Get complete information related to latest High Voltage Unit Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic High Voltage Unit Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding High Voltage Unit Tenders.
Tender For procurement of materials for repair of various components used in the fixing of light poles installed across of the failure different wards within municipal area - 61.13 p/l of double wall corrugated hdpe pipe confirming to is 16205 p-24, stiffness class 750 n, externally corrugated and having smooth surface inside with hdpe coupler, elbow, tee at required depth below the ground for laying cable of following nominal outer dia. mfr test report from nabl accrediated is to be submitted. (excavation of earth & back filling with compaction is to be paid extra) all as per pre approved by engineer in-charge.. for additional technical parameters of products/ work, refer annexure "a" attached with this bsr 50mm dia. , providing & laying p.v.c. / xlpe insulated & p.v.c. sheathed unarmoured copper cable confirming to is:1554 p-i / is:7098 p -i of 1.1 kv with electrolytic grade copper made of copper rods confirming to is 613-1964, of purity >99.7%, inner/outer sheath confirming to is:5831 in existing rcc/hume/stoneware / pvc pipe/open duct/cable trench/cable tray (with cable tie) including testing etc. as required of following size. oem must have it's own in house nabl accrediated laboratory for testing procedure as per is:10810 for additional technical parameters of product / work refer annexure 'a' attached with this bsr 3 core , supplying and making one end termination with nickel plated heavy duty brass single compression gland (as per is 12943-1990)) sibg type consisting of check nut, gland body, metal washer(3 nos.), outer seal rubber ring, compression nut, heavy duty aluminium lugs (as per is 8309-1993) duly crimped with crimping tool, pvc tape as per is 8337-1976 of following size of pvc insulated & pvc sheathed/ xlpe aluminium conductor cable of 1100 volt grade as required.all as per pre approved by engineer in-charge. for additional technical parameters of products/work, refer annexure "a" attached with this bsr 4 x 10.0 sq.mm pvc tape roll , supply and fixing of following lt supporting accessories with nut bolt & clamps made out as per standard discom's specifications with two coats of red oxide and two coats of aluminium paint etc. as required. all as per pre approved by engineer in-charge.for additional technical parameters of product / work refer annexure "a' attached with this bsr type a lt connector for aerial bunched cable each 73.00
Tender For supply of earthing cable 95 sq mm, 4kv, black colour, 500mm length both side crimping lugs withwire braided mesh, spec, no. elrs/spec/elc/0019 (rec-4), icf drg. no. tm/mc/890-7-0-014 alt-k for vande bharat and memu accepted description : as above with yellow green colour cable 95 sq. mm as per rdso spec elrs/spec/wlc/0019 (rec-4) with ss mesh 3 kv crimping lug: 95 sq, mm with stud hole m10. [ warranty period: 30 months after the date of delivery ] ]
Tender For 06/2026-27/ - deposit work(running work) in sub division masauli under edd ramnagar. - safe loading carriage including unloading and proper stacking of following materials from central store barabanki / je store to site of work., pcc pole /stp pole 8.5/11/13 mtr long, 11kv pin insulator ., 11kv disc insulator ., 11kv x-arm, ms earthing rod, transformer 25/63/100 kva, abc cable 3x50/95 sq. mm., abc cable 1x25+1x16 sq. mm., 11 kv xlpe cable 3x70++3x120+3x185 sqmm, acsr weasal conductor, lt d.b. box, 11 kv ct/pt unit, 11 kv metering cubical/pilfer, stay set complete, other line material, dragging of pole from je dump store to site, erection of stay set of 16x1800 mm rod duly painted with red oxide,anchor plate, and stay insulate etc., stringing and sagging of 11 kv line with acsr weasal conductor including nuzzling binding and jumpering (weasal conductor will be provided by the department), pipe earthing ( boring type 40 feet), installation of mounting of following capacity of transformer including its connection between 11 kv and lt line mounting provinding crimping type aluminium lugs of required size.( all the material except transformer will be arranged by the contractor), mounting of 25/63/100 kva tranformer, installation of fixing 11 kv ct/pt with required meterial., installation of fixing 11 kv pilfer unit with required meterial., errection of substation type double pole with pcc /stp 8.5/11/13 pole mtr. long . including mounting of top channal dropper channel, base angle with clamps with nut & bolt, fitting of 33/11 kv pin & pin insulator., errection of single pcc /st pole for stringing, jumpharing and sagging of conductor 1/6 of total length of poles, stringing and sagging of lt 1x16 abc cable (lt abc cable will be provided by the department), stringing and sagging of lt 3x50 /95abc cable (lt abc cable will be provided by the department), installation of d.b. box, earthing of pole with ms earthing., provinding & fixing of various type materials. all materials shall be supplied by the contractor., nut & bolt, pg clamp, clamp for top/ dropper and t-off2/stay/lt etc., gi pipe 3"&4 dia, l t insulator, looping and choopping of tree branches in laying on the route of line., laying of 11kv xlpe cable 3x70, 120,185 sq. by mm manually, concreating and pilinthing of st& pcc pole 18x24 cm., fabricate with hole suitable size in steel items, receive from central store light as top channel/dropper channel sub station base angle etc., looping of cable and mounting of pole., gaurding of 11 kv line, dismentaling of 11 kv line & poll, other line work
Tender For deposit work(running work) in sub division ramnagar under edd ramnagar. - safe loading carriage including unloading and proper stacking of following materials from central store barabanki / je store to site of work., pcc pole /stp pole 8.5/11/13 mtr long, 11kv pin insulator ., 11kv disc insulator ., 11kv x-arm, ms earthing rod, transformer 25/63/100 kva, abc cable 3x50/95 sq. mm., abc cable 1x25+1x16 sq. mm., 11 kv xlpe cable 3x70++3x120+3x185 sqmm, acsr weasal conductor, lt d.b. box, 11 kv ct/pt unit, 11 kv metering cubical/pilfer, stay set complete, other line material, dragging of pole from je dump store to site, erection of stay set of 16x1800 mm rod duly painted with red oxide,anchor plate, and stay insulate etc., stringing and sagging of 11 kv line with acsr weasal conductor including nuzzling binding and jumpering (weasal conductor will be provided by the department), pipe earthing ( boring type 40 feet), installation of mounting of following capacity of transformer including its connection between 11 kv and lt line mounting provinding crimping type aluminium lugs of required size.( all the material except transformer will be arranged by the contractor), mounting of 25/63/100 kva tranformer, installation of fixing 11 kv ct/pt with required meterial., installation of fixing 11 kv pilfer unit with required meterial., errection of substation type double pole with pcc /stp 8.5/11/13 pole mtr. long . including mounting of top channal dropper channel, base angle with clamps with nut & bolt, fitting of 33/11 kv pin & pin insulator., errection of single pcc /st pole for stringing, jumpharing and sagging of conductor 1/6 of total length of poles, stringing and sagging of lt 1x16 abc cable (lt abc cable will be provided by the department), stringing and sagging of lt 3x50 /95abc cable (lt abc cable will be provided by the department), installation of d.b. box, earthing of pole with ms earthing., provinding & fixing of various type materials. all materials shall be supplied by the contractor., nut & bolt, pg clamp, clamp for top/ dropper and t-off2/stay/lt etc., gi pipe 3"&4 dia, l t insulator, looping and choopping of tree branches in laying on the route of line., laying of 11kv xlpe cable 3x70, 120,185 sq. by mm manually, concreating and pilinthing of st& pcc pole 18x24 cm., fabricate with hole suitable size in steel items, receive from central store light as top channel/dropper channel sub station base angle etc., looping of cable and mounting of pole., gaurding of 11 kv line, dismentaling of 11 kv line & poll, other line work
Tender For supply of aluminium tubular terminal 25 sq. mm. 1700010450 , mcb 16a sp miniature circuit breaker 1700010199 , mcb 32a 10ka 2p miniature circuit breaker 1700006730 , combined flush type polycarbonate switch 1700003305 , 35 sq mm crimping type copper cable lugs 1700002618 , mcb 16 amp mcb single pole 415 v 50 hz 1700010471 , plug top polycarbonate flush type 1700002984 , 185 sqmm crimping type al cable lugs1700002563 , capacitor 2.5 mfd 400 vfor ceiling fan 1700009563 , flush type polycarbonate material switch 15 a 1700003454 , 240 sq. mm.crimping type electrolytic aluminium lug 1700001683 , electric call bell ding dong door bell 1700010277 , piano type switch flush type polycarbonate switch 5 a 1700006731 , plug top polycarbonate flush type 1700002986 , heavy duty ferrule for 6600 v connections 185 sq. mm.1700002003 , lt auto cable 6 sq mm automotive 1700003912 , lug cu 35 sqmm 1700002015 , flush type polycarbonate bell push switch 5 a 1700000059 , aluminium tubular terminal 120 sq. mm. 1700010448 , aluminium tubular terminal 50 sq. mm. 1700010449 , lamp holder pendent type holder 1700002254 , 16 sq mm crimping type aluminium cable lugs 1700002578 , 16 sq mm crimping type aluminium cable lugs 1700010447 , socket flush type polycarbonate 1700003314 , lamp holder pendent type holder 1700002255 , switch polycarbonate flush type 1700003405 , automotive electrical cable 1700007856 ) /bid number : gem/2026/b/7564682 * /dated: 23-05-2026 & & / bid document 1 / 32
Tender For corrigendum : supply of traction transformer for hs-spic with required number of secondary traction windings along with protection equipment, safety varrangement and ht cablewith protection shield including termination crimping lugs, cable markers with heat shrinkable sleeves for power and control cables, mating connectors, equipment mounting and earthing hardware and accessories including auxiliary machines such as oil pump, oil cooling blowers as per clause 4.3 of rdso specification no. rdso/pe/spec/emu/0196-2019 (rev.0) along with mounting hardware (one set per hs-spic)., as per drawing: as per clause 4.3 of rdso specification no. rdso/pe/spec/emu/0196-2019 (rev.0), packing instruction: suitably covered with biodegradable transparent polythene and packed in wooden box.the material used for product packaging shall be eco-friendly .each packing shall be stenciled/labeled handle with care, consignee name, order no,pl's no , description ofitem, batch no, drg/spec no, qty,firm's name, &date of despatch etc. note- 1) firms have option to provide qr code. for linkage of po, the cardboard box shall carry a qr code having details as listed below: a)nameof the manufacturer b)purchaseorder number c)purchaseorder date d)uniqueserial number (or lot number for bulk items) of the manufacturer or e)dateofmanufacture f)deliverychallan no. g)deliverychallan date 2.the qr code shall be as per iso/iec 18004 model2 and the data shall be available as xml using the tags detailed above. [ warranty period: 36 months after the date of delivery ]
Tender For corrigendum : procurement of electrical material for maintenance and repairing of 66/11kv and 220/66kv substation of dnhddpcl. - supplying bolted connections (bs type) hrc fuse link capable to withstand 80ka, 415 v confirms to i.s. 13703 for following current capacity. make ftc/l&t/havells(i) hrc fuse link -2 amp, (ii) hrc fuse link -4 amp, (iii) hrc fuse link -6 amp, (iv) hrc fuse link -10 amp, (v) hrc fuse link -20 amp, supplying bolted connections (bs type) hrc fuse base suitable for 2 amp. to 20 amp. 80 ka, 415 v hrc bolted fuse link. as per is/iec 60269 part-ii, supplying of led indoor fittings with leds of wattage 0.2 watt to 0.5 watt assembled on single mcpcb, with housing used as a heat sink shall be made of thick sheet steel conforming to is: 513, volt 160v to 270v, (a) tube light with integral driver 20 watts, 4 feet make: philips / bajaj / crompton, supplying of approved make single phase industrial exhaust fan suitable for medium duty ring mounted low noise operation suitable for medium duty having following [a] 305 mm dia 900 rpm make: bajaj/hevells/ crompton /almonard, supplying of approved make ceiling fan with double ball bearing isi mark with condenser a.c. 23ov. 50 c/s.1200 mm. sweepmake: bajaj/hevells/crompton /usha/orient , supplying of approved make pedestal fan a.c. 230v. 50 cy/s. 400 mm sweep oscillating, type and adjustable, height complete with guard regulator, & standard lead flexible wires and plug top. make: bajaj/hevells/ crompton /usha/orient, supply of tnc switch with lock for 66/11 kv panel, supply of petroleum jelly for sub-station equipments protection (1 kg pack), indicating lamp led type, mount hole-22 mm, 110 v dc with back panel lock nut fitting.red- 100 nosyellow-100 nosgreen-100 nosblue-100 noswhite-100 nos, providing crimping type cable terminals (lugs) conforming to is of following types and sizes. (aluminium tubular terminals long barrel)) .240 sq. mm, providing crimping type cable terminals (lugs) conforming to is of following types and sizes. (aluminium tubular terminals long barrel)) .300 sq. mm, supply of telescopic earth / discharge rod up to and included 66 kv, 72.5 kv tested manufacture in fully automatic pultrusion plant having strong electrical & mechanical strength. as per specification.a. total section 4 sectionb. assembled height 18 feetmake :- biemco or equivalent, supply of shroud for 11 kv panel, 12 kv , jyoti make (as per approved sample), supply of jaw contact female, 11 kv, 1600 amp. jyoti make( as per approved sample), supply of tripping coil, 110 v dc for 11 kv panel (suitable for abb & jyoti make panel), supply of closing coil, 110 v dc for 11 kv panel (suitable for abb & jyoti make panel), supply of natural rubber latex seamless hand gloves for electrical purpose tested as per is 4770-1991 having test potential of 33000 volts and maximum working potential 11000 volts of size 380 mm crystal brand., supply of rechargeable torch with led bulb make: eveready/hevells/ wipro
Tender For corrigendum : laying of 1100v, 3.5 core 300 sq. mm. aluminium cable in 2 runs of cable route lenth 150 mtrs , shifting erection & installation of acb panel including civil/ fabrication works , 1100v, 3.5 core, 300 sq. mm. aluminium cable terminations including lugs crimping and installation of
Tender For ghrssidc/e-t/2026-27/646 - electrical fabrication - a, la cross arm clamp for 7.5 mt rcc pole (gal v) - cee/e/523, sa cross arm clamp for 7.5 mt rcc pole (gal v) - gec/e/523, la cross arm clamp for 9 mt rcc pole (gal v) - gec/e/524, sa cross arm clamp for 9 mt rcc pole (gal v) - gec/e/524, la cross arm clamp for 105 lbs/yd rail pole (gal) - gec/e/723, sa cross arm clamp for 105 lbs/yd rail pole (gal) - gec/e/723, la cross arm clamp for 60 lbs/yd rail pole (gal) - cee/e/486, sa cross arm clamp for 60 lbs/yd rail pole (gal) - cee/e/486, la cross arm clamp for 90 lbs/yd rail pole (gal) - cee/e/515, sa cross arm clamp for 90 lbs/yd rail pole (gal) - cee/e/515, la stay clamp for 60 lbs/yd rail pole (gal) - cee/e/469, sa stay clamp for 60 lbs/yd rail pole (gal) - cee e 469, la stay clamp for 90 lbs/yd rail pole (gal) - cee/e/508, sa stay clamp for 90 lbs/yd rail pole (gal) - cee/e/508, la stay clamp for 7.5 mtrs rcc pole galvanised - cee e 523, sa stay clamp for 7.5 mtrs rcc pole galvanised - cee e 523, la stay clamp for 105 lbs/yd rail pole (gal) - cee e 723, sa stay clamp for 105 lbs/yd rail pole (gal) - cee e 723, la stay clamp for 9 mtrs rcc pole (gal v) - cee e 524, sa stay clamp for 9 mtrs rcc pole (gal v) - cee e 524, 11 kv v shaped cross arm (gal v) - cee e 408, 33 kv v shaped cross arm (gal v) - cee e 408, b type modified distribution box - cee e 386, a type street light meter box with clamps - cee e 386, stay set for 11 kv lt line - cee e 500, stay set for 33 kv line - cee e 500, turn buckle& eye bolt for 33 kv line - cee e 513, turn buckle& eye bolt for 11 kv line -cee e 466, cast iron packing piece 90 lb for rail pole - cee e 514, top insulators fitting for rcc pole - cee e 506, 4 pin angle type cross arm - cee e 702, 4 pin channel type cross arm - cee e703, 2 pin angle type cross arm - cee e704, 2 pin channel type cross arm - cee e 705, earthing pipe - cee e 467, sa cross arm clamp for ht/lt line on 11 mt rcc pole made of 50 x 10 flat (g) - cee e 711, la cross arm clamp for ht/lt line on 11 mt rcc pole made of 50 x 10 flat (g) - cee e 711, sa stay clamp for ht/lt line on 11 mt rcc pole made of 50 x 10 flat (g) - cee e 711, la stay clamp for ht/lt line on 11 mt rcc pole made of 50 x 10 flat (g) - cee e 711, sa bottom clamps for fixing street light fixtures for 7.5/9mtrs rcc pole galvanised 25 mm pipe - cee e 12, sa top bottom clamps for fixing street light fixtures for 7.5 mts rcc pole galvanised 25 mm pipe - cee e 12, la top clamps for fixing street light fixtures for 7.5/9 mts rcc pole (gal v) 40 mm pipe - cee e 612a, sa top clamps for fixing street light fixtures for 7.5 rcc pole - cee e 612a, gi nut and bolts in various sizes electro galvanised, gi pins for lt pin insulator, gi pins for 11kv pin insulator, gi pins for 33kv pin insulator, gi bent pipe of nominal base 25 mm, 1 mts long for tube light fixture - cee/e 618, gi bent pipe of nominal base 25 mm, 1.5 mts long for hpsv lamps - cee/e 593a, b type modified distribution box with mccb and kit kat fuses as per cees specifications / drawings, metal parts for shackle insulators as per cees specifications, gi bent pipe of nominal base bar 40mm x 3 mts long (medium class) the pipe shaft should conform to is : 1239 (part i) 1973 as amended upto date - ee/ii/21/2009, hot dip galvanised earthing strips of size 30x160x5mm, hot dip galvanised earthing strips of size 100 x 360 x 3mm, g.i bent pipe nominal bore 40 mm ce/e xi for hpsv lamps - cee/e 593a, metal parts for disc insulator as per department 4 bolted. as per department specification & drawing - 60/4/va/cee/tech/2019-20/1282, metal parts for disc insulator 3 bolted - 60/4/va/cee/tech/2019-20/1282, kit kat fuse 100 amps, kit kat fuse 200 amps, kit kat fuses 300 amps, kit kat fuse 400 amps, tinned copper fuse wire of various sizes, aluminium crimping lugs 25 sq.mm, aluminium crimping lugs 35 sq.mm, aluminium crimping lugs 50 sq.mm, aluminium crimping lugs 70 sq.mm, aluminium crimping lugs 95 sq.mm, aluminiu