Get complete information related to latest Hdpe Pipe Laying Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Hdpe Pipe Laying Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Hdpe Pipe Laying Tenders.
Tender For repair and rectification of w/s leakages found in ac pipe c-15 including excavation, bailing out of water providing and fixing of ci detachable joints c-15 suitable for ac pressure pipe marked with is: 8794 for use with ac pipes complete with 2 no. rubber ring marked with is:5382 & is:10292 and appropriate no. of nuts and bolts marked with is 1363 including carriage in all respect and including cost of ac pressure pipe c-15 as per is: 1592 & 2003 complete in all respect to the satisfaction of the engineer-in-charge/ac 100 mm pipe class-15/ at bawwa ,repair and rectification of wis pipeline leakages found in pvc pipe including excavation, bailing out detachable joint suitable for 6kg cm2 pressure pipe marked of nuts and bolts marked with is 1363 the satisfaction of water providing and fixing of pvc with is: 8794 for use with pvc pipe complete with 2 no. rubber ring marked with is and appropriate no. including carriage in all respect and including of pvc pipe isi marked complete in all respect to of the engineer-in-charge/ac 200 mm i/d class-25/at bawwa ,repair of 150mm sluice valve including making m.s spendle, g.m. chuck nut, new chimta, nut bolt, rubber jain, glain dori, grease sluice valve opening and fitting at site, carriage charges from site to work shop and work shop to site including labour charge complete as per specification of engineer-in-charge complete in all respect, /150 mm sluice valves repair / at bawwa
Tender For repair and rectification of w/s pipeline leakages found in pvc pipe including excavation, bailing out of water providing and fixing of pvc detachable joint suitable for 6kg cm2 pressure pipe marked with is: 8794 for use with pvc pipe complete with 2 no. rubber ring marked with is and appropriate no. of nuts and bolts marked with is 1363 including carriage in all respect and including of pvc pipe isi marked complete in all respect to the satisfaction of the engineer-in-charge/ac 200 mm i/d class-25/ at gugodh ,repair of 150mm sluice valve including making m.s spendle, g.m. chuck nut, new chimta, nut bolt, rubber jain, glain dori, grease sluice valve opening and fitting at site, carriage charges from site to work shop and work shop to site including labour charge complete as per specification of engineer- in-charge complete in all respect, /150 mm sluice valves repair / at gugodh ,repair of 200mm sluice valve including making m.s spendle, g.m. chuck nut, new chimta, nut bolt, rubber jain, glain dori, grease sluice valve opening and fitting at site labour charge completes as per specification of engineer-in-charge complete in all respect, /200mm / at gugodh
Tender For repair/maint of air cooled ac plants, chiller, condenser pump, hot water boiler, ahu, water colled ac plants, motor, hwg and ahu alongwith connected items at akash complex/tech area at dappar under age(i) dappar - material and labour for servicing / cleaning of air cooled ac plants of 50 tr capacity, chiller unit, cleaning and washing of cooling coil with fins using a chemical c-shine (alkaline coil cleaner and brightener) and testing the unit (once in a three months) complete all as specified and as directed by engineer-in-charge. location :- akash air cooled ac plants(once in a three months), material and labour for descaling of complete condenser units for central/ package type ac plants of condenser unit of water cooled ac plantac plant upt to 40 tr capacities by means of adding descaling chemical solution (hcl) or equivalent into the cooling tower sump as per requirements, and running the plant pump continuously till all the scale of pipes/shell are removed including removing side covers of condenser and cleaning the water tubes by means of nylon brushes till the scaling is removed and refixing of covers including replacement of neoprene rubber gasket and refixing pipe connection etc. to entire satisfaction of engineer-in-charge complete all as specified and as directed by engineer-in-charge. location :- old, 3ac igloo ac plant and new ac plant (once in a three months), material and labour for cleaning of cooling tower existing size, water basin and makeup tank with the help of chemical and nylon brush, removing and refixing of pvc finches after washing, cleaning of condenser pipe line ( inlet and outlet) including painting of out side of cooling tower with inlet and outlet pipe line with one coat synthetic enamel paint of colour approved by engineer in charge and inside painting of water tank of cooling tower using water proof black japan paint one coat including changing of unserviceable pvc guard, water distibutor, pvc pipe, and all connected minor items of up to 100 tr capacity of the ac plants at different locations complete all as specified and as directed. location :- old and new ac plant, material and labour for servicing of cooling coils and air filters of ahus intalled at air conditioning plant by removing air filters and fixing after cleaning with air blower and water and cleaning agent , cleaning of cooling coilwith wire brush and air blower and water spray pump after spraying scale gun or equivalant chemical suitable for aluminium fins and straighting the fins of cooling coil by using suitable brush for any capacity of ahu complete all as specified and as directed by engineer-in-charge. locaton :- new ac plant, old ac plant , 3 ac igloo ac and akash ac plants akash, material and labour for servicing / cleaning and testing of electrically operated pan type humidifier capacity 9 kw alongwith all necessary items fitting and all suitable / all necessary electrical wiring from electrical panle to humidifier complete all as specified and as directed by engineer-in-charge. location :- akash ac plants, material and labour for servicing / cleaning and testing of pressurization unit in cold water line ( psu-225 as per site) alongwith all necessary items fitting and all suitable / all necessary electrical wiring complete all as specified and as directed by engineer-in-charge. location :- akash ac plants, material and labour for servicing / cleaning and testing of pressurization unit in hot water line ( psu-225 as per site) alongwith all necessary items fitting and all suitable / all necessary electrical wiring complete all as specified and as directed by engineer-in-charge. location :- akash ac plants, material and labour for servicing , cleaning , and greasing , chiller , hwg pumps , ahu and ct motors alongwith all necessary minor items/ fitting i.e bearing , star coupling , screws , nuts and bolts etc complete all as specified and as directed by engineer-in-charge. location :- new ac plant , old ac plant and air coole
Tender For repair / maint of split acs 2/1.5 ton , windows acs 2 / 1.5 ton , voltage stablizers and connected items installed at command hospital (wc) and other various location in aor of age e/m ch - servicing of split type ac of capacity 2/ 1.5 tr after disconnecting all incoming and outgoing electric connection, water drain pipe line connection etc. and wash with approved chemical mixed water with the pressure pump, after servicing cleaned all the disturbed area and reassembling the water/electric connection and testing for entire satisfaction of engr-in-charge., all as per item no. 1 here-in-above but window type ac 2/1.5 tr capacity., supplying and charging of refrigerant gas r-22 only after vacuuming dehydration, leak testing of the system as per standard practice testing for proper cooling effects and satisfactory performance complete all as specified and as directed by engr-in-charge for room split/window type ac of capacity 2/1.5 tr., all as per item no: 3 above but gas r-32, all as per item no: 3 above but gas r-410a., all as per item no: 3 above but gas r-134a., taking out defective capacitor of capacity 50+6 mfd after disconnecting all incoming and outgoing electric connection including supply & fix new capacitor on same place and testing complete all as specified and as directed by engr-in-charge, all as per item no:7 here in above but of capacity 45+4 mfd ., all as per item no:7 here in above but of capacity 45 mfd ., all as per item no: 7 here in above but of capacity 6 mfd ., all as per item no: 7 here in above but of capacity 4 mfd ., supply & fixing as in replacement copper pipe 1/2" for liquid line including fittings and testing complete all as specified and as directed by engr-in-charge., supply & fixing as in replacement copper pipe 1/4" for liquid line including fittings and testing complete all as specified and as directed by engr-in-charge., supply & fixing as in replacement copper pipe 5/8" for liquid line including fittings and testing complete all as specified and as directed by engr-in-charge., supply & fixing as in replacement copper pipe 3/8" for liquid line including fittings and testing complete all as specified and as directed by engr-in-charge., supply and fixing of insulation foam for copper pipe of size 1/2" after removing old one., supply and fixing of insulation foam for copper pipe of size 1/4" after removing old one., supply and fixing of insulation foam for copper pipe of size 5/8" after removing old one., supply and fixing of insulation foam for copper pipe of size 3/8" after removing old one., supply and fixing as in replacement of pvc flexible pipe 15 mm dia including any fittings as required complete inclusive of any type of leakage testing., all as per item no: 20 above but pipe of 20 mm dia., supply and fixing as in replacement of pvc water drain pipe 25 mm dia complete inclusive all fittings and any type of leakage testing., material and labour for sub main wiring with 2 x 2.5 sqmm +1 x 2.5 sqmm single core flame retardant pvc insulated unsheathed cable with stranded copper conductor drawn in and including heavy grade frlsh pvc concealed conduit isi marked with all accessories on walls and making good the disturbed surfaces including all conduits fittings, clamps guittes etc for earth dbs and boxes with proper thimbles all as directed by engr-in-charge. note :02 run of 2.5 sqmm , 01 run of 2.5 sqmm cable and 01 run of conduit shall be measured as one unit and paid accordingly., all as per item no: 23 here in above but of size 2x 4 sqmm +1x 4 sqmm., m&l cutting chases, pinning in stone concrete block or slab walls & making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring ,etc., and making good, cutting exc. 10 cm girth., supply and fix as in replacement of rigid non-metallic pvc conduit of size 20
Tender For repair/ maint of air conditioning systems alongwith its connected accessories at hq ids under ge new delhi - servicing of window type ac 1.5/2 ton capacity of any make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directed. note: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 1.00 above but split type ac of any type and 1.5/2 ton capacity complete all as specified and directed, s&f in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 volt for ac upto 4.00 ton complete all as specified and directed, m&l for checking the leakage by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas r-12/22/134a for water cooler, split type/window type ac/ deep freezer /refrigerator any size any capacity as on site complete all as specified and directed by engr-in-charge., m&l for replacement of reverse valve system suitable to 1.5/2 ton split/window ac for heating option (gas charging shall be paid and measured under respective item) complete all as specified and directed, supply & charging gas refrigerant r-22 /410 a/ or as existing to window type/split type/cassette/package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer-in-charge, m&l for repair of unserviceable pcb suitable for non inverter split type ac 1.5/2 tr and fixing the same complete all as specified and directed by engineer-in-charge., m&l for opening and taking down existing unserviceable pcb along with display unit and repairing & refixing of pcb along with display unit suitable for indoor unit of inverter ac of capacity1.5/2 ton split type ac complete all as specified and directed by engr-in-charge., m&l for opening and taking down existing unsv pcb and reparing & refixing of pcb suitable for outdoor unit of 1.5/2 ton split type ac inverter ac complete all as specified and directed by engr-in-charge., s&f pcb of non inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 6.0 mm (1/4") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 13.0 mm (1/2") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 9.0 mm (3/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 16.0 mm (5/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in repair drain pipe of any size suitable for split ac of capacity 1.5/2/3.5/4 tr as per sample complete all as specified and directed., supply only in replacement cordless remote for inverter type acs hot & cool suitable for 1.5 ton ac as per sample complete all as specif
Tender For procurement of spares for cooling towers (make-paharpur cooling towers limited) installed for cooling of circulating water for air compressor system and air conditioning system at u 7 and 8, ssctps, rvun, suratgarh - requirement of spares for cooling towers installed for cooling of circulating water for air compressor system in ahp area, model no. 6405m, grdr 20t rt-2.71:1 68-4592-1, fan assy 60in h-3-6 p85- (pcu-2/c) 3118-2, fill pack pc-47 p83-3128-1, d/s 6q cli 460 gb1.1/8 mb 38, spray nozzle p86-1082-3pp, elim pack stack pc-47 96-2034-17, branch pipe 50nb p85-1142-6, d/s coupling 6q with nbm insert gear side(gear shaft hole dia: 35 mm), d/s coupling 6q with nbm insert motor side(motor shaft hole dia: 48 mm), louvers, requirement of spares for cooling towers installed for cooling of circulating water of ac system in ca area, model no. 22103 for item s. no. 2.01-2.06 and model no. 3861 for item s. no. 2.07-2.10, fill sht mx75-8.1 lev p89- 4049-7, fill sht mx75-8.1 lev p89- 4049-8, fan assy 96in h-3-6, grdr 20t cc2, kit d/s 6q i nbm insert (rubber bush withhardware for drive shaft coupling), s.t. nozzle 68 3738-0xx pp, fill sht mx75-8.1 leh 86-4500-3, fill sht mx75-8.1 leh 86-4500-4, brg hsg assy sr118se, fan assy 54in h-3-6, requirement of stitching material for repair of damaged of frp structure of cooling towers, frp stiching material (fibre resin, fibre matstraid, mekp, cobalt, brush, chalk powder etc.)
Tender For supply of 10 pair ug jf communication cable , station line module analog board , l3 poeplus managed switch with integrated sfp transceiver modules , 12 core sm ofc cable , hdpepipe , 2 pair pvc telephone cable , cat 6 utp cable , pvc conduits including laying of cat6 cable and 2 pair pvc telephone cable 2000 mtrs , 24 port loaded cat 6 utp patch panel , rj11 rj45 i o boxes , 4 port spu lpu , 5a 0 25a glass fuses , cable route markers joint indicators , excavation of trenches cat 6 utp cable 2150 mtrs , laying of 10 pair armoured communication cable laying of hdpepipelaying of ofc cable 3250 mtrs , fixing and dressing of 12 nos of 6u network racks , 24 port fiber liu , 9u network rack , ofc patch cords of 2m length , cat6 patch cords 0f 2m length , provision of additional structured cabling in 10 work centers of cas as per scope of work , shifting of network rack end termination of telephone and cat6 cables and dressing of all cables splicing etc in e f facility , 20 pair weatherproof telephone junction boxes , open stage hfa ip phones with perpetual gateway licenses , digital handsfree telephone cli , installation commissioning programming and testing of above all items and provision of additional structured cabling for 01 year for any newly added
Tender For supply of ac compressor repair , wheel alignment balancing , ac repair , ac repair 1 , ac gas refilling and oiling and pipe flashing , service charge
Tender For supply of tata safari compressor and ac gas pipe repair , ciaz wiper blade motor repair , fly wheel skimming of tata 2.5 ton , repair of pressure valve of tata 2.5 ton , repair of re piston head injector nozzle
Tender For job work for the repair of sluice valve size 100 i/d complete./100 mm / at sadat nagar and gujarwas ,repair/disconnection in sanitary water supply connection to avoid mixing of contaminated water complete in all respect as per entire satisfaction of engineer-in-charge /insanitary connection / at sureli ,repair and rectification of w/s leakages found in ac pipe c-15 including excavation, bailing out of water providing and fixing of ci detachable joints c-15 suitable for ac pressure pipe marked with is: 8794 for use with ac pipes complete with 2 no. rubber ring marked with is:5382 & is:10292 and appropriate no. of nuts and bolts marked with is 1363 including carriage in all respect and including cost of ac pressure pipe c-15 as per is: 1592 & 2003 complete in all respect to the satisfaction of the engineer-in-charge/ac 150 mm pipe class-15/ at lukhi ,repair of sluice valve 150 mm complete in all respect./150 mm / at sadat nagar and sureli