r-407c, drier, filter, r410a, dml 305, icom temper+humid.sensor 276810, fan, axial, 230 vac, 700 w, 6000 (m ^ 3) / h 1300 rpm, 500 dia × 161 mm, ip54, rohs, nitrogen cylinder, 02 use, for gas charging, da use, for gas charging, multiple leakage rectification in pac outdoor units along with brazing and transportation of cylinders, display, small, icom, 180633g3r0 for air conditioning machine, control board, icom, large, 419661g2, for air conditioning machine, icom temper+humid.sensor 276810, fan, axial, 230 vac, 700 w, 6000 (m ^ 3) / h 1300 rpm, 500 dia × 161 mm, ip54, rohs, control board, icom, large, 419661g2, for air conditioning machine, icom temper+humid.sensor 276810

Central Government/Public Sector

CTN :45163037 Due date: 01 Jul, 202601 Jul, 2026 NA
Tender For bid to ras providing of customized amc/cmc for pre-owned products - medical gas pipeline system; --; comprehensive maintenance contract (cmc); not applicable; yes

CTN :45506168 Due date: 15 Jul, 202615 Jul, 2026 2.26 Crore
Tender For corrigendum : tender for supply of temperature sensor-transmiter tt 001 hbs-5-4425-1 , temperature sensor/transmiter tt 001& 2 hbs-5-4425-2 , temperature sensor tt 002 hbs w/o no 64032 , temperature transmiter tt 002 hbs w-o no 64032 , carbon brushes 59 kw , bearing set 59 kw nu215 &nup215 , isolator switch 3 pole 25a , programmble controller , heating element , motor 22kw1138 , humidistat1163 , main switch ot80f31226 , ovrld gv3l501234 , pressure switch1980 , differential pressure switch adps03 50-500 pa , differential pressure switch adps05 200-1000 pa , differential pressure switch adps07 1000-4000 pa , actuator gga326.1 e-ha 230v , ac-dc converter 24v 5a , main switch ot63f3 , main switch ot100f3 , main switch ot125f3 , overload relay gv2-p16 9-14 a , overload relay gv2-rt08- 2.5-4 a , terminal connector 2 , 5 mm2 , terminal connector 4 mm2 , terminal connector 6 mm2 , terminal connector 10 mm2 , terminal connector 16 mm2 , terminal connector 25 mm2 , hmi display 7inch x2 pro new type , hmi cable cab 103-3m , plc module fx3u-485-adp-mb rs485 , actuator , pressure meter for citadel , compressor-motor flexible coupling insert 61-0920 , compressor rt450al-oil filter replacement kit 61-9916 , gasket copper-1-4inch flare , fan belt , dust filter , nbc cart stanag 44471157 , filter1414 , filter1424 , filter1430 , filter1436 , filter1442 , filter1448 , fan bearing , impeller1042 , filter2188 , filter2189 , filter2192 , filter2194 , motor bearings drive end type 6309 , motor bearings non drive end type 6204 , motor bearings non drive end type 6208 , motor bearings non drive end type 6210 , motor bearing plummer block 0048 , motor bearings - block blns0050 , motor bearings - block blns0030 , 2 stage combi g4 pre filter and f9 fine filter 600 m-3h , 2 stage combi g4 pre filter and f9 fine filter 900 m-3h , 2 stage combi g4 pre filter and f9 fine filter 1800 m-3h , 2 stage combi g4 pre filter and f9 fine filter 2700 m-3h , 2 stage combi g4 pre filter and f9 fine filter 3600 m-3h , flexible hose 50mm nb , flexible hose 65mm nb , flexible hose 100mm nb , flexible hose 25mm nb , flexible hose 32mm nb , flexible hose 25mm nb , flexible hose 32mm nb , thermostatic expansion valve body , replacement motor , replacement motor , compressor tool kit xjf 95s , gas charging hose , tempreture humidity meter
 Loading, Please wait...

Connect us via What's Up