Get complete information related to latest Impeller Pump Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Impeller Pump Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Impeller Pump Tenders.
Tender For alupur block: madlauda panchayat: alupur dist.: panipat annual maintenance work for water supply. - labour for opening and fitting charges, labour for pumpset lowering and lifting, providing and fixing new bowel, providing and fixing new impeller, pump spare parts & repairs - new shaft, impeller brazing and turning, pump bowl bush, gm neckring , gm neckring.
Tender For supply, delivery, installation of one number dismantling joint along with replacement of worn out spare parts, testing and commissioning of 750 mm dia. pdv and other allied works of pump unit no. 5 at cwps-ii, grww. - supply, delivery, installation, testing andcommissioning of 700 mm dia ms dismantling joints., dismantling counter weight, lever, arm, hydraulic unit etc. and all other components of the hydraulic system one by one of 750 mm dia. pump discharge valve parts by parts sequentially and cautiously as per direction of the engineer-in-charge (eic) at grww., dismantling the 750 mm dia. pdv from the existing pipe-bay, installatio/fitting-fixing of barrel-piece/flange and lifting & keeping the same on the working platform sequentially and cautiously as per diretion of the eic at grww., to and fro transportation charges of 750 mm dia. pdv from grww to workshop including loading and unloading.., dismantling all the components of 750 mm dia. pdv parts by parts sequentially and cautiously as per direction of the eic at grww/workshop., supply, delivery and fitting-fixing of drive shaft of 750 mm dia pdv sequentially and cautiously as per sample and direction of the eic at grww., supply, delivery and fitting-fixing of valve seal of 750 mm dia pdv sequentially and cautiously as per sample and direction of the eic at grww., supply, delivery and fitting-fixing of seat ring (ss 410) of 750 mm dia pdv sequentially and cautiously as per sample and direction of the eic at grww., supply, delivery and fitting-fixing of seat ring (epdm rubber) of 750 mm dia pdv sequentially and cautiously as per sample and direction of the eic at grww., supply, delivery and fitting-fixing of stub bearing bush of 750 mm dia pdv sequentially and cautiously as per sample and direction of the eic at grww., supply, delivery and fitting-fixing of drive bearing bush of 750 mm dia pdv sequentially and cautiously as per sample and direction of the eic at grww., supply, delivery and fitting-fixing of clamping ring of 750 mm dia pdv sequentially and cautiously as per sample and direction of the eic at grww., supply, delivery and fitting-fixing of end cover of 750 mm dia pdv sequentially and cautiously as per sample and direction of the eic at grww., supply, delivery and fitting-fixing of o ring of 750 mm dia pdv sequentially and cautiously as per sample and direction of the eic at grww., supply, delivery and fitting-fixing of shaft pin of 750 mm dia pdv sequentially and cautiously as per sample and direction of the eic at grww., supply, delivery and fitting-fixing of allen screw of 750 mm dia pdv sequentially and cautiously as per sample and direction of the eic at grww., supply,delivery and fitting-fixing of gland plate of 750 mm dia. pdv sequentially and cautiously as per sample and direction of the eic at grww., supply, delivery and fitting-fixing of shaft key of 750 mm dia pdv sequentially and cautiously as per sample and direction of the eic at grww., repairing the damaged portion of the hole for holding the bearing of 750 mm dia. pdv by deposting metal, boring, machining, grinding etc., all complete, as per original shape and size and direction of eic at grww.., re-aasembling all the components of 750 mm dia. pdv parts by parts sequentially and cautiously as per direction of eic at grww., performing of necessary hydro-testing of the disc and body of 750 mm dia. pdv as per direction of eic at grww., lowering from the working-bay, installation, fitting-fixing of 750 mm dia. pdv in the existing pipe-bay removing the existing barrel-piece/flanges as per direction of the eic at grww., re-assembling and re-fitting all the components of the hydraulic system like counter weight, lever, arm, hydraulic unit etc. with the existing 750 mm dia. pdv installed in the pipe-bay parts by parts sequentially and cautiously as per direction of the eic at grww., test run, operation and commissioning of the entire system of 750 mm dia. pdv as per direction of the eic at grww.
Tender For kahni 7 1/2 biswa , kahni 121/2biswa , group of 2 no. of habitations annual mtc.works for water supply. - providing and placing chuck nut on pump, making heavy duty steel sleeve, providing and fixing multi size ss stud for pump, repairing of pump housing with brass welding and turning, providing and fixing 10hp impeller, pump coupling.
Tender For corrigendum : provision of 01 x 30 kva genr with connected items as standby power requirements for sewage treatment plant under age (i) bhalra - supply, installing, commissioning and testing, water cooled, sound proof silent type, turbo charged, diesel engine driven generating set 30 kva (at 0.8 pf), 415v, 3 phase, 4 wire engine as per is: 10001/10002 and alterator as per is: 13364, complete with relay panel for automatic starting on mains failure, control panels having meters in an integral acoustic enclosure as per recommendation cpcb norms, comprising of the following:notes: quoted rates shall deemed to include the following also:-(i) supply of t and p and normal space ie., bi-hexagonal ring spanner set of 12 pieces - 01 set.(ii) fuel measuement gauge - 01 no, hand operated fuel lifting pump with steel pipe 40mm dia - 01 no, hydro meter - 01 no, set of fan belt, oil/ fuel filters initial filling of coolant (coolant-2liters).(iii) service maintenance manual along with cat part list and price list - 03 set each.(iv) make of engine and alternator will be got approved from age (i) bhalra before placing the order., (a) diesel engine. diesel engine developing suitable bhp, 1500 rpm inclusive of the following standard accessories:(i) radiator/ heat exchanger cooling system. (xiv) battery charging generator.(ii) spider coupling guard. (xv) industrial silencer.(iii) fly wheel. (xvi) lubricant oil cooler.(iv) fly wheel housing complete with starter gear ring and coupling. (xvii) flexible pipe for silencer. (v) fuel pipes. (xviii) battery volt meter.(vi) air cleaner. (xix) water temperature gauge, lub oil pressure (vii) fuel and lubricant oil filter. gauge.(viii) by pass filter. (xx) speedo meter and engine running hours meter.(ix) coolant inhibitor. (xxi) display for fault.(x) fuel pump. (xxii) turbo charger.(xi) water pump. (xii) lubricant oil pump.(xiii) self/electric starter.(b) alternator : synchronous alternator 3 phase 4 wire, 50 cycles 1500 rpm, self excited, self regulated, brushless type, 0.8 pf, 415v, ac supply, 30 kva capacity, copper wound, complete including necessary tools, mounted on strong rigid steel fabricated base frame and directly coupled through flexible coupling with diesel engine, complete all as specified and directed., (c) amf/ control panel : amf panel factory made of suitable capacity as per original equipment manufacturer make and specification or as approved by oem for dg set of capacity 30 kva of suitable size, indoor cubical type, front and back openable fabricated out of mild steel sheet 1.6mm thick grounted in floor with adequate pcc foundation and minimum consisting of following :(i) contactor of suitable size for 30 kva dg set.(ii) copper bus bar of suitable current rating and sensitivity relay set unit with auxiliary cts.(iii) electronic latch circuit with tripping indication.(iv) re-set facilities.(v) 3 phase mvr relay unit with single phase protection complete with 2 no nc auxiliary contacts.(vi) 3 phase avr relay unit complete.(vii) self sequential starting relay unit 12 volts dc complete with alarm and power contactor. (viii) electronic timer 220 volts for main contactor with 1 no nc auxiliary contactor.(ix) electronic timer 220 volts for fuel cut off operation with 1 no auxiliary contactor.(x) battery charging 2x12 volts 10 amp complete with digital voltmeter and amps meter, including trickle and boost charging, make : su-kam, amco, exide or any other make as recommended by the manufacturer.(xi) volt meter 0-500 volts panel mounting of size 96mm square with selector switch digital type.(xii) amps meter 0-100 amps with 3 nos cts, 400/5 and selector switch 96 mm square digital type.(xiii) frequency meter (45-55) hz, 415 volt, 96mm square digital type.(xiv) the amf panel should have manual by pass arrangement too in case of failure of amf panel., (d) fuel tank of capacity as per manufacturer recommendations.(e) base frame made out of suitable channel duly reinforced and provided with adequate nu