Tender For running maintenance of plc system - running preventive and breakdown maintenance of plc control system with electrical drives all control and instrumentation system of ash handling , replacement new erection of impulse line , replacement new erection of instrument fitting adopter nut tails elbow connector etc , overhauling b 501 and b 601 ss cock valve , overhauling repairing of junction boxes , servicing recalibration erection of fuzi yokogava rosemount etc transmitters , overhauling and recalibration new erection of digital indicators , overhauling and recalibration erection of flow meter conductivity meter , complete overhauling erection of level switches , replacement of pressure switch gauge vibration switch , removal testing erection commissioning calibration of temp gauges switches thermocouple , replacement erection overhauling cleaning of union isolating valveforged body valve , blowing of tapping points of different pressure transmitters switches , fabrication repairing of instruments plateform , laying patrolling of instrumentationcable , servicing and maintenance of air conditioner , cleaning of control room plc system , repairing of ups , service replacement of faulty butterfly valves along with act , servicing replacement of faulty diaphragm type valves , changing spindle gland of root valves , cleaning blowing by air of impulse lines , attend leakage from steam water air line , replace gauges switches of pressure temp , testing caliberation of pressure gauges , testing calibration of pressure switches , testing calibration of temp gauges , testing calibration of temp switches , replacement of thermocouples , cleaning servicing of terminal block in compressor house swas system , changing of ss root valves , servicing of 10mm hp lp 3way manifold valves , replace of 10mm hp lp 3way mfold valves , removal choking replace of impulse line , erection replacement of pvc armored compensate cable , replacement of universal digital indicator , servicing replacement of faulty 4way valve with actuator , replacement remounting of smps 24 v dc , dismantling replacement of combination timerof compressor , servicing of sampling cooler dhx18 sco2 , servicing of sampling cooler dhx12 sco2 , servicing of sampling cooler dhx06 sco1 , miscellaneous mechanical febrication , maintenance of actuator of butterfly valve , maintenance and upkeep of terminal box of motor of actuators in cw pump , maintenance re erection of butterfly valve actuator motor , revisioning and upkeep of marp dcs panel , revisioning testing of various type of switches of local control panel , maintenance revisioning upkeep and testing of 415 v power supply module , maintenance upkeep and repair of junction box of butterfly valve , servicing of mov motors actuators and limit switch assembly , checking cleaning and cable dressing mov motor , overhauling cleaning reconditioning of various size batteries , load test once in six months for various size battery of ups installed for 5x200mw , replacement of damaged switches mcb in acdb panel , cleaning painting of the wooden battery stands , maintenance of window type split type ac , gas charging of ac , rewinding of burnt fan motor
Tender For bid to ras supply of molybdenum heater as per drawing , molybdenum heater holder as per drawing , molybdenum connector heater to heater as per drawing , molybdenum heater to feed through as per drawing , molybdenum heater bracket (with collar) as per drawing , molybdenum heater bracket (without collar) as per drawing , high alumina t insulator as per drawing , molybdenum stud m6x35 with nuts and washer (as per drawing) , molybdenum wire 1.5mm dia x 55mm long (as per drawing) , molybdenum rod 6mm dia x 55 mm long (as per drawing) , molybdenum feed through rod 25mm dia x270mm long x both end m16 thread (as per drawing) , molybdenum m16 nut size 26mm x 26mm x12mm thick(as per drawing)
Tender For bid to ras supply of instrumentationcable, 6 pair x 0.5 sq mm, type-f, unarmoured, individually & overall screened, 0.5 k , instrumentationcable, 8pair x 0.5 sq mm, unarmoured, individually & overall screene , 2x1.5sqmm pair shield typ- g unarmd cable
Tender For corrigendum : supply and installation of telecom and scada equipments for extending data connectivity to upcoming cgd hookups and lmc connectivity in southern region on annual rate contract basis - supply items under arc for telecom system, supply of mpls tp equipment, supply of ip/mpls type switch, supply of converter, ac-dc (230 v ac to 48 v dc), ac-dc (230 v ac to 24 v dc), dc-dc (48 v dc to 24 v dc), dc-dc (24 v dc to 48 v dc), supply of battery charger with battery backup, supply of porta cabin, supply of lct, supply of equipment racks, supply of solar panel with battery back up 300 w, supply of solar panel with battery back up 200 w, supply of solar panel with battery back up 50 w, supply of explosion proof telephone, supply of weatherproof telephone, supply of acoustic half hood booth, supply of multi-paired armoured cable (10 pair), supply of 6 twisted pair, 1.5 sq. mm ( 12 core ), individual pair andoverall aluminium mylar tape shielded with drain wire, supply of 6 twisted pair, 0.50 sq. mm ( 12 core ) individual pair and overall aluminium mylar tape shielded with drain wire, supply of telemetry interface cabinet (tic), supply of analog phones, supply of fxo gateway, supply of fxs gateway, supply of ethernet switch, supply of rtu, supply of mini rtu, supply of ftc, supply of joint closures, supply of ip camera, supply of spares for telecom, supply of spares for rtu, supply of ethernet to serial converter, supply of optical to serial convereter, supply of rs 232 to rs 422/rs485 converter, supply of optical to ethernet converter, supply of out door equipment panel, supply of field mounted enclosure conforming ip-66, supply of gprs modem, supply of atex switch 8 port, supply of 24f ofc cable, supply of rtu management licenses for makes like husky, schneider, etc, telecom system (works), installation of mpls/tp equipment, integration of mpls/tp equipment with existing nms, installation and commissioning of solar system, installation of porta cabin, laying and termination of multi-paired armoured cable (10 pair), installation and configuration of converter/switch and interfacing of same with flow computer and integration with scada system, installation of tic panel, design, engineering and submission of documents, testing of ofc and submission of reports, earthing works, installation testing & commissioning of instrumentationcable, installation commissioning and integration of rtus in existing scada server, installation commissioning and integration of mini rtus in existing scada server, installation and integration of ip cameras in existing server for each cameras, installation of gprs modems if supplied as free issue, extending of leased lines for 1000 km distance including modems (one ethernet interface & one e1 interface for lan) at both ends, rectification of ofc including supply of joint pit with identification of fault and testing of of cable, installation of outdoor panel, transportation charges for free issue material (per km rate to be quoted), laying of ofc through hdd method, laying of ofc through direct trench method, point to point radio communication (2.4/5.8 ghz licence free ism band), laying of ofc cable ( if ofc supplied as free issue by gail), blowing of ofc in duct, manday charges [post-installation manday charges for rtu/telecom works on an on-call basis, including troubleshooting, system calibration, software updates, configuration adjustments, and performance optimization. ], total amount excluding gst, gst (cgst&sgst/utgst or igst) in percentage (%) on net total amount
Tender For bid to ras supply of instrumentationcables : : -two pairs 2p x 0 point 5 0 point 5 sq mm instrumentationcable , four pairs 4p x 0 point 5 0 point 5 sq mm instrumentationcable , eight pairs 8p x 0 point 5 0 point 5 sq mm instrumentationcable , twelve pairs 12p x 0 point 5 0 point 5 sq mm instrumentationcable , two triad 2t x 1 point 5 1 point 5 sq mm instrumentationcable , four triad 4t x 1 point 5 1 point 5 sq mm instrumentationcable