Get complete information related to latest Horn Gap Fuse Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Horn Gap Fuse Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Horn Gap Fuse Tenders.
Tender For supply of miscellaneous electric items - steel tubular 9 mtr. long pole (st-410 sp33) , acsr weasel conductor 6/1/2.59 mm , 11 kv go, ab switch 3-phase, 3-pole, 200 amp vertical type with rod heavy duty , back clamp for 9 mtr. pole with fitting , 11 kv horngapfuse set (hg set) 3-phase 400 amp polymer type heavy duty , la set station type (gapless surge arrestor, 9kv, 10 ka, la with polymer housing station type heavy duty) , xlpe pvc cable single core 300 mm sqr. (300 sq mm cable 1.1 kv grade, pvc insulated standard conductor frls type) , 11 kv polymeric pin insulator 12 kv, 5 kn, lighting impulse 75 kv positive and 80 kv negative, creepage distance 320 mm , insulator disk 11 kv (11kv polymeric composite discs insulator with pin and gl fittings, 12 kv, mainfalling load 45 kn, lighting impulse 75 kv positive and 80 kv negative, creepage distance 320 mm) , channel 100.00 mm x 50.00 mm x 5.00 mm (10 feet long) , nut bolt full thread with washer 4"/6" heavy duty , wedge connection / pg clamps , danger plate and clamps , g.i. bracket wire for anti climbing , 3 phase 4 wire trivector meter with ct/pt unit , aluminium thimble 185 mm , lv distribution box for 400 kva dtr with mccb for incomer & sfu's for outgoing circuits , stay set (gi rod with clamp) - galvanised stay set with 50x8mm stay clamp, gav. insulator (02 nos.) anchor plate (200x200x6mm) nut-bolt 2 nos. turn-buckles, 1.8 m long 16 mm diameter solid g5 stay rod & 7/3. 15 mm dia gi standard wire complete , g.i. guy rod complete with clamp and insulator , anti climbing device with clamp , guy / stay wire 7/14, galvanized steel, typically hot-dip zinc-coated for corrosion resistance , giv cross-arm with top bracket and gi channel-arm including clamp (gi v cross arm with top bracket including clamp and gl channel x-arm including clamps and braces) , channel 75 x 75 x 6mm (10 feet long) , g.i. earthing wire 8/10 mm
Tender For supply, installation, testing and commissioning of mcb/mccb testing kit with dual mode outputs i.e mode no.- 01) -0.01 to 100 amps ac for mcbs mode no.- 02) 100a to 2000a ac for mccbs. make :- r k industries ,yamini, starlight, megger, fluke ,eaton. features 1) main isolated ac injection currents, 2). twoin one test kit to test miniature circuit breaker (mcb) bimetal o/l relay up to 63a as well as molded case circuit breaker (mccb) up to 800 a, 3). mode selector switch for mcb or mccb testing, 4). auto ranging digital time interval meter, 5). compatible for no/nc auxiliary trip contact selection, 6). size 600*500*420 mm, approx wt. 75kg input 230v 50hz ,it should be portable and trolly mounted. it should be with completed accessories such as wires/cable and connectors of suitable size. [ warranty period: 30 months after the date of delivery ] ]
Tender For repair and maintenance of wss bhadwana (sh:-repair of 40 hp. induction motor kirloskar make) set no.1 (2) lwss shri mata chintpurni (sh:- replacement of new mccb (molded case circuit breaker in placed od damaged mccb)
Tender For corrigendum : supply and installation of mcb/mccb testing kit with dual mode outputs i.e. mode no.- 01) - 0.01 a to 100 amps ac for mcbs mode no.- 02) 100a to 2000 a ac for mccbs. make :- r k industries ,yamini, starlight, megger, fluke , ssge only. . features: 1) main isolated ac injection currents, 2). two in one test kit to test miniature circuit breaker (mcb) bimetal o/l relay up to 63a as well as molded case circuit breaker (mccb) up to 800a, 3). mode selector switch for mcb or mccb testing, 4). auto ranging digital time interval meter, 5). compatible for no/nc auxiliary trip contact selection, 6). size 600*500*420 mm, approx wt. 75kg input 230v 50hz. note: (1) oem/authorized dealer proof of purchase submit along with material supply. (2) test bench equipment lab testing report of government approved lab submit along with material supply.. (3) warranty of entire unit must be require of minimum 60 months. [ warranty period: 60 months after the date of delivery ] ]
Tender For supply of ed 65k 100 ampere 02 pole molded case circuit breaker, cat.-ed2100d01f01v4, style-6604c15g02 240v ac-65ka, 125v dc-10ka, emd part no. 40100201. make-eaton, cutler-hammer, emd. [ warranty period: 30 months after the date of delivery ] ]
Tender For corrigendum : stage contract for carrying out various electrical maintenance works including sitc, itc of various line materials and distribution substations and dismantling of existing deteriorated out lived electrical infrastructure for the year 2026-27 under th - supply, installation, testing and commissioning of 3-phase 25 kva distribution transformers with bimetallic terminal connectors energy level-2, (al wound ), and with lv cable box having detachable aluminium gland plate, supply, installation, testing and commissioning of, 3-phase 63 kva distribution transformers with bimetallic terminal connectors energy level-2, (al wound ), and with lv cable box having detachable aluminium gland plate, supply, installation, testing and commissioning of, 3-phase 100 kva distribution transformers with bimetallic terminal connectors energy level-2, (al wound ), and with lv cable box having detachable aluminium gland plate, supply, installation, testing and commissioning of, 3-phase 200 kva distribution transformers with bimetallic terminal connectors energy level-2, (al wound ), and with lv cable box having detachable aluminium gland plate, supply, installation, testing and commissioning of, 3-phase 250 kva distribution transformers with bimetallic terminal connectors energy level-2, (al wound ), and with lv cable box having detachable aluminium gland plate, sitc of 11 mtr long st poles 410, sp-56 including transportation, manual, mechanical carriage, delivery at site with pit excavation, refilling the pit with soil, boulders., sitc of 9 mtr long st poles 410, sp-33 including transportation, manual, mechanical carriage, delivery at site with pit excavation, refilling the pit with soil, boulders., sitc of 8 mtr long st poles 410, sp-15 including transportation, manual, mechanical carriage, delivery at site with pit excavation, refilling the pit with soil, boulders., sitc of 8 mtr long pcc poles including manual, mechanical carriage, excavation of pole pits with inscription of permenent marking on each pole "name of scheme-2019-20/xx" (xxx mean pole numbers say 01,02...) in white paint in backgound of green paint at conspicious place, providing & fixing of pole earthing as per rec standard as per j-1 (spiral earthing) drawing, supply,fixing of spike earthing rod 20mm 2,5 mtr long with gi strip (25x3)mm, supply and painting of each pole 1 coat red oxide paint and 2 coats of aluminium paint (@ 1 ltr/pole red oxide paint and 1 ltr/pole aluminium paint), providing, errection, testing & commissioning of channel cross arms, v-cross arms, sub-station channels & angle iron braces, transformer beltings, including back clamps for fixing cross arms etc fabricated out of galvanized iron of different sizes (rec standard) & to be fixed with gi nuts & bolts and washers., providing, errection, testing & commissioning of channel cross arms, v-cross arms, sub-station channels & angle iron braces, transformer beltings, including back clamps for fixing cross arms etc fabricated out of mild steel of different sizes (rec standard) & to be fixed with gi nuts & bolts and washers., providing & and fixing of 11 kv pin insulators (polymer) with pins ( 5 kn), providing & fixing of 11 kv, g.o ab switch , 3-phase, 200a (09 insulator post type) with arragement for pad locks & operating rod . the operating rod should be g.i pipe (b-class) of 25 mm dia of requisite length., providing & fixing of 11 kv horn, gapfuse 3-phase 100a, providing & fixing of 11kv link set 3-phase, 200 a (station type), sitc of 11kv isolator double break, 3-pole, 630 amps, horizontal mounting type , with earth switch, providing & fixing supply and installation of gapless surge arrestor,9 kv,10 ka, la with (polymer) housing, station type, providing & fixing of lt fuse set of suitable capacity for 63kva,100kva,200kva (as per tender drawing attached), providing & fixing of 11 kv disc insulators (polymer) complete with fitting( 4
Tender For supply of 400 amps 4 pole 35 ka molded case circuit breaker(mccb), rated voltage: 240/415volt , 50 hz ac as per is/iec60947,make: l&t, anchor, havells or equivalent. [ warranty period: 30 months after the date of delivery ] ]