Get complete information related to latest High Pressure Switch Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic High Pressure Switch Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding High Pressure Switch Tenders.
Tender For tender for supply of cctv spare - out-door cat fa 4 pair networking cable onu (wlfi router) gepon onu, ige 1pon port with routing model gopon 10002 1000r-onu or its equivalent full hd led tv 40 inch 01 vga and 02 usb interface power adopter 5v dc ia for media converter input supply- 90 to 265 v ac outplue-5v dc ia power adopter 12 v dc ia for onu input supply-90 to 266 v ac, output-12v dc ia 16 tb external sata hard disc 5 mp wide angle, day-night, ip based full hd bullet camera, housing protection class-ip68 specification: camera type: full hd ip based 5 mp fixed bullet camera communication onvif profile s compliant resolution 5 mp: (min. 1920x1080) compression h.264, h.264, mjpeg, mpeg4 protocol ipv4/v6, tcpap, udp, rtp, rtsp, rtcp, http, https, ssl, icmp, ftp, smtp, dhcp, pppoe, upnp, igmp, snmp v2cc/v3 conjour, dns, ddns, qos, ntp, nfs image: sensor 1/2.8" cmos or better focal length: 28 mm his type: fixed data connectivity wired (ofc & ethernet) ir range upto 100 meter installation: pole mount wall mount housing ip66 ip67 white balance yes iris control auto manual temperature 30°c to 60°c frame rates 1080 p 25/30 fps interface rj45,10/100/1000 mbps ethernet 4 port por switch 10/100/1000mbps 10/100/1000 mbps single mode media converter (b type) for receiving (rx) with rj45 port 10/100/1000 mbps single mode media converter (a type) for transmitting (tx) with r345 port 1500 va/865 w single phase 230 v 6a lise interactive mini-ups with adequate backup tine including automatic voltage regulator (avr) with wide input vahage rangs of 170-260v, battery, data line surge protection, out socket: minimum 4, lcd display displaying lood, status of battery, brief transfer time in ms etc. 2 core 10 sqmm flexible, multistrand, unarmoured pvc sheathed al. cable
Tender For purchase of ece practical equipments - equipments for ece practices:, single output regulated dc variable power supply input voltage: 230v / 50hz ac. output voltage: (0 30) v dc. output current: (0 2) a dc. protection circuit: over voltage, over current, and short-circuit protection. high efficiency: greater than 85%. low ripple and noise: less than 50 mv. digital display., dual output regulated dc variable power supply input voltage: 230v/50 hz ac. output voltage: (0 30) v dc. output current: (0 2) a dc. protection circuit: over voltage, over current, and short-circuit protection. high efficiency: greater than 85%. low ripple and noise: less than 50 mv. digital display, function generator frequency range: 0.1 hz to 5 mhz. display: 4 to 6 digit led display. output waveforms: sine, triangle, square, pulse, ramp. amplitude: 0 20 vpp. rise time: 100 ns. distortion: 1% within specified frequency range. power supply: 230 v ac 10%, 50 60 hz. output amplifier protection: short-circuit and 15 v overload protection. dc offset: 0 to 10 v adjustable. attenuation: 0 to 60 db., dso (digital storage oscilloscope) bandwidth: 50 100 mhz. sampling rate: 1 gs/s. channels: 2 (minimum). power supply: 100 240 v ac, 50 60 hz. automatic measurements: vpp, vavg, vrms, frequency, period, vmax, vmin, rise time, fall time, +width, width, +duty, duty, etc. horizontal scale: 5 ns/div 50 s/div or equivalent. vertical resolution: 8 bits (2 channelssimultaneously). vertical sensitivity: 1 mv/div 10 v/div (at input). waveform math: +, , , , invert, fft, etc. waveform storage: 16 waveforms or equivalent. communication interface: usb host and usb interface. display: 7-inch color display or equivalent. input impedance: 1 m 2% || 20 pf. accessories: 2 passive probes (1x/10x)., digital ic trainer kit with breadboard +5 v dc, 1 a regulated power supply. 12 v dc/ 15 v dc, 200 ma regulated power supply. solderless breadboardwith minimum 840 tie-points,power distribution buses. zif (zero insertion force) ic socketsto accommodate 8 or 16 pinics. logic input and output leds for output monitoring. 16 buffered led outputs. 16 debounced switch inputs. variable clock generator: 0.5 hz to 50 hz. single pulse output: 100 ms (buffered, positive and negative outputs). one seven-segment display with 4 bcd inputs. built-in logic switches. manual clock: debounced push-button (one pulse per press)., fpga trainer kit must use industry-standard mid-range fpga device usb-jtag programmable, compatible with vivado ise (webpack). power supply: 5 v dc through usb or external adapter. on-board peripherals: leds, switches, push buttons, 7-segment display,clock source, gpio / pmod expansion ports, uart, vga / hdmi, usbuart bridge, usb cable. user manual.
Tender For supply of single phase 2 hp submersible pump starter, having contactor 02 pole and thermal ol relay (make: havells, bch, lsis, l&t) with start and run capacitor, panel meter indicator and on off push button, panel should be automatic and no need to push extra push button to change capacitor, provision require for connecting externally minilec make water level controller or eapl/ l&t time switch to make it fully automatic. make: lsis, bch, l&t, kirloskar or equivalent [ warranty period: 30 months after the date of delivery ] ]
Tender For purchase of non-consumables for ece department - purchase, dual output regulated dc variable power supply input voltage: 230v/50 hz ac. output voltage: (0 30)v dc. output current: (0 2)a dc. protection circuit: over voltage, over current, and short-circuit protection. high efficiency: greater than 85%. low ripple and noise: less than 50 mv. digital display., function generator frequency range: 0.1 hz to 5 mhz. display: 4 to 6 digit led display. output waveforms: sine, triangle, square, pulse, ramp. amplitude: 0 20 vpp. rise time: 100 ns. distortion: 1% within specified frequency range. power supply: 230 v ac 10%, 50 60 hz. output amplifier protection: short-circuit and 15 v overload protection. dc offset: 0 to 10 v adjustable. attenuation: 0 to 60 db., dso (digital storage oscilloscope) bandwidth: 50 100 mhz. sampling rate: 1 gs/s. channels: 2 (minimum). power supply: 100 240 v ac, 50 60 hz. automatic measurements: vpp, vavg, vrms, frequency, period, vmax, vmin, rise time, fall time, +width, width, +duty, duty, etc. horizontal scale: 5 ns/div 50 s/div or equivalent. vertical resolution: 8 bits (2 channelssimultaneously). vertical sensitivity: 1 mv/div 10 v/div (at input). waveform math: +, , , , invert, fft, etc. waveform storage: 16 waveforms or equivalent. communication interface: usb host and usb interface. display: 7-inch color display or equivalent. input impedance: 1 m 2% || 20 pf. accessories: 2 passive probes (1x/10x)., digital ic trainer kit with breadboard +5 v dc, 1 a regulated power supply. 12 v dc / 15 v dc, 200 ma regulated power supply. solderless breadboard with minimum 840 tie points,power distribution buses. zif (zero insertion force) ic sockets to accommodate 8 or 16 pin ics. logic input and output leds for output monitoring. 16 buffered led outputs. 16 debounced switch inputs. variable clock generator: 0.5 hz to 50 hz. single pulse output: 100 ms (buffered, positive and negative outputs). one seven-segment display with 4 bcd inputs. built-in logic switches. manual clock: debounced push-button (one pulse per press)., lvdt trainer kit ac mains power supply: 230 v 10%, 50 hz. fixed regulated dc power supply: +5 v, 12 v / 500 ma. transducer: lvdt. lvdt displacement: 20 mm (40 mm total). displacement scale: linear 20 mm. displacement display: red color 3 digit led display. excitation frequency: 4 khz. excitation voltage: ac variable excitation voltage up to 5 v., strain guage trainer kit ac mains power supply: 230 v 10%, 50 hz metal foil strain gauge mounted on beam/cantilever. strain measurement under applied load. wheatstone bridge arrangement. signal conditioning and amplification circuit. instrumentation amplifiers with 3 digit display for strain / output voltage. zero and gain adjustment controls. provision for applying calibrated loads. table-top trainer with labelled panel. test points for signal measurement. built-in dc power supplies and wooden closed cabinet. supplied with patch cords and user manual.
Tender For corrigendum : supply of set of spares for sidwal make roof mounted cab ac for 3 phase locomotive.set consists of 07 items as given below: roof mounted cab ac specification rdso/2007/el/spec/0055 rev 2. 1) cooling coil-evaporator partno:sr-0817-2 nos 2.) condenser coil- part no:sr-0815-2 nos 3.) filter drier- part no:sr-4360-20 nos 4.) highpressure cut-out- part no : sr-4361-4 nos 5.) low pressure cut-out- part no:sr-4362-6 nos 6.) highpressureswitch- part no:sr-4363-4 nos 7) .mcb 16amp tp,2.0 pole- part no:sr-4365-5 nos. make: sidwal only. [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For supply of set of spares for sidwal make roof mounted cab ac for 3 phase locomotive.set consists of 07 items as given below: roof mounted cab ac specification rdso/2007/el/spec/0055 rev 2. 1) cooling coil-evaporator partno:sr-0817-2 nos 2.) condenser coil- part no:sr-0815-2 nos 3.) filter drier- part no:sr-4360-20 nos 4.) highpressure cut-out- part no : sr-4361-4 nos 5.) low pressure cut-out- part no:sr-4362-6 nos 6.) highpressureswitch- part no:sr-4363-4 nos 7) .mcb 16amp tp,2.0 pole- part no:sr-4365-5 nos. make: sidwal only. [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]