Tender For design, manufacture, testing, supply (fixing & testing) and commissioning of 447nos of numerical relay (numerical over current and earth fault relay with over load protection) required for 11kv exclusive ip feeder breakers of various 66/11kv s/s coming under transmission (operations) mysuru zone. the numerical relay shall be fixed to respective 11kv exclusive ip feeder breakers by replacing existing over current & earth fault relays with suitable wiring / blanking plates.
Tender For supply of spares for caldyne (now m/s exide industries ltd) make battery charger installed at chp, stps, suratgarh--- avr/acr module for float, type no. 137/3p/fc , avr/acr module for boost, type no. 137/3p/fc , potentiometer 10k ohm/30w , ti 300trip fuse with micro switch , dc uvr/ovr module with card, static type, type no. 69 , dc uvr/ovr card, static type, type no. 69 , fbcor module, static type, type no. 37 , ocr module, static type, type no. 46 , ac sfr module, static type , iprc module, type no. 46 , sfr module, static type, type no. 35 , earth fault relay module, static type, type no. 55 , annunciation module, static type, type no. 62+48+128 , auto equalizing relay card , bleeder network, 1000 ohm/250w
Tender For corrigendum : supply of service 11 kv ht panel as per sepcifications , sf new mineral oil for panel etc as per sepcifications , calibration relay etc as per sepcifications , replacement digital ammeter for ht panel , replacement digital voltmeter for ht panel , replacment ryb ind lamp led type in ht panel , sf 2a hrc fuselink in ht panel , servicing 1500kva dry type transformer as per sepcifications , servicing 2 runs 2500a tpn bustrunking as per sepcifications , service mv lt panel with 2500a 4p acb 3 nos as per specifications , service mvlt panel with mccb incoming as per specifications , checking and repair of em intelocking , dismentaling 3.5 sq mm 240 or 300 sq mm al cable as required , pf adaptor box aprx 1.5 ft x 1.5 ft x 1.5ft of 16swg ms sheet as reqd , pvdg panel module door key as reqd , pvd and fixing operating handle for 250a 4p changeover as reqd , replacement 160a hrc fuse with base in extg cap panel , replacement 3p 50kvar cap duty contactor in extg cap panel , replacement 25sq mm cu lead wire 1ft length in extg cap panel , checking etxg 2no 25kvar cap bank and fault repair reinstallation , dismentaling uv protection connections as reqd , replacement digital ammeter for lt panel , replacement digital voltmeter for lt panel , replacment selector switch in lt panel , replacment ryb ind lamp led type in lt panel , sf 2a hrc fuselink in lt panel , sf 32a hrc fuseling incl removing faulty item from lt panel as reqd , sf 63a hrc fuseling incl removing faulty item from lt panel as reqd , sf 100a or125a hrc fuseling incl removing faulty item from lt panel as reqd , sf 250a hrc fuseling incl removing faulty item from lt panel as reqd , sf new 5 or 6 amp piano switch in replacement of faulty item , sf new 5 or 6 amp 3pin socket outlet in replacement of faulty item , sf new 15 or 16 amp piano switch in replacement of faulty item , sf new 15 or 16 amp 6pin socket outlet in replacement of faulty item , rewinding ceiling fan motor , sf 4ft 20w led fitting against faulty fitting , service of 750kva dg set as per specification , service dgset control panel 1250a 4p acb as per specification , repacement ryb ind lamp in dg set panel , repacement digital ammeter in dg set panel , earthing testing in existing earth pits and report submission