Tender For corrigendum : supply of procurement of air conditioning spares for various departmental hemms of mcl basundhara area : : 5 =5 = -expansion , thermostat , switch rotary 3 speed , switch toggle on on , fillter air , evaporator core assy , blower motor assly , receiver drier , switch binary , compressor , hose 50 ft , hose , 6 female 90 dig , ftg 6 male 90 deg , 6 male straight , 8 female 90 dig charging put , 8 female 90 dig , 10 female 90 dig charging port , 10 male straight , 90 female o ring , ftg 10 male 90 deg , circuit breaker 30amp 24v , relay 24v , fan motor assy10 in dia 24 v , motor double blower 24 v , module assy electronic thermostat , filter foil framed , core combi htr evaprator r 9750 , fan motor assy 24v , fan motor assembly , motor blower assy 24v , compressor oil 250ml sp15 , refrigerant gas , condenser assy
Tender For tender for supply of spares for gtg system - relay finder 44.62 , 24vdc , 10a dpdt 2co , relay base for finder 44.62 , 24vdc relay , transducer power for gtg avr , varistor rv5/50 for contactor gtg avr , capacitor 1000mf , 450vdc gtg avr , diode bridge 35a , 36mt120 gtg avr , contactor field gtg avr , add on blk abb contactor field gtg avr , converter usb to rs232/485/422 sc11u , moxa converter u port rs232 to usb , fiber to fast 4 port ethernet converter
Tender For procurement of spares for prabhu make nflp auto transformer starter - diode by255 for vacuum contactor part no ht200c or equivalent , vacuum contactor closing coil 110v dc part no ht203 or equivalent , vacuum contactor holding coil 110v dc part no ht204 or equivalent , copper terminal bar for o g terminal part no ht701a or equivalent , brass cable gland complete with c. i clam part no ht1600 or equivalent , intrinsically safe pilot panel complete part no ht3000 or equivalent , isolator 400 amp, 6. 6 kv part no ht100a or equivalent , vaccum contactor 400amp, 6. 6kv grade part no ht200 or equivalent , bottle for vaccum contactor 400amps. 6. 6kv part no ht202 or equivalent , dmc insulator for i c,t g,o g and power fuse 6. 6kv part no ht700a or equivalent , timer electronics 3sec to 3minon delay part no ht2004a or equivalent , contactor tp,12 amps ac3 duty fitted with 110 v dc coil part no ht200a or equivalent , microcontroller based ct operated ct sec. 5a motor protectionrelay having following features with display over load protection, single phasing, part no ht900e or equivalent , oil cooled copper wound auto transfrmr starter part no tr1100kw or equivalent ) /bid number: gem/2026/b/7289425 * /dated & & / bid document1 / 20
Tender For supply of proc of r2 spares out of mt grant 79 e e -front wind shield , front wind screen weather strip , electric fan assy , suction hose assy , mud flap , hand brake cable , brake hose front side , assy parking brake cable , intermediate brake hose , wiper blade front , wiper blade rear , cable assy hood lock release , assy pivot bush , timing belt , air filter element , hose air , ac belt , alternator belt , bearing assy rear , oil seal raer axle shaft , gasket cyl head cover , relay 40 a , relay 12v 20 a , fuse 150 a alternator , cam shaft oil seal , glass side window lh
Tender For tender for supply of ht cable -m and l for searching fault location of ht ug cable 11000 volts laid in trenches ducts with the help of electronic fault locating machine comprising of surge generator pulse echo fault locator with frequency distance calculator etc incl transportation of machinery excavation in normal soil strata exposing the cable fault removal of deteriorated portion of the cable treating of cable of any size including disconnecting and re fixing cables with lugs as per direction of engineer in charge note a charges of cable fault locator and dg set including transportation charges deemed to be included in the quoted rate b necessary testing of cable after making joint will be deemed to be including in the cost of relevent item , supply jointing and testing indoor type cold shrinkable end termination cable joint including all material and accessories suitable for 3 core x 120 minus 185 sqmm xlpe cable of 11000 volts e grade complete all as specified and directed note cost of cutting of existing end termination joint deemed to be included in unit rate , m and l for cable jointing kit for 11 kv earthed grade cable for straight through cold shrink type complete with joining material and accessory suitable for 120 to 185 sqmm 3 core xlpe armored aluminum conductor cable complete all as specified and directed , supplying and laying in repair xlpe insulated screened pvc bedded galvanized steel strip or wire armoured , electrical power cable heavy duty with aluminum conductor 11000 volts grade cross sectional area 120 sqmm x 3 core complete all as specified and directed , supply and fixing in repair mccb 400 amps 3 pole 415 volt 36 ka including under voltage over voltage relay with adjutable thermal setting 80% minuse 100% all as specified and directed , m and l for complete repairing serviceing of ht 11 kv vaccum circuit breaker vcb after disconnecting of all incoming and outgoing connection checking finding of the defective spare parts removing of all moisture content with suitable grade chemical replacement of rusted nuts bolts and washer replacement of all unserviceable post insulator and repair of all busbar joints and covered with ht insulation tape complete external surface as per existing colour and quality replacemnt of all defective internal ac dc circuit wiring repair servicing of breaker trolly including motorized operating mechanism ct pt power pack and calibration of triping relays system and tripping mechanism for regulating the fault flow over current earth fault differential in sequence from down streem to receiving sub stn for accuracy and effective functioning of vcb complete all as specified and as directed note nuts bolts washer cleaning material insulation tape copper wire for circuit wiring and defective ht 11 kv 2 amp fuse carrier oiling greasing to charging spring replacement of hrc fuse 110 220 volt 5 amps setting of over current earth fault relays complete other minor items for repair of breaker shall be deemed in qouated rate replacement of major unserviceable spares accessories shall be measured and paid separately under relevant items , supply and fixing heater 230 volts ac 60 watt for 11 kv ht vcb panel complete all as specifed and as directed make heatco vileco electrical , supply and fixing in replecement of spring charging gear for 11kv vcb panel suitable for 630 400 amp complete all as specified and directed , supply and fixing vacuum interputer for ht11 kv vcbs 630 400 amps brakding capacity 13point 1 ka suitable for alstom make vcb complete all as specified and as directed , taking down and repairing overhauling of air break gang operated switch with do fuse unit 200 amp 400 amp capacity triple pole mechanically operated mounted on insulators and steel frame installed vertically horizontally replacement of broken worn out components oiling and greasing of mechanical moving parts smoothing and polishing of electric contacts with providing conducting jelly of contacts refixed the sam
Tender For supply of boq 158 aws spares c c -x2-aws-90kva-5945720501577 bdl part no 1840220200023 single c-o relay mtrl no 10580483 , x2-aws-30kva-6110997018057 bdl part no 1840245200026 automatic voltage regulator mtrl no 10580360 , x2-aws-90kva-5945016815627 bdl part no 1840220200022 2 c-o relay base mtrl no 10580481 , z1-aws-tst-5910720504033 bdl part no 1840203200062 filter capacitor 3300mfd-315v mtrl no 10581185 , z22-aws-aal-5996720502564 bdl part no 1840216200035 bldc amplifier assy mtrl no 10580198 , x2-aws-90kva-6110997018057 bdl part no 1840220200037 automatic voltage regulator mtrl no 10580511