Tender For corrigendum : repair/ maint of electric fittings & fixtures, building security lights bay light earthing, repair of ceiling /exhuast fan and other misc e/m wks at & repair/ maint of solar water heater, gi tubing, insulation and connected items in madhur milan area & officers md accn, tech area & otm at 13 brd & 16 brd at af stn palam under ge(af) gurgaon no 01
Tender For repair maintenance of of electric sub-station and compound light at gpoa bldg. pushpa bhawan, new delhi. (sh: servicing, overhauling & testing of 11 kv sub-station i/c ht, lt and allied works)
Tender For repair and maint of internal electric supply rewiring switches sockets mcbs dbs light fittings repair and servicing of ceiling fan exhaust fan and geysers
Tender For repair / replacement and maint of lt external electric supply works and other connected items at east & west wing in tech area under ge (af) tech area gwalior - s&f in repair mccb, 4 pole, 630 amps current rating and ultimate breaking capacity ics=icu =100% 36 ka with adjustable overload setting and having thermal magnetic release and to be fixed in distribution board, complete all as specified and directed., all as per item here-in-before but mccb, 4 pole, 400 amps current rating and ultimate breaking capacity 36 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 315 amps current rating and ultimate breaking capacity 36 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 250 amps current rating and ultimate breaking capacity 36 ka. ics = 100% of icu, all as per item here-in-before but mccb, 4 pole, 160 amps current rating and ultimate breaking capacity 36 ka . ics = 100 % of icu, all as per item hereinafter but mccb, 4 pole, 125 amps current rating and ultimate breaking capacity .16 ka . ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 100 amps current rating and ultimate breaking capacity. 16 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 63 amps current rating and ultimate breaking capacity .16 ka . ics = 100 % of icu, m&l for earthing complete with galvanised steel plate electrode 600x600x6mm thick buried directly in ground (top edge of the plate should not be less than 1.50mtrs below ground level) connected to gi strip 25 4mm by means of bolts, nuts check nuts and washers of galvanised iron or steel connected to earthing test point all as specified incl 20 mm gi tubing medium grade and necessary fitting for protection of gi strip incl laying of charcoal dust and common salt in alternate layers of 150mm th, pcc chamber using pcc(1:3:6) type c-1 using 20mm graded stone aggregate, rcc cover 40mm thick (1:2:4) type b-0 using 12.5mm graded stone aggregate reinforced with 6mm dia round bar @ 75mm c/c both ways with ms handle 8mm dia, plastering 15mm thick cm (1:6) externally up to 150mm below ground level, gi funnel with 20mm dia medium grade gi pipe for watering and wire mesh incl excavation and earth work and disposal of surplus soil complete all as specified and shown on electrical plate no.3 of ssr part-i (2009) and connected to earth test point incl testing and marking bldg nos and writing test results (in white) on a black painted m.s. plate (size 300x300x3mm th) duly welded with angle iron of size 40x40x5mm, 60cm long, fixed with the earth pit chamber by grouting complete all as specified and directed.note :- (i) gi strip 25 4mm and gi pipe medium grade, up to 7.5mtr shall be deemed to be included in the rates quoted for earthing.(ii) excavation and earth work in any type of soil strata shall be deemed to be included in rates quoted for earthing. (iii) the rates quoted by the contractor are deemed to be included for pcc chamber and pcc cover as per ssr part-1.-, m&l for preparation of old painted surfaces of lt steel tubular pole/strut, of any description and in any position 9.00/8.50 mtr height and scrapping of pole with emery paper and applying one coat of aluminium paint on all the metallic surfaces including protection pipe, cross arms, clamps, gi pipe bracket of street/security light, anti climbing devices etc and providing three nos radium band strips complete all as specified and directed., supplying ,laying, jointing and testing xlpe insulated, armoured, heavy duty, aluminum conductor cable 1100 volts grade ,laid in trenches/ducts, floors, fixed to walls etc. complete all as specified and directed for the following sizes.note: the cost of taking down of lt ug cable is deemed to be included in the quoted rate, 35 sqmm 3 core, 50 sqmm 3 core, 70 sqmm 3 core, 185 sqmm 3 core, 240 sqmm 3 core, excavation in trenches n exc 1.5 mtr wide and n exc 1.5 mtr depth for foundation and laying of cable and getting out in an
Tender For corrigendum : special repairs to college main gate, provn of work stations and allied works in hq complex and special repair to external electric light fittings at certain location at dssc wellington
Tender For repair repl of intl elct wks incl rewdg of clg fan exh fan w/m fan lt ftgs sub main wirg geyser and oth allied wks incl ot lts at ph i of mh kke repair maint of diesel generator set amf pnls synch pnl and allied wks at mh kke range hls area hq 41 arty div and aund - repair replacement of internal electric works including rewinding of ceiling fan, exhaust fan, wall mounted fan, light fittings, sub main wiring, geyser and other allied works including ot lights at phase-1 of mh khadki including 41 arty div and repair and maintenance of dg set, amf panels, synchronising panel and allied works at mh khadki, range hills area, hq 41 arty div and aundh military complex under ge (mh & rh) khadki
Tender For repair/maint to internal electric supply, fittings, fixture, building security lights, gate light and allied works in akash vihar, 274su, 12afh at af stn gorakhpur under ge(af) gorakhpur.
Tender For repair/maint of internal wiring and external electric supply and street light and repair/maint of ro plant, u/s pipe line, u/s motor and other connected miscellaneous work at ramgarh under ge (af) jaisalmer
Tender For supply of rpl no 10 c c - suppl and fixing of 1 exhaust fan for kitchen room with 15amp socket , supply and fixing of electric wiring in chamber no 02 , supply and fixing of 06 15amp combination board , supply and fixing of 05 led bulb 9 watt , supply and fixing of 01 switch board 10inch x 12inch , supply and fixing of 10 switch 5amp , supply and fixing of 06 socket 5 amp , supply and fixing of 02 security light , replacement of existing 02 ms icon pipe bend of toilet outlet of master cabin toilet of sbs as per existing specification , repair of sea water pipe line of 2hp motor , replacement of existing tapet cover gas kit of main engine of both sides as per existing specification , repair of radiator fan vibrating defect of sbs of main engine , replacement of existing 02 iron battery box as per existing specification including all changes , supply and fixing of 02 exhaust fan of aux engine room , repair of leakage defect of pt pump of sbs and replacement of existing fuel line as per exiting specification