Get complete information related to latest Horn Gap Fuse Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Horn Gap Fuse Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Horn Gap Fuse Tenders.
Tender For supply of miscellaneous electric items - steel tubular 9 mtr. long pole (st-410 sp33) , acsr weasel conductor 6/1/2.59 mm , 11 kv go, ab switch 3-phase, 3-pole, 200 amp vertical type with rod heavy duty , back clamp for 9 mtr. pole with fitting , 11 kv horngapfuse set (hg set) 3-phase 400 amp polymer type heavy duty , la set station type (gapless surge arrestor, 9kv, 10 ka, la with polymer housing station type heavy duty) , xlpe pvc cable single core 300 mm sqr. (300 sq mm cable 1.1 kv grade, pvc insulated standard conductor frls type) , 11 kv polymeric pin insulator 12 kv, 5 kn, lighting impulse 75 kv positive and 80 kv negative, creepage distance 320 mm , insulator disk 11 kv (11kv polymeric composite discs insulator with pin and gl fittings, 12 kv, mainfalling load 45 kn, lighting impulse 75 kv positive and 80 kv negative, creepage distance 320 mm) , channel 100.00 mm x 50.00 mm x 5.00 mm (10 feet long) , nut bolt full thread with washer 4"/6" heavy duty , wedge connection / pg clamps , danger plate and clamps , g.i. bracket wire for anti climbing , 3 phase 4 wire trivector meter with ct/pt unit , aluminium thimble 185 mm , lv distribution box for 400 kva dtr with mccb for incomer & sfu's for outgoing circuits , stay set (gi rod with clamp) - galvanised stay set with 50x8mm stay clamp, gav. insulator (02 nos.) anchor plate (200x200x6mm) nut-bolt 2 nos. turn-buckles, 1.8 m long 16 mm diameter solid g5 stay rod & 7/3. 15 mm dia gi standard wire complete , g.i. guy rod complete with clamp and insulator , anti climbing device with clamp , guy / stay wire 7/14, galvanized steel, typically hot-dip zinc-coated for corrosion resistance , giv cross-arm with top bracket and gi channel-arm including clamp (gi v cross arm with top bracket including clamp and gl channel x-arm including clamps and braces) , channel 75 x 75 x 6mm (10 feet long) , g.i. earthing wire 8/10 mm
Tender For corrigendum : stage contract for carrying out various electrical maintenance works including sitc, itc of various line materials and distribution substations and dismantling of existing deteriorated out lived electrical infrastructure for the year 2026-27 under th - supply, installation, testing and commissioning of 3-phase 25 kva distribution transformers with bimetallic terminal connectors energy level-2, (al wound ), and with lv cable box having detachable aluminium gland plate, supply, installation, testing and commissioning of, 3-phase 63 kva distribution transformers with bimetallic terminal connectors energy level-2, (al wound ), and with lv cable box having detachable aluminium gland plate, supply, installation, testing and commissioning of, 3-phase 100 kva distribution transformers with bimetallic terminal connectors energy level-2, (al wound ), and with lv cable box having detachable aluminium gland plate, supply, installation, testing and commissioning of, 3-phase 200 kva distribution transformers with bimetallic terminal connectors energy level-2, (al wound ), and with lv cable box having detachable aluminium gland plate, supply, installation, testing and commissioning of, 3-phase 250 kva distribution transformers with bimetallic terminal connectors energy level-2, (al wound ), and with lv cable box having detachable aluminium gland plate, sitc of 11 mtr long st poles 410, sp-56 including transportation, manual, mechanical carriage, delivery at site with pit excavation, refilling the pit with soil, boulders., sitc of 9 mtr long st poles 410, sp-33 including transportation, manual, mechanical carriage, delivery at site with pit excavation, refilling the pit with soil, boulders., sitc of 8 mtr long st poles 410, sp-15 including transportation, manual, mechanical carriage, delivery at site with pit excavation, refilling the pit with soil, boulders., sitc of 8 mtr long pcc poles including manual, mechanical carriage, excavation of pole pits with inscription of permenent marking on each pole "name of scheme-2019-20/xx" (xxx mean pole numbers say 01,02...) in white paint in backgound of green paint at conspicious place, providing & fixing of pole earthing as per rec standard as per j-1 (spiral earthing) drawing, supply,fixing of spike earthing rod 20mm 2,5 mtr long with gi strip (25x3)mm, supply and painting of each pole 1 coat red oxide paint and 2 coats of aluminium paint (@ 1 ltr/pole red oxide paint and 1 ltr/pole aluminium paint), providing, errection, testing & commissioning of channel cross arms, v-cross arms, sub-station channels & angle iron braces, transformer beltings, including back clamps for fixing cross arms etc fabricated out of galvanized iron of different sizes (rec standard) & to be fixed with gi nuts & bolts and washers., providing, errection, testing & commissioning of channel cross arms, v-cross arms, sub-station channels & angle iron braces, transformer beltings, including back clamps for fixing cross arms etc fabricated out of mild steel of different sizes (rec standard) & to be fixed with gi nuts & bolts and washers., providing & and fixing of 11 kv pin insulators (polymer) with pins ( 5 kn), providing & fixing of 11 kv, g.o ab switch , 3-phase, 200a (09 insulator post type) with arragement for pad locks & operating rod . the operating rod should be g.i pipe (b-class) of 25 mm dia of requisite length., providing & fixing of 11 kv horn, gapfuse 3-phase 100a, providing & fixing of 11kv link set 3-phase, 200 a (station type), sitc of 11kv isolator double break, 3-pole, 630 amps, horizontal mounting type , with earth switch, providing & fixing supply and installation of gapless surge arrestor,9 kv,10 ka, la with (polymer) housing, station type, providing & fixing of lt fuse set of suitable capacity for 63kva,100kva,200kva (as per tender drawing attached), providing & fixing of 11 kv disc insulators (polymer) complete with fitting( 4
Tender For corrigendum : annual stage contract for supply, carriage upto divisional store, unloading etc. of store items required by electric division sopore under m and r for the f.y 2026-27 - supply of steel tubular poles of sizes, st pole 11 mtr. long (st-410 sp56), st pole 9 mtr. long (st-410 sp33), st pole 8 mtr. long (st-410 sp15), supply of pcc poles of sizes, pcc pole 9 mtr. long (wl =300 kg), pcc pole 8 mtr. long (wl =250 kg), supply of acsr conductor of sizes, 0.03 acsr conductor (weasel), 0.05 acsr conductor (rabbit), 0.1 acsr conductor (dog), supply of sub-station items, supply of 11 kv link set (post type) of rated capacity 200 amp (polymer type) , supply of 11 kv link set (post type) of rated capacity 200 amp (porcelain type) , supply of 11 kv link set (line type) heavy duty having rated capacity 600 amp (polymer type) , supply of 11 kv link set (line type) heavy duty having rated capacity 600 amp (porcelain type) , supply of 11 kv gang operating, ab switch 3-phase, 3-pole, 200 amp, vertical type comprising of 9 no. insulators, pipes and lock pad etc complete job (polymer type), supply of 11 kv gang operating, ab switch 3-phase, 3-pole, 200 amp, vertical type comprising of 9 no. insulators, pipes and lock pad etc complete job (porcelain type), supply of gapless surge arrestor, 9 kv, 10 ka, lighting arrestor with polymer housing, stn. type (rashtriya, spark or yamuna make), supply of gapless surge arrestor, 9 kv, 10 ka, lighting arresor with porcelain type housing, stn. type (rashtriya, spark or yamuna make), supply of 11 kv horngapfuse set 3-phase 200 amp (polymer type), supply of 11 kv horngapfuse set 3-phase 200 amp (porcelain type), supply of g.i.wire no. 8 swg, supply of guy insulators (11 kv), supply of bobin insulators 40 mm, supply of pole collars of 50x8mm galvanized flat iron with galvanized nuts and bolts of sizes, supply of gi barbed wire for anticlimbing, supply of anticlimbing devices, supply of 11 kv danger plate with clamp, supply of galvanized nuts and bolts of sorts, supply of galvanized channel iron cross arm (100x50x6mm), (75x40x6mm) duly fabricated including clamps and galvanized nuts and bolts of sizes with washers of sizes, supply of galvanized angle iron brace (50x50x6mm) of sizes duly fabricated including clamps of different sizes and galvanized nuts and bolts of sizes with washers of sizes, supply of galvanized v cross-arms duly fabricated of size 75x40x6mm channel iron cross arms including clamps of different sizes and galvanized nuts and bolts of sizes with washers of sizes, supply of m.s. channel iron cross arm (100x50x6mm), (75x40x6mm) duly fabricated including clamps and nuts and bolts of sizes with washers of sizes duly painted with redoxide and and aluminum paint, supply of m.s. angle iron brace (50x50x6mm) of sizes duly fabricated including clamps of different sizes and nuts and bolts of sizes with washers of sizes duly painted with redoxide and and aluminum paint, supply of m.s. v cross-arms duly fabricated of size 75x40x6mm channel iron cross arms including clamps of different sizes and nuts and bolts of sizes with washers of sizes duly painted with redoxide and and aluminum paint, supply of f-top fabricated of galvanized channel iron cross arm (75x40x6mm) 1.5 long and of 6 horizontal length including clamps, collars, nuts and bolts complete with washers etc., supply of protection items (dp mcb c-curve series of breaking capacity 15 ka) (schnieder/siemens/legrand make), 6 amp, 10 amp, 16 amp, 25 amp, 32 amp, 40 amp, 63 amp, supply of protection items (tp mcb c-curve series of breaking capacity 15 ka) (schnieder/siemens/legrand make), 16 amp, 25 amp, 32 amp, 40 amp, 63 amp, supply of protection items (tp mccb wih enclosure complete duly fiited over galvanized angle iron stand/frame duly grouted) (schnieder/siemens/legrand/l&t - d sine series make), 32 amp (breaking capacity 25 ka), 40 amp (breaking capacity 25 ka), 63 amp (breaking capacity 25 ka), 100 amp (breaking capacity 25 ka),
Tender For supply of miscellaneous electric items- steel tubular 9 meter long pole (st-410 sp3, steel tubular 8 meter long pole (st-410 sp1:, 16 kn polymer shackle insulator, 1.1 kv (low tension), go set 11 kv hd, ab switch 3 phase, 3-pole 200 amp, vertical; type with rod heavy duty, 11 kv horngapfuse set (hg set) 3-phase 4 amp polymer type heavy duty, galvanized nuts and bolts full thread with was 4" & 6" heavy duty, anti climbing device with clamps, galvanized stay set with 50*8 mm stay clamp guy insulator (02 no.), anchor plate (200*6mm nuts-bolts, 2 nos turn buckets, 1.8m long, 16 m diameter solid gs stay rod & 7/15 mm dia gi standard wire complete., guy/stay wire 7/14, galvanized steel, typicall hot-dip zinc-coated for corrosion resistance, guy insulator, led street lights 70/72 watt, pressure die ca aluminum housing only, system lumen output 120lm/w, cct: 5700-6500°k, cri≥ 80, thd≤1 surge 4kv, pf >= 0.95 ip66, warranty minimum -years, pvc cable 3 core 2.5 sqmm, mukki clamps, rabbit conductor acsr 50 sq.mm, gi u-clamp for shackle insulator with pin / nu, lt line spacers, high quality rigid pvc (poly vinyl chloride) or polypropylene, with uv stabilization for weather resistance
Tender For stage contract for supply of workshop/line material as and when required during financial year 2026-27 or till next contract gets finalised - electrical store/workshop items/: as per is standards and kpdcl approved vendors only wherever applicable, bush rods 12mm(lt) of standard make, bush rods 19mm(lt) of standard make, bush rods 25mm(lt) of standard make, bush rods 30mm(lt) of standard make, ht bush for dts of standard make(33/11kv as per requirement and relevant is), lt bush set for 250kva dt of standard make, lt bush set for 63kva dt of standard make, lt bush set for 100kva of standard make, aluminum thimbles 95sqmm of standard make, aluminum thimbles 120sqmm of standard make, aluminum thimbles 185sqmm of standard make, aluminum thimbles 240sqmm of standard make, aluminum thimbles 300sqmm of standard make, soldress clamp for 630kva, soldress clamp for 400kva of standard make, soldress clamp for 250kva of standard make, soldress clamp for 100kva & 63kva, gi channel/angle/flat/clamps of sizes (as per requirement), gi v cross-arm with top bracket including clamp(2 nos), 11 kv gapless surge arrestor,9 kv ,10 ka ,la with polymer housing, stn. type, 11kv go, ab switch 3-phase, 3-pole, 200 amp, vertical type, 11 kv horngapfuse set 3 phase 200a, 11 kv heavy duty link set (polymer) line type with 6mm copper blade and 02 no. 8ft. gi channel, clamps and nuts and bolts, 11 kv pin insulators (polymer/porcelain) with pins(5kn), 11kv polymeric composite disc insulator 12kv,min failing load 45kn, lighting impulse 75kv positive and 80kv negative, creepage distance 320mm, lt shackle with mukhi clamps including gi nuts & bolts, gi nuts & bolts of sizes with full thread, manilla rope, gi wire 8 swg, suspension/tension clamp with eye hook as per kpdcl standards, insulating piercing connector (10-95sqmm), straight through cable jointing kit for 35/50sqmm ltab, straight through cable jointing kit for 75/95/120sqmm ltab, heat shrinkable outdoor cable termination kit, 50sqmm lt ab cable (3x50+1x16+1x35) sqmm xlpe (1.1kv, 3+1c, al), 35 mm ab (ht) cable (3x35+1x35 mm ) xlpe, dpc aluminium of sizes 13/14/16/18swg of standard make, super enamelled(se) of sizes 13/14/16/18/21swg of standard make, lathoride paper 10 mil of standard make, exchange of 1kg fresh al dpc by scrap dpc, exchanege of 1 kg fresh bush rods by scrap bush rods, lathoride paper 20 mil of standard make, ht paper 3 mil of standard make, hard card board 1/1.5/2/3mm of standard make, fiber tubes of standard make, cotton tape/ nawar of standard make, cork washers (32x12)5mm, cork washers (50x28)5mm, cork washers (110x74)5mm, cork washers (45x20)5mm, cork washers (60x32)5mm, cork washers (70x45)5mm, cork washers (90x50)5mm, cork sheets(24x36) 3 mm, cork sheets(24x36) 4mm, cork sheets(24x36) 5mm, cork strip(40x3) mm, cork strip(40x5) mm, oil seals for 250kva of standard make, oil seals for 100kva & 63kva of standard make, m seal, cotton tap 1" size (length 35 meter), nawar tap 1 size 35 meter long, tape roll pvc, old saree/doti cloth, insulating gum of standard make, aluminum strip of sizes (3/6, 3/7, 4/8, 4/10 mm etc ) of standard make, rubberized cork sheet 4mm thick, 2 feet *3 feet, rubberized cork sheet 3mm thick, 2 feet *3 feet, ht brown paper 3.0/2.5 mil, packing sheet (1mm)press card board 1/2/3mm, synthetic enamel paint grey colour, varnish dr.beck/empire, glass wool sleeves of sizes, fevicol, backlite tubes 1/2 inch,(1mtr length), packing gutties, electrical grade kraft paper,4mil, rubber washers ( m-12 ht oil seal),, rubber washers ( m-12 lt oil seal),, rubber washers ( m-16 lt oil seal),, rubber washers ( m-20 lt oil seal),, rubber washers ( m-25 lt oil seal),, rubber washers ( m-30 lt oil seal),, fiber glass sleeves 2mm, fiber glass sleeves 3mm, fiber glass sleeves 4mm, fiber glass sleeves 5mm, fiber glass sleeves 6mm, fiber glass sleeves 8mm, fiber glass sleeves 10mm, fiber glass sleeves 12mm, fiber glass sleeves 15mm, oxygen cylinder for welding with water c
Tender For purchase of equipment for electronics and communication department - 100mhz/2 channel digital storage oscilloscope(dso), sample rate 1gsa/s, record length - 14mpts, wavwform capture rate-400,000 wfm/s, serial decode/trigger functions, advanced math operations-fft, d/dt, integrate, square root 38 parameters automatic measurements, 7 inch tft lcd display, newest generation of spo(super phosphor oscilloscope) technology support usb host, usb device (usb tmc), lan (vxi-11), gpib (optional), pass/fail, trigger out, impts, 500uv/div sensitivity, 2 channel 3mhz function generator with modulation, 3 mhz function generator with sine, square, triangle, ramp, pulse, ttl & dc, frequency range 0.3hz to 3mhz, amplitude and frequency display, internal and external modulation by any signal by am,fm,pwm,pam,fsk,ask, auto ranging 40mhz frequency counter, auxiliary generator with frequency 20hz-20khz, square wave rise time- better than 50ns, dual channel power supply 0-30v continuous variable regulated 30v-2a, 0 to +/- 15v-1a, 5v-5a multiple power supply, dc 0 to 30v/2a, 0 to +/- 15v/1a tracking, 4.5 to 5.5 / 5a digital display for voltage and current protection against overload and short circuit, adjustable current limiter, constant current & constant voltage, multimeter - digiital - dc voltage 1000v, ac voltage 1000v, dc accuracy +/- 1% +3 digit, current dc 10amp, ac 10 amp, dc accuracy +/- 1.5%+3 digit, ac accuracy +/- 1.5% +3 digit, resistance 40 mohm - resistance accuracy +/- 1.5% +3 digit, capacitance :1000uf; capacitance accuracy +/- 5% + 5 digit. cat iii 600v saftey rating, bigger display with bright white backlight. over voltage indicator, frequency and temperature measurements, voltage, resistance, continuity, capacitance measurements, input terminal for ac and dc current measurements upto 10a, diode test, data hold, min/max ammeter and voltmater included.
Tender For supply of 2.2 kw ac crane drive , 5.5 kw ac crane drive , 11.0 kw ac crane drive , 22.0 kw ac crane drive , 37.0 kw ac crane drive , 55.0 kw ac crane drive , 75.0 kw ac crane drive 3 phase, digital ac crane drive 2.2 kw, ac drive should be suitable for heavy duty operation of 2.2 kw. offered ac drive should be suitable for crane-hoist operation. if, separate software required for crane application, it must be clubbed with supply of material. ac input voltage: 380 to 480v ac 10%, 3 phase, 3 wire, 50 hz; mode of control: bi-directional fully controlled 3-phase ac; speed regulation: 1% of base speed; braking: suitable dynamic braking resistance and chopper unit (external or in-built); acceleration time: 0.1 to 1000s or better; deacceleration time: 0.1 to 1000s or better; overload: 150%-1min, 200%-3.0s; ambient temperature: 0 to 50 c (derating shall not occur below 50 c. in the event that derating occurs below 50 c, the supplier shall provide a higher-rated drive to match the requirement); rated current at 50 c: min. current should be 5.5 amps at 50 c; high starting torque at low speed: 200% starting torque at 0.3 hz; two analog inputs: two nos. analog inputs having signal voltages of 0 to 10 vdc or 4 to 20 ma (configurable); two analog outputs: two nos. analog outputs having signal voltages of 0 to +/-10 vdc or 4 to 20 ma (configurable); six digital inputs: pnp/npn; one relay output: with short-circuit and overload protection; two digital outputs: with short- circuit and overload protection; brake release signals: outputs braking signals based on inverter operating conditions to prevent cargo bed rollback and overrunning; load adaptive control: when the actual load level is lower than the configured load level, the system can be operated at a ratio-multiplied speed (in terms of the configured frequency), resulting in significantly better efficiency; load ) /bid number : gem/2026/b/7563714 * /dated: 20-05-2026 & & / bid document 1 / 29 frequency), resulting in significantly better efficiency; load limiter: maintains the safety and rescuability of suspended loads by stopping when excessive torque is detected and by allowing operation only in the direction opposite to that in which the excessive load was detected; cooling capacity degradation alarm: detects and displays cooling capacity drop due to cooling fin clogging caused by dust and cooling fan airflow reduction; igbt life expectancy forecasting: estimates the power cycle life expectancy of the main circuit s igbt semiconductor device temperature due to frequent acceleration and deceleration stoppages, and displays the estimate before the design life is reached; protection: it must have all standard protections like stall protection, instantaneous power failure, single phasing, over voltage, under voltage, over current, inverter overload, thermal overload etc; display console: it must have alpha numeric display console for programming of drive, fault display and operating condition; dynamic qr code: it must have dynamic qr code for trouble shooting; tuning facility: it must have auto tuning facility. this must enable perfect matching of motor coupled to load with regards to optimum acceleration time, deceleration time, speed regulation etc; drive programming software: suitable drive programming software along with necessary connecting cable and adapter for connection with laptop and drive should be provided to get online with the offered drive (laptop not in scope); automatic voltage regulation: it must have automatic voltage regulation function to maintain high starting torque even at reduced voltage; regenerative option: it must be capable of regenerative operation; communication protocol: modbus (rtu/serial) or ethernet (tcp/ip); make of drives: fuji- electric/yasakawa/schneider/abb only; suitable dynamic breaking resistance unit of 60% wattage rating of drive, however the value of resistance is to be decided by manufacturer as per their technical manual for crane-ho