Get complete information related to latest High Pressure Switch Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic High Pressure Switch Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding High Pressure Switch Tenders.
Tender For tender for supply of ac compressor with standard accessories , compressor motor for accel smc 6-65 , steel base frame for accel smc 6-65 compressor , accel make shell & tube condenser , insulation for suction line for smc 6-65 compressor , accel make ahu , refrigration controls for accel smc 6-65 compressor , refrigerant pipes , valves & fittings for smc 6-65 compressor , starter & control panel for hold compressor , shock mounts for accel smc 6-65 compressor (1set is 32nos) , highpressure-low pressure and oil pressure gauges , board for mounting gauges and cutouts and pressure gauges , highpressureswitch/cutout , low pressureswitch/cutout , oil pressureswitch/cutout , type testing (if any)
Tender For tender for supply of vrf unit spares - vrf unit outdoor one way valve 16.0x16.0-160 , vrf unit outdoor exv body ukv-32d61 , vrf unit outdoor exv coil ukv- a519 l 1300 , vrf unit outdoor elec exp valve body ukv4.0d r4 10a , vrf unit outdoor highpressureswitch h2ops d 4.5 or 3.5 , vrf unit outdoorunloading vlve body fdf2a zb 6.35 r410a , vrf unit outdoor unloading valve coil fdf2a l 1500 , vrf unit outdoor electroma gnetic valve fdf6a , vrf unit outdoor electroma gnetic valve sol fdf2a l 1000 , vrf unit outdoor 4-way rev valve assy shf- h35672-003 , vrf unit ahu electric control box module , vrf unit ahu electric reactor dk-2mh-40a l 440 , vrf unit outdoor double fan module qd-12121f4 50w-1 sy , vrf unit outdoor single fan module qd-12121f7 50w-1 sy , vrf unit outdoor terminal block 4 bite 600v , 35mm2 , vrf unit outdoor main pcb dlw- bp-3f5 x7 - e2 sy , vrf unit outdoor alt current contactor gc3-18 or 01 kkg , vrf unit outdoor transfome r tdb-16- b2b , vrf unit outdoor hp sensor 35cp02-06 l 1300 , vrf unit outdoor lp sensor 35cp02-05 l 1300 , vrf unit outdoor temp sen asy 5 15k or 20k or 50k395 asy 5 15k or 20k or 50k395 , vrf unit outdoor temp sensor assy 1 50k3950 xh2 1.4m , vrf unit outdoor temp sensor assy 2 20k or 50k 3950xh4 1.1m , vrf unit outdoor radiator ipm module assembly qd-3330 , vrf unit outdoor radiator ip m mod assy vxv-h400-450- sr1mv , vrf unit outdoor dc motor dmsb-450w-8p , vrf unit outdoor dc motor dmsb-750w , vrf unit outdoor axial fan 600x178 , vrf unit outdoor axial fan 700x206.6 , vrf unit outdoor dc inverer compresso r aa55phdg- d1y2 , vrf unit outdoor dc inv scroll compresso r- dc80phdg- d1y2 , vrf unit outdoor , four-way valve shf-h35792-007 l 2000 , vrf unit outdoor , ac1644200 1000024 or filter 6x8-50 , ahu unit ac1644200 1000013 or filter 9.52x9.5 , vrf unit outdoor , ac11222541000077 , main control board , vrf unit outdoor , ac11222544000015 , extension board , vrf unit outdoor , ac16422005000009 , transformer , ahu unit , ac16426093000013 , electronic expansion valve coil , ahu unit , ac16430007000257 , temperature sensor 15k3950 xh2 white 10m plastic package , ahu unit , ac16430007000256 , temperature sensor 20k3950 xh2 blue 10m copper head , vrf unit outdoor , ac16325034000032 , expansion valve assembly double valve , vrf unit outdoor , ac11102020001268 , dc inv scroll compr gmcc savc070d44ulkd , vrf unit outdoor , ac11201008000812 , hp sensor cgq-yl-nsk-bh046ju773l2500l01 , vrf unit outdoor , ac17400516000928 , hp sensor cgq-yl-nsk-bh046ju773l2500l01 , vrf unit outdoor , ac17400516000928 , hp switch yk-4.2 or 3.2-c-1500-vhr , vrf unit outdoor , ac11201008000832 , lp sensor cgq-yl-nsk-bh020j-u832-l1800-l-01 , vrf unit outdoor , ac17127000011164 , filter board assy , vrf unit outdoor , ac17127000011136 , compressor + fan module board 16-20hp , vrf unit outdoor , ac17400306001763 , reactor r4015 al -1 , temp. display , ac11201007007123 , temperature sensor , temp. display , ac11201007000098 , pipe temperature sensor , ac11201007005423 , pipe temperature sensor , temp. display , ac11201007000328 , pipe temperature sensor , ahu unit , ac11201007000252 , pipe temperature sensor , ahu unit , ac11201007003438 , room temperature sensor , outdoor , ac11201007003438 , outdoor main control board assembly -v8x , ahu unit , ac17227000005241 , power module assembly , ahu unit , ac11002015015348 , brushless dc motor zksn-920-10-2l , outdoor , ac17402001001259 , compressor electric heater djrd-520a-1400-50w-vhr , outdoor , ac12100105001202 , axial fan zl- 750x210x20-4 , ac15500213002269 , eev suite eev45t500p-2000xhp5 w , ac15500204000130 , lp valve , ac15500213000914 , eev suite eev24t500p-2000xhp5 g , outdoor , ac15500203000968 , one way valve , outdoor , ac15500216000528 , four-way valve suit , outdoor , ac11102020001267 , dc inv scroll comp gmcc sav060d11ulkd , outdoor , ac17127000011162 , filter board assy , outdoor , ac17127000011139 , compressor + fan module board 22-28hp , outdoor , ac11201007002461
Tender For estimate for procurement of material required for maintenance of existing ccms boxes for maintenance in all divisions of allwyn colony circle 51 of kukatpally zone cmc - supply of 1 phase nature switch -smart timer based timer box make, kakatiya. , supply of 50-63a sp mcb 1 no 10 ka, c/d curve isi mark. makes : legrand-dx3 / schneider-acti9 / siemens / lk exora / bch / havells stadx sl.no. 638 c, elec. 2.14.1, ssr 2025-26 , supply of 6-32a sp mcb 10 ka, c/d curve isi mark. makes : legrand-dx3 / schneider-acti9 / siemens / lk exora / bch / havells stadx sl.no. 636 a, elec. 2.14.1, ssr 2025-26. , supply of power contactors with 32 a 4 pole, front on/off indication, alpha-numeric terminal markings with dc ratings available & click fit type construction. as per the market rate. make: l &t, hpl, schneider , supply of waterproof 220 v auto day/night on/off photocell, ldr sensor switch for lighting, 300 vac protection. as per the market rate. make: amicismart, murphy, along with all accessories , supply of waterproof 220 v nature switch -smart timer day/night on/off ( technical specifications: 120-440 vac, 50-60 hz, 10 amps output, >5000 cycles, <1 watt consumption, customizable on/off illuminace. ip 65 rating, 130 x 130 x 65 mm (46mm front) . as per the market rate. make, kakatiya.
Tender For supply of set of spares for sidwal make roof mounted cab ac for 3 phase locomotive.set consists of 07 items as given below: roof mounted cab ac specification rdso/2007/el/spec/0055 rev 2. 1) cooling coil-evaporator partno:sr-0817-2 nos 2.) condenser coil- part no:sr-0815-2 nos 3.) filter drier- part no:sr-4360-20 nos 4.) highpressure cut-out- part no : sr-4361-4 nos 5.) low pressure cut-out- part no:sr-4362-6 nos 6.) highpressureswitch- part no:sr-4363-4 nos 7) .mcb 16amp tp,2.0 pole- part no:sr-4365-5 nos. make: sidwal only. [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For tender for supply of fixing self regulating heat tape cable insulation and accessories in ppr pipe - providing and fixing self regulating heat tape resistance heating cable suitable to protect freezing of water in pipelines having rated output of 35 w per meter at 220 v ac supply the heating cable shall have capabibility to automatically adjust its heat output based on surrounding temperature conditions to prevent freezing and overheating the cable should be suitable for continuous operation in outdoor in adverse climatic conditions flexible for installation around pipelines joints and valves and compatible with temperature controller systems , providing m20 3 pin connector suitable for making secure electrical joints between self regulating heat cable terminals designed for reliable power and signal continuity the connector should be operable for operation at rated 220 v ac supply and compatible with heating cables of specified capacity must l ensure safe and firm termination with robust insulation to prevent moisture ingress short circuits and electrical leakage the connector shall be made up from high-quality weather resistant materials suitable for continuous outdoor operation under adverse environmental conditions it should be ease in installation with a compact and durable design for use in pipeline joints terminations and interconnections the connector should be compatible with temperature control systems and associated accessories ensuring long term performance safety and protection against overheating corrosion and mechanical stress , providing temperature differential controller with auto and manual operation housed in a robust ip65 rated enclosure suitable for controlling heat tracing systems to prevent freezing of water in pipelines and utilities the controller should be capable to automatically switch the heat tape on off based on preset temperature differentials ensuring optimal performance and energy efficiency the controller should have in built safety features such as overrun protection and burn out protection to safeguard the heating cable and associated equipment from damage the enclosure shall be weatherproof and suitable for outdoor installation offering protection against dust and water ingress and ensuring reliable long term operation under harsh environmental conditions , providing pt100 temperature sensors with 10 metre cable suitable for accurate temperature measurement and control in heat tracing and pipeline monitoring applications the sensors should be made up of platinum resistance type pt100 ensuring high precision stability and reliability over a wide temperature range the wire with sensor should have high quality insulation suitable for reliable signal transmission and compatible with temperature controllers and monitoring systems the cable shall be durable flexible and suitable for installation in outdoor under extreame weather conditions in high altitude area , providing 3 core 1.5 sq mm pvc insulated and pvc round sheathed multicore flexible cable comprising bright annealed bare copper conductors suitable for heavy duty industrial applications rated for voltage grade up to 1100 volts the cable shall confirm to requirements of is 694 2010 the conductors shall be made of high-conductivity annealed copper ensuring efficient current carrying capacity and minimal losses each core shall be uniformly insulated with high-quality pvc compound and the overall cable shall be protected with a durable pvc outer sheath providing resistance against moisture abrasion and mechanical stresses the cable shall be flexible in nature allowing ease of installation in confined and complex routing conditions it should be suitable for continuous operation in indoor and outdoor adverse environments offering reliable performance electrical safety and long service life
Tender For supply of abc cable straight jointing kit of size 95 sqmm single core heat shrink type. , abc cable straight jointing kit of size 120 sqmm single core heat shrink type , nature switch 25kw 3 phase , wall fan for crew manning cft and ambulance , all in one 60 watt solar light , flame proof led light fitting four feet 1x20 watt 4 feet.