Get complete information related to latest Insulation Tester Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Insulation Tester Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Insulation Tester Tenders.
Tender For corrigendum : supply of various consumable material at emd -1 lighting dept. stps. - flat cable 3 corex4 sqmm with copper conductor for submersible motor, flexible copper wire 1 corex2.5 sqmm (36/0.3 mm)1100v(1 coil is equal to 90 meter), flexible copper wire 1 corex1.5 sqmm (22 / 0.03) voltage grade up tp 1100 volt conf to is- 694, copper cable 2 cx1.5 sqmm, pvc twin wire 2.5mm sqr., self adhesive pvc electric insulation tape rolls with isi mark size 1.80 cm width x 7.5 mtr length x 0.125 mm thickness, of red colour, self adhesive pvc electric insulation tape rolls with isi mark size 1.80 cm width x 7.5 mtr length x 0.125 mm thickness, of yellow colour, self adhesive pvc electric insulation tape rolls with isi mark size 1.80 cm width x 7.5 mtr length x 0.125 mm thickness, of blue colour, self adhesive pvc electric insulation tape rolls with isi mark size 1.80 cm width x 7.5 mtr length x 0.125 mm thickness, of black colour, self adhesive pvc electric insulation tape rolls with isi mark size 1.80 cm width x 7.5 mtr length x 0.125 mm thickness, of green colour, porcelin kit kat fuse 16 amp, porcelain kit kat fuse 63 amp, 415 v , ac, porcelain kit kat fuse 100 amp, 415 v , ac, porcelain kit kat fuse 200 amp, 415 v , ac, din rail mounting channels, ring spanner set model 1812 taparia make, double ended spanner set dep 12, adjustable screw spanner size 8" (200 mm) p.no.1171-8 p, screw driver (tester) taparia product no: 818.special with neon bulb, generally confirming to is 5579-1985 grade - ii, yellow handle,, taparia combination plier, product no.1621-8,210 mm, digital insulationtester, range-0-2000 m-ohm, selectable test voltage-250/500/1000 v dc with rechargeable battery, digital clamp on meter lcd display with backlight, 3-3/4 digit., alluminium ladder self supported a type having 05 feet length, long nose plier insulated with thick c.a. sleeve,165 mm length, taparia make tool, allen key set, product no aki 10, allen key set mm size (09 piece) 1.5,2,2.5,3,4,5,6,8,10 mm, hand drill machine size 13mm, hand grinder machine., aluminium tube terminals10.0 mm2, m.6, aluminium tube terminals16.0 mm2, m6, aluminium tube terminal 35 sqmm,m 8, aluminium tube terminals50.0 mm2, m10, aluminium tube terminals70.0 mm2, m8, aluminium tube terminals95 .0 mm2, m10, pin terminal 1.5 mm2, pin terminal 2.5 mm2, aluminium in line connector25.0 mm2,, 35mm alluminium in line connector als-2"dowell", aluminium in line connector 70 mm2, 95 sqmm crimping alluminium type in-line connectors cat no: hai-15 hex make, crimping tools capacity: 10 mm2 to 185 mm2., crimping tools, capacity: 6 mm2 to 50 mm2., alluminum ring type lug 25 sq. mm, pvc saddle 10 mm, pvc saddle 15 mm, pvc saddle 20 mm, pvc saddle 32 mm, multistrend copper flexible wire 1 core x 4.0 mm2, (7 strendes) pvc (double) insulated, without armourr, 1.1kv grade (100m/coil)
Tender For repair/ maint of lt ug cables and its connected items of masimpur mil stn incl army est at khumbigram under masimpur mil stn - e & m division items, dismantling of old unserviceable/damaged acsr or aac conductors of any size , jumper from overhead line & stacking serviceable & non serviceable material separately complete all as specified and directed., dismantling of old unserviceable/damaged stay assembly embedded in concrete including demolition of pcc and removing unserviceable meterials from site of work complete all as specified and directed., dismantling of cross-arms of ms channel or angle of any sections complete all as specified and directed., dismantling of insulators of any size/type complete all as specified and directed., dismantling earth wire or copper conductor/ cradles/stay /service feeder or distribution span complete all as specified and directed, excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for laying of cable/poles and getting out in soft/loose soil complete all as specified and directed., returning, filling in trenches with soil obtained from excavation including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed., removing excavated materials to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point all all as specified and as directed., supply and laying burnt bricks of sub-class b of size 230mm x 115mm x 75mm laid in trenches for cable protection complete all as specified and as directed, supply and spread dry fine sand in trenches as sand cushioning to under ground cable for protection with fine river sand and provide reqd cover after punning down complete all as specified and directed. note: thickness of sand cushioning after punning down will be measured and paid separately., m&l for cutting existing road / pcc drain for taking out / laying of underground cable and including necessary earth work and making good to match with the existing surface with pcc 1:3:6 type ci using 20mm graded aggregates complete all as specified, taking down or out existing cable of sizes 10 sqmm to 70 sqmm 2/3.5/4 core with cable cover, jointing kit from the trenches / ducts/ along walls / poles / through poles / under roads/ inside sub station including segregation the serviceable cable by cutting down defective portion after testing by meggar (insulationtester ) , stacking and rolling unserviceable cable for further disposal all as directed by engineer in charge. note :(1) excavation / cutting of road or floor/ gi pipe & laying / relaying of cable etc shall be measured and paid seperately under respective item of this schedule, taking down or out existing cable of sizes 95 sqmm to 300 sqmm 3.5 core with cable cover, jointing kit from the trenches / ducts/ along walls / poles / through poles / under roads/ inside sub station including segregation the serviceable cable by cutting down defective portion after testing by meggar (insulationtester ) , stacking and rolling unserviceable cable for further disposal all as directed by engineer in charge. note :-(1) excavation / cutting of road or floor/ gi pipe & laying / relaying of cable etc shall be measured and paid seperately under respective item of this schedule, relaying only serviceable cable obtained from taking out in same or new location or through cable ducts inside sub station of size 10 to 70 sqmm 2/3.5/4 core in trenches / ducts / along walls / poles / under road etc including necessary cable lugs, glands etc complete all as directed and specified. note :- lugs and glands will be measured and paid separately., relaying only serviceable cable obtained from taking out in same or new location or through cable ducts inside sub station of size 95 to 300 sqmm 3.5 core in trenches / ducts / along walls / poles / under road etc including necessary cable lugs, glands etc compl
Tender For repair / maint of split acs 2/1.5 ton , windows acs 2 / 1.5 ton , voltage stablizers and connected items installed at command hospital (wc) and other various location in aor of age e/m ch - servicing of split type ac of capacity 2/ 1.5 tr after disconnecting all incoming and outgoing electric connection, water drain pipe line connection etc. and wash with approved chemical mixed water with the pressure pump, after servicing cleaned all the disturbed area and reassembling the water/electric connection and testing for entire satisfaction of engr-in-charge., all as per item no. 1 here-in-above but window type ac 2/1.5 tr capacity., supplying and charging of refrigerant gas r-22 only after vacuuming dehydration, leak testing of the system as per standard practice testing for proper cooling effects and satisfactory performance complete all as specified and as directed by engr-in-charge for room split/window type ac of capacity 2/1.5 tr., all as per item no: 3 above but gas r-32, all as per item no: 3 above but gas r-410a., all as per item no: 3 above but gas r-134a., taking out defective capacitor of capacity 50+6 mfd after disconnecting all incoming and outgoing electric connection including supply & fix new capacitor on same place and testing complete all as specified and as directed by engr-in-charge, all as per item no:7 here in above but of capacity 45+4 mfd ., all as per item no:7 here in above but of capacity 45 mfd ., all as per item no: 7 here in above but of capacity 6 mfd ., all as per item no: 7 here in above but of capacity 4 mfd ., supply & fixing as in replacement copper pipe 1/2" for liquid line including fittings and testing complete all as specified and as directed by engr-in-charge., supply & fixing as in replacement copper pipe 1/4" for liquid line including fittings and testing complete all as specified and as directed by engr-in-charge., supply & fixing as in replacement copper pipe 5/8" for liquid line including fittings and testing complete all as specified and as directed by engr-in-charge., supply & fixing as in replacement copper pipe 3/8" for liquid line including fittings and testing complete all as specified and as directed by engr-in-charge., supply and fixing of insulation foam for copper pipe of size 1/2" after removing old one., supply and fixing of insulation foam for copper pipe of size 1/4" after removing old one., supply and fixing of insulation foam for copper pipe of size 5/8" after removing old one., supply and fixing of insulation foam for copper pipe of size 3/8" after removing old one., supply and fixing as in replacement of pvc flexible pipe 15 mm dia including any fittings as required complete inclusive of any type of leakage testing., all as per item no: 20 above but pipe of 20 mm dia., supply and fixing as in replacement of pvc water drain pipe 25 mm dia complete inclusive all fittings and any type of leakage testing., material and labour for sub main wiring with 2 x 2.5 sqmm +1 x 2.5 sqmm single core flame retardant pvc insulated unsheathed cable with stranded copper conductor drawn in and including heavy grade frlsh pvc concealed conduit isi marked with all accessories on walls and making good the disturbed surfaces including all conduits fittings, clamps guittes etc for earth dbs and boxes with proper thimbles all as directed by engr-in-charge. note :02 run of 2.5 sqmm , 01 run of 2.5 sqmm cable and 01 run of conduit shall be measured as one unit and paid accordingly., all as per item no: 23 here in above but of size 2x 4 sqmm +1x 4 sqmm., m&l cutting chases, pinning in stone concrete block or slab walls & making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring ,etc., and making good, cutting exc. 10 cm girth., supply and fix as in replacement of rigid non-metallic pvc conduit of size 20
Tender For corrigendum : supply of digital dc insulationtester (meggar) , digital micro ohm meter , digital winding resistance ohm meter , automatic 3-ph transformer turns ratio tester , portable cable fault locator , portable earthing resistance measuring device
Tender For supply of digital high voltage insulationtester . test voltage 250v to 5 kv insulation resistance measurement range up to 1 tera ohm with polarization index (pi) and di electrical absorption rate (dar) testing facility , make: fluke/flair/teams or similar. [ warranty period: 30 months after the date of delivery ]]
Tender For ame for supply of electrical materials to ttd kms in ananthapur dist of pertaining to esd-west, tirupati for the year 2026-27 - (7 to 9)w led, (8 +12) 4 way tpn db horizontal with ip 43, 12 nos, 0.5w led, 1 or 2 modular cover frame., 100 a to 160 a, 100a fp, 12 / 15 ms plain rod fan hook, 12 modular vertical cover frame., 12 way spn db with ip 43, dp incomer-1 no, sp mcbs -10 nos, 125a, 150 sqmmx 3.5 core, 16 sqmmx 4 core, 16a / 20a 1 way 1 module modular switch., 16a flush type socket with shutter, 16a flush type swich., 2.0 kw, 200a, 20a modular socket with shutter, 25 sqmmx 3.5 core, 250a to 350a, 3 core 2.5 sqmm, 3 core 4.0 sqmm, 3 modular cover frame., 3.0 kw, 36/0.3mm (2.5 sqmm), 4 core, 16 sq mm, 4 core, 2.5 sq mm, 4 core, 4.0 sq mm, 4 core, 6 sq mm, 4.0 sqmm, 400a, 40-63a dp mcb, 40-63a sp mcb, 40-63a, fp mcb, 40a 2 pole,30ma, 40a, 2 pole,100ma, 40a, 4 pole ,100ma, 5.0w led, 50 sqmmx 3.5 core, 56/0.3mm (4.0 sqmm), 6-32a dp mcb, 6-32a sp mcb, 6-32a, fp mcb, 63a fp, 63a, 2 pole,100ma, 63a, 4 pole,100ma, 6a / 10a 1 way 1 module modular switch., 6a / 10a 3/2 pin 2 module modular socket with shutter., 6a 1 way flush type swich., 6a 3/2 pin flush type socket with shutter., 6a triangle plug top of, 70 sqmmx 3.5 core, 8 modular horizontal / vertical cover frame., 84/0.3mm (6.0 sqmm), one module pvc blanking plate, stepped type electronic regulator, supply and fixing of anchor fastner with fan hook / providing ms fan hook with grouting and cement plastering, supply and fixing of isi marked ( is:4159) marked copper sheathed,nickle plated, mineral filled heating element including making connection testing etc as required, supply and transportation of following xlpe insulated, 1100v grade armoured alluminium cable as per specification confirming to is:7098 (part - i)./1554-i makes: torent / universal / unicab / havells / kei / gloster / polycab /rr kabel, supply of ,??... 10ka c/d curve isi mark. makes: legrand-dx3 / schneider-acti9/hager-h3/ siemens-5sx4/ crabtreexpro/l&t-au/indo asian-opti pro, supply of . lamp with input voltage 90 to 300v, colour temparature 3000k - 6500k, beam angle 170- 220 degrees, b22 base. makes: phillips/crompton/ bajaj/havells / halonix/gm/hplsyska/green lites/ fortune art / goldmedal /r led/luker/leo/orbit, supply of ?...pvc insulated and sheathed frls copper round cable for voltage up to 1100v as per is 694/1990. makes: finolex / rr kabel / havells /kei/polycab/gloster, supply of ?? category- i makes:legrand(myrius /lyncus)/ schneider(clipsal x/ livia ab)/ crabtree (murano/athena) / lauritz knudsen-englaze (formerly l&t)/ gm-(four-five)/ goldmedal(gifa)/million (m-vee)/anchor (roma plus) /precision (series7) / honeywell(blenzepro), supply of ??. 4 pole change over switch on load with open execution as per is:13947 makes: socomec / l & t / hpl / havells/ c&s, supply of ??... isolator. makes: legrand-dx3 / schneider-acti9/hager-h3/ siemens-5sx4/ crabtreexpro/l&t-au/indo asian-opti pro, supply of ??..hrc fuse links as per is 13703-part 2/iec 60269- part 2 makes: l & t / g e / c & s / standard / hpl / havells / siemens / indo asian, supply of ???.. rccb for earth leakage protection. makes: legrand-dx3 / schneider-acti9/hager-h3/ siemens-5sx4/ crabtreexpro/l&t-au/indo asian-opti pro, supply of ????. protection suitable for ????. s.p outgoings and for 1 no incomer etc., complete as per is 8623; is 13032; iec 61439-3. category- i makes: legrand(ekinox 3) / schneider-a9/hager -novello+/ seimens/havells stadx/ lauritz knudsen (formerly l&t)-newrange/indo asian-opti pro/ hpl (techno)/ anchor (uno plus), supply of ????.. makes: legrand arteor / schneider zen celo/ crabtree murano or amare/l&tenglaze/ gm-zenova/ goldmedal(gifa), supply of ??????... protection suitable for installation of ???of sp outgoing mcbs and for 1 no 4 pole, mcb/isolator incomer along with provision for 1 no of 4 pole rccb/elcb etc., complete as per is 8623; is 13032; iec 61439-3. category- i makes: l