Get complete information related to latest Helium Neon Laser Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Helium Neon Laser Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Helium Neon Laser Tenders.
Tender For supply of 29 types of laboratory instruments bid- analytical balance, 05 digits. , bod incubator, capacity 250-300 ltr. , conductivity meter , cod digester with condensers , centrifuge , deep freezer (chest type) , digital portable barometer , double distillation water assembly , fly gas analyzer , filtration assembly with suction pump for , suspended solids , heating mantle , high volume sampler , hot plate with magnetic stirrer , hot air oven , muffle furnace, 800-1000 degree , noise level meter , ph meter , pm 2.5 sampler , refrigerator (2 doors) , respirable dust sampler , specific ion meter for nitrate and fluoride , stack monitoring kit , turbidity meter , total kjheldal nitrogen analyses , uv-visible spectrophotometer real double beam , visible spectrophotometer , weather station for metrological parameters , water bath , thermometer (digital)
Tender For corrigendum : empanelment of agencies for supply of laboratory instruments for various water testing laboratories under jal jeevan mission, assam - ion meter with electrode and accessories for fluoridemeter: ph/ise benchtop meter with electrode stable, universal power adapter, literature, pc cable, meter test certificate electrode: ionplus fluoride and nitrate combination ion selective electrode, 1m cable, waterproof bnc benchtop ion meter (ise) along with fluoride, nitrate #electrode range: -2.000 to 20.000 resolution 0.1, 0.01, 0.001 relative accuracy 0.002 calibration points up to 5 calibration editing yes #mv/ rmv orp range 2500.0 mv resolution 0.1 relative accuracy 0.2 mv or 0.05 % of reading whichever is greater eh orp mode yes ise range 0 to 19999 resolution up to 3 significant digits relative accuracy 0.2 mv or 0.05 % of reading whichever is greater units ppm, m, mg/l, %, ppb, none calibration points up to 5 calibration editing yes calibration features timed end point, linear point to point, non-linear selectable auto-blank, low concentration range stability #temperature range -5 to 105 c, 23 to 221 f resolution 0.1 relative accuracy 0.1 offset calibration 1-point datalogging memory 2000 with time and date stamp log function manual, ready (include auto-read ), timed log edit delete individual points, group of points or all inputs ph electrode bnc, reference pin atc probe 8-pin mini-din #output rs232, usb power ac adapter included universal, 100-240 vac battery power optional 4 aas battery life 800 hrs, fluoride electrode of ion metersame make that of the ion meter, manifold filtration assembly* wide range of pumps and filtration flasks * high quality components * easily exchangeable elements *maintenance-free * low noise * added filters for enhanced pump longevity * filtration base with silicon stopper, cap & aluminium clamp connecting silicon tube technical specification for filtration flask set # high-pressure resistant tube # fiberglass filter membranes (47mm / 0.1 m) # ptfe disc filter #normal liquid filtration * specification for filtration glass set #suction bottle capacity(ml) 1000 ml # filter diameter(mm) 47/50 mm # * specification for filter flask * material: statinless steel 304, capacity: 300 ml (100 ml each) [ unit should consist of 3 flask so that 3 sample can be filtered simultanelously without any issue] # effective filtration area(cm2) = 9.6 cm2, outlet connector(mm) = 8 mm * specification for vaccum flask: #flow rate of the pump(l/min) = 17 l/minultimate vacuum(mbar) = 150 mbar # oil free, maintainance free, built in thermal protection to shut off when over heated., auto cut heater for distill water plant so that when water level decreases the heater is switch off automatically, voltage stabilizer capacity- 3 kva servo stabilizer 5 star rating, heating mantle (single station) should have digital energy regulator with multiple step power regulation automatic spill detection and saftey shutdown in built precision temperature control technial specification: flask capacity 250 ml, working temp range: ambiant + 5 to 420 degree celcius. accuracy: plus minus 1.0 degree celcius, power consumption : 150 w, heating mantle (combined unit) material of construction heating block: made with grade epoxy painted chemical resistant coating, aluminum block with 6 thermo wells for processing 6 different samples at a time. #racks: ss 316 # glassware: teflon coated # temperature range ambient + 10 deg c to 450 deg c # stability of temperature better than 0.5 deg c # controller consist of digital read out of temperature and time with 4 programmable ramps for each method. # number of programmable methods 20 numbers. # heating powers 1000w # heating position minimum 6 position # digestion time range -1 to 999 minutes # the system should have facility of acoustic signal at the end of completion of cycle to notify the operator. # the thermal digestion unit should have high thermal homogeneity # the setup should have small f
Tender For supply of bridge testing kit:- inspection tools consists of: (1).rivet testing hammer 310 mm long & we ight 110 grms (2). magnifying glass 100mm (3). freeman`s pocket steel tape with bubble & belt clip 3 met er long. (4). freeman`s glass fibre tape 30 meter long. (5). precision rail welding straight edge as per is-22 20-1990 with centre knotch & handle 1 meter long. (6). aluminium sounding rod 4 meter long extendable t ype. (7).tilting mirror (convex) (8). inside calliper 10 inch long measurement range: 0 to 10-11/16 in. (9). o utside calliper 10 inch long measurement range: 0 to 10 in (10). prismatic binocular (olympic/nikon)- falco n 10 x 50 or similar 10x zoom (11). shim feeler gauge 4 inch having 10 leaves of 0.05mm to 0.80mm. = 0 2 nos. (12). chisel = 02 nos. (13). safety belt (14). safety helmet as per is:2925 (15). bridge cam welding gauge. size(mm)-0-60, angle-60 ,70,80,90 to take accurate reading of welding of steel welded girders. (16) . heavy duty laser plumb bob with hook string and runner (17). standard wire gauge (18). optical crack m easuring microscope (19). concrete test hammer measuring range 10 to 70 n/mm?, impact energy = 2.207 nm (20). digital coating thickness gauge for ferrous metals, measuring range 0-1250 micron (21). laser ta rgeting distance meter for measuring distances is as bridge heights and hard to reach objects range up to 30 meter. (22). led torch (23). plaster of paris in case (24). red paint with brush and thinner (25). chalk m arker (26). piano wire 30 meters length (27). chipping hammer (28). spirit level with two bubble (29). tds meter digital spec: 0.19-990 ppm (30). chloroscope (chlorine test kit)drinking water testing kit, hardnes s, ph range, chloride, fluoride, nitrate turbidity test, weight of master kit 3kgs. approx) (31). thickness gau ge (32). wire brush (33). good quality protective gloves & eyewear (34). rebound hammer (35). nicely fini shed storing and transportation box and case for keeping above items with all relevant items from srl no 1 to 35. with all relevant items from sr no 1 to 35. [ warranty period: 30 months after the date of delivery ]
Tender For supply installation and commissioning of physics lab at item wise on turnkey basis at govt new model college jhabua 457661 mp india - supply installation of physics lab equipment on turnkey basis, battery charger 2 to 12 volt., ballistic galvanometer with lamp and scale arrangement, spectrometer prism (crown/flint glass), spectrometer 6" 17 ", 30 sec, optical bench with riders double bar, optical bench with riders double bar heavy, inertia table, complete apparatus to verify law of parallel and perpendicular axes for moment of inertia, compund pendulum/bar pendulum, reading telescope, bending of beam apparatus to determine youngs modulus, cantilever to determine youngs modulus, horizontal torisonalpendulamappratus, jaeger apparatlrs to deternrine the surface tension, apparatus to determine the surface tension, apparatus to determine the viscosity of fluid using poiseuiles method, callendor and barnes apparatus to determine the value of mechanical equivalent of heat, measurement of low resistance by carey, potentiometer, lee purpose to determine the hear conductivity of bad conductor of different geometry, apparatus to verify newtons law of cooling, searl apparatus to determine the coefficient of thermal conductivity, sodiurn vapour lamp, transformer for sodium vapour lamp, mercury lamp, transformer of mercury lamp, biprism, complete apparatus to determine the resolving power of a telescope, biquartz are half shade polarimeter, newtons ring apparatus cornplete with travelling microscope power supply and sodium level, electroscope or electrometer, audio fiequency generator, cro dual trace 30 megahertz single tress l0megahertz, i.jse of vibration magnetometer to study a field apparatus, tangent galvanometer, apparatus to study resonance curve for lcr circuit, apparatus for measurement of capacitance and inductance, apparatus to determine the value of plancks constant, complete apparatus to determine e/m using thomson method, complete apparatus to determine e/m by milikons method, apparatus to study the absorption spectra of iodine vapour completes with white light source power supply grating and spectrometer, apparatus to draw bh curve of ferromagnetic material with the help of cro, half wave and full wave rectifier apparatus with built-in power supply, transistor characteristics apparatus with built in power supply and metres, apparatus to study characteristic of tunnel diode, apparatus to study hysteresis curve of transformer core, apparatus to study specific resistance and energy gap of a semiconductor, apparatus to study transistorized regulated power supply, apparatus to study rc coupled amplifier with built-in power supply, zener diode characteristics apparatus with built-in power supply, apparatus to study charging and discharging of a capacitor, complete setup to find the wavelength of sodium light, study of lissajous figure trainer, barton apparatus, digital oscilloscope, adjustable height stands, capillary tube packets of different radii, electrical laboratory kettle with varying voltages, piatinum resistance thermometer, soldering station, desoldering tool, thermocouple apparatus, jfet apparatus to study characteristic curve, hall probe apparatus, plane transmission grating, brewster law apparatus, beam divergence apparatus of heliumneonlaser, diode laser, holographic diffraction grating, michelson interferometer, logic gates apparatus (or, and not, nand, nor, xor), standard tool box, connecting lead wire for electronic apparatus, flywheel