Web Analytics Made Easy - StatCounter

Hydromechanical Work Tenders

Get complete information related to latest Hydromechanical Work Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Hydromechanical Work Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Hydromechanical Work Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :41052818 Due date: 04 Aug, 202504 Aug, 2025 NA
Tender For works contract for mechanical and electrical "furnishings & fittings including interior & exterior plumbing fittings / activities with coach lowering in lws/ddg lhb type coaches as per scope of work.

Central Government / Public Sector

CTN :41011115 Due date: 19 Jul, 202519 Jul, 2025 49.27 Lacs
Tender For procurement of mechanical and pneumatic spares at iocl budge budge bottling plant - 8 teeth sprocket material cast steel grade-1030, bush-gunmetal/bronze, bore 40mm as per iocl specification/sample, drum pulley (roller)with ball bearing for conveyor chain. bore 40mm.as per drawing provided, 14 teeth conveyor chain half-split sprocket, hole dia65mm, cast steel, grade1030, as per iocl sample, 14teeth conveyor chain sprocket, hole dia-(60mm-65mm), cast steel, grade1030asperi oclsample., conveyor shaft dia range-(40mm-60mm) length range-(370mm-500mm) material grade en8/9,as per iocl specification/sample., conveyor drive unit counter weight pair as per ioc sample, conveyor shaft with key dia-65mm, length-(850mm-870mm), key slot as per requirement, material grade en8/9asperiocsample, drive sprocket-duplex-1"pitch-27teeth/32teeth, bore-as per site requirement materialgrade-en-6, duplex sprocket-1"pitch-17teeth/19teeth/21teeth/23teeth, bore as per site requirement, material grade-en-6, drive sprocket-duplex-1"pitch-48teeth/38teeth, bore-as per site requirement material grade-en-6,, industrial chain duplex-1"pitchmake-diamond-1 set of 10ft length., plumber blocku-213, make skf or equivalent, plumber blocku-212, make skf or equivalent, coupling set no-150 with rubber bush bore&key slot as per site requirement; material cast iron, coupling rubber bush(star) no-150, coupling rubber bush(star) no-110, coupling setno-110 with rubber bush bore &key slot as per site requirement; material cast iron, hot air seal linear bearing hiwinhg25, malleting hammer as per ioc sample, lpg hose for carousel 900mm length as per iocsample, lpg hose for carousel 800mm length as per iocsample, pneumatic tube 8mm janatics make 100 metre, pneumatic tube 6mm janatics make 100 metre, pneumatic tube 4mm janatics make 100 metre, nylon stopper roller with s.s bush fittings. outerdia-50mm innerdia-16.5mm thickness-25mm as per ioc, black (carbonfilled) nylon stopper roller with s.s bush fittings. outerdia-(13mm-60mm) innerdia-19mm, thickness-43mm as per requirement, 1/2inch 2mts teflon hose with s.s and asbestos bedding for hot air seal as per ioc sample, 1/2inch 600mm teflon hose with s.s and asbestos bedding for hot air seal as per ioc sample.length may vary by 500 mm up or down, detachable type conveyor chain, twin arm stopper complete set(left/right)as per ioc sampler, gd/pt cylinder clamping as per ioc sample, wd-40 spray - 450ml, crc-2-26 spray - 500ml, loctite - 542, htpc conical buffer as per ioc sample, htpc cylinderical buffer as per ioc samp, ss guide rod for kosan carousel as per ioc sample, centrally located drive as per equipment, tail end as per equipment specification, straight sections as per equipment specification, 5hp 14mpm drive unit, smc/norgan (50*500) cylinder tie rod type/profile, norgren cylinderpra/802050/450 tie rod/profile, smc/norgen bore 50 length 550 profile type, smc cylindercp96sdb50-320c, smc cylindermbb50-125z, smc cylindercp96sdb50-300c, smc cylindercp96sdb50-350c, smc cylindercp96sdb63-100c, norgren(cylinder+mounting )ra/8050/m80/, norgren cylinderra/802050/m/80, norgren cylinderra/802050/m/100, norgren cylinderpra/802050/m/250, festo make antenna valvev-3-1/4-b, janatics make push pull valve d5255er61, 8x1/4 male connector, 8x1/4 elbow connector, 6x1/8 male connector, 6x1/8 elbow connector, 8x8 strraight connector, 8x6 straight connector, 6 x 1/4 elbow connector, festo make connector4*4, festo make connector4*6, festo make connector6*6, 6 x 1/4 male connector, metalworks make sov7010021100, metalworks make sov7020021100

State Government

CTN :40980759 Due date: 22 Jul, 202522 Jul, 2025 NA
Tender For supply delivery and replacement of spares for sub-station at mandalkuli water supply scheme , raipur block under bankura mechanical division, phe dte. - "control transformer supply80 va, 240 v / 110 v", "aux contractor supply (4 no 4 nc)make: siemens / abb, coil voltage: 110 v ac", "pcb relay card supply for avr as per existing circuit ", voltage controller potentiometer (1k) supply, "1100 va ups supply output power wattage 660w or equivalent , input-50 hz , wide input voltage range 145-290 v, 2x 7.2 ah (or equivalent) battery , provides 30-90 min power back upmake: apc, input: 230 v ac", "240 sq. mm. x 3 core, 11 kv grade, indoor type, heatshrinkable end termination kit supply ", "240 sq. mm., 11 kv grade, indoor type, heatshrinkable kit jointing charges", "avr throughout inspection and control operation checking and rectification by opening the cover , checking the throughout circuits with aux. contractor replacement charges, pcb relay card with voltage controller potentiometer replacement charges, control transformer replacement charges, old ups replacement and new ups installation charges fixing of heat srinkable kit & other as per direction . ", supply and delivery of following spares for battery charger panel:, supply of 65 ah smf vrla battery with 6 nos cell, polyproplene container make: exide, consisting of 9 nos. 12 v batteries (model-ep 65-12 or equivalent), "charges for old defective battery rack by disconnection all the electrical circuit and fitting fixing of the new battery rack fittings,connection of all batteries checking otesting for a certain period. ", "supply of 2.5 sq. mm x 4 core cu armored cable forbattery charger panel to 3 panel vcb , as per is-7098 (part-i )", gland supply for 2.5 sq mm x 4 core cu armored cable, laying charges of 2.5 sq. mm x 4 core cu armored cable, "charges for glanding & socketing for 2.5 sq mm x 4core cable for battery charger panel: as per direcrion of eic", "supply and delivery of following spares for 400 kva, 11 kv/433 v, transformer-1 & 2:", oti (4 inch. dia) supply make: ptci, "wti (4 inch. dia) supply make: ptci", oti replacement charges, wti replacement charges, "supply of 2.5 sq. mm x 10 core cu armored cable for 3panel vcb to transformer-1 & 2 as per is-7098 (part-i ) ", gland supply for 2.5 sq mm x 10 core cu armored cable, laying charges of 2.5 sq. mm x 10 core cu armored cable , supply of 2.5 sq mm cu pin lugs , supply of 2.5 sq mm cu fork lugs, "charges for glanding & socketing for 2.5 sq mm x 10core cable of 400 kva, 11 kv/433 v, transformer-1 & 2: as per direction of eic", supply and delivery of following spares for single panel vcb:, 240 sq. mm. x 3 core, 11 kv grade, indoor type, heat shrinkable end termination kit supply, 240 sq. mm., 11 kv grade, indoor type, heat shrinkable kit jointing charges, 200-watt space heater supply make: reco, 230 v , "thermostat supplymake: elcon gold, model: mm-106,range: 30? c - 110? c, 15 amp., 230 / 250 v ac", "3 nos. space heater along with 1 no. thermostatconnection wiring charges as per direction of eic", supply and delivery of following spares for 3- panel vcb: , "240 sq. mm. x 3 core, 11 kv grade, indoor type, heatshrinkable end termination kit supply", "240 sq. mm., 11 kv grade, indoor type, heat shrinkablekit jointing charges", 200-watt space heater supply make: reco, 230 v , "thermostat supplymake: elcon gold, model: mm-106,range: 30? c - 110? c, 15 amp., 230 / 250 v ac", 2.5 sq. mm. s/c, 1.1 kv grade control cable supply for space heater and thermostat wiring , "2 nos. space heater along with 1 nos. thermostatconnection wiring charges for each panel as per direction of eic", "3 nos. space heater along with 1 no. thermostatconnection wiring charges as per direction of eic", attending the fault at mandalkuli, bankura district with carrying different testing, servicing kit/machine like insulating resistance checking machine (1 kv, 2.5 kv, 5 kv) 3 phase variac, current injection machine/ kit, voltage

State Government

CTN :40985123 Due date: 14 Jul, 202514 Jul, 2025 30.86 Lacs
Tender For repair maintenance of of electrical and mechanical services installed at jpc hospital, shastri park, delhi. sub head supplying and replacement of ei fittings and miscellaneous ei works as and when required at site

State Government

CTN :41007627 Due date: 16 Jul, 202516 Jul, 2025 NA
Tender For replacement of 200mm and 150mm dia damage c.i. water supply pipe line and fittings by m.s. pipe line and pipe line fittings with supplying of necessary mechanical fittings at m.s. mukherjee road (east) pump house in ward no.21,

CTN :40956344 Due date: 25 Jul, 202525 Jul, 2025 NA
Tender For works contract for interior partial mechanical furnishings & fittings works in vande bharat train rake (coach composition of vande bharat rake - dtc1-1 coach, dtc2-1 coach ,mc1-5 coaches, mc2-5 coaches,ndtc-1 coach, ndtc/ec-1 coach , ndtc/ec3-1 coach,tc-5 coaches , total- 20 coaches per vb rake ) as per scope of work for 9 vande bharat rake .

State Government

CTN :40950683 Due date: 15 Jul, 202515 Jul, 2025 22.31 Lacs
Tender For camc including consumables, repairs and replacement of defective parts of 1000 lpm ogp along with allied electro mechanical equipments along with operational charges for 01 year at gmc ah rajouri - comprehensive annual maintenance (camc) camc of oxygen generation plant ( airsep make 1000 lpm complete unit) which includes periodic servicing/maintenance and repairs of complete ogp unit (consisting of oxygen modules, air compressors (110 kw ingersoll rand make, air dryers (trident make), filtration assemblies, air tanks, oxygen tanks, interconnecting pipeline, control valves, indicators, sensors, pressure & purity meters, ups, electric panel, valve panel, and other allied accessories, etc.), (including topping/replacement of molecular sieve (zeolite/alumina/any other chemical as per requirement), copper pipeline from plant room upto patient beds, allied equipments such as main 630 amp. electric distribution cum changeover panel, mccbs/acbs, 400 kva avr (ae make), 250 kva avr (jaima make), 400 kva dg set sudhir power make (including replacement of batteries), amf panel, cabling, lightening arrestor, earthing, etc., other miscellaneous items of the plant room such as lighting, exhaust fans, ceiling fans, cctvs with inverter battery set, electric wiring and fittings, refilling of abc type fire extinguishers, other minor civil items, etc. the job also includes repair/replacement of defective pipeline from air compressors to air tanks/air dryers to psa tower in order to make it leak proof.the technicians for operation will be responsible for preventive maintenance, minor repairs/settings on a routine basis. major breakdowns of the plant equipment to be repaired by the firm through oems/open market workshops, etc. for maintaining the plant in working condition the firm will bear all charges of material including consumables, labour, transportation and all taxes as applicable.any other item of the oxygen plant not mentioned in the above description, but found necessary for the functioning of the plant, is deemed to be covered under the oc/camc contractfirst year, second year, third year, fourth year, fifth year, sixth year, seventh year, operational contract (oc)24x7 operation of 1000 lpm psa oxygen generation plant ( airsep make complete unit) and it s all allied equipments including power backup. the technicians for operation will also be responsible for preventive maintenance, minor repairs/settings on a routine basis. wages of the operators/technicians (3 nos + 1 no) for 01 year (12 months) having experience of similar work.first year, second year, third year, fourth year, fifth year, sixth year, seventh year

Central Government/Public Sector

CTN :40945627 Due date: 24 Jul, 202524 Jul, 2025 NA
Tender For supply of led based lamp unit for bl key box with constant current control and mechanical fittings, i nput 110v dc +/- 22.5% as per type no. eeic/l/bl-key-box-01 and as per els/ajj drawing no.- trsacl/p/6 32. makee.e.i.corporation or equivalent. [ warranty period: 30 months after the date of delivery ]

CTN :40930099 Due date: 16 Jul, 202516 Jul, 2025 1.61 Lacs
Tender For re - wiring replacement of fans and lights fittings for heat transfer lab and mechanical lab store department of mechanical engineering in svu college of engineering tirupati.

CTN :40930101 Due date: 16 Jul, 202516 Jul, 2025 1.62 Lacs
Tender For re-wiring replacement of fans and light fittings for dynamic lab department of mechanical engineering in svu college of engineering tirupati
 Loading, Please wait...

Connect us via What's Up