Tender For supply installation & commission of tss (terminal support system) & datacom equipment under crew management system for crew and guard lobby et,rkmp,bina.05 kiosk lobby terminal support system (tss) equipment with integrated breath analyzer, biometric and camera device according to cris specification no. no.2007/cris/ndls-hq/cms/project / rollout - ii / 0030 / pt -ii, dated 26.07.2024 or latest attached. (remark - 01 number to be delivered at crew and guard lobby et,03 number to be delivered at crew and guard lobby bpl, & 01 number to be delivered at crew and guard lobby bina.) [ warranty period:30 months after the date of delivery ] ]
Tender For consultancy work of civil work like rcc trimix road, asphalt road, paver block road, footpath, divider, traffic circle, street light, all type of building like community hall, party plot, complex, library building , gymnasium building, crematorium development, new garden development, beautification, solar power system, cctv camera, water supply, underground drainage, strom water drain, solid waste management etc. development related project work for various scheme
Tender For provision of new led street lights with allied accessories on existing poles at various dark spots in saidulajab ward no 160 under south zone - led street light fixture, powder coated pressure die cast aluminium body (system lumen efficacy >135 lm/watt). supplying, installation, testing & commissioning of street light led fixture, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with driver efficiency >85%, input voltage: 140-270 volt ac, frequency 50/60 hz, operating temp range -5 0c to 50 0c, internal surge protection of 5 kv l,n,e as per iec 61000-4-5, driver efficiency >85%,thd 10% as per iec 61000-3-2, p. f. 0.95, ip-66,ik-10, cri >70, under voltage and over voltage protection, emi-emc as per cispr-15, lenses for beam angle as per iesna type i/ii/iii as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (led,driver & electrical circuitary) of minimum 50000 burning hours with 70% of initial lumen maintained till life ends as per lm80 extrapolation ies tm-21-11 report, cct 3000 k / 4000 k / 5700 k /6500 k (as per ansi bin), sdcm(standard deviation color matching)5, maximum power consumption should not more than the specified rating and fixture shallbe of relevant bis standard complete in all respect i/c external connections with 1.5 sq mm frls/hffr, pvc insulated copper conductorsingle core cable and earthing etc. as required withminimum 5 year oem warranty. system lumen efficacy >135 lm/watt output . lm79 & lm80 testreport and all testing required for led fixturesas per bis shall be submitted.. shape size and cct shall be as approved by engineer-in-charge asper requirement. (thermal management: heat sink of aluminium housing such that led junction temperature shall not rise above 90 c). 45 watt , supply and fixing of 32mm dia x 1 meter long g.i. pipe (medium class) bracket for mounting of fluorescent/hpmv/hpsv street light fitting on pole including bending the pipe to the required shape , 2 nos 25mm x 6mm flat iron clamps with nuts, bolts and washer , painting the flat iron with primer and finish paint etc. as reqd, supplying and drawing following sizes of frls pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required. 3 x 1.5 sq. mm, supply of xlpe insulated pvc sheathed al. conductor un-armoured cable 1.1kv grade conforming to is-7098 of following size:-2c*4 sqmm, laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size in the existing masonry open duct as required. upto 35 sq. mm
Tender For provision of led light fittings with accessories at various locations in ward no. 167 khanpur, under south zone. - supplying and drawing following sizes of frls pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required. 3 x 1.5 sq. mm, supply and fixing of 32mm dia x 1 meter long g.i. pipe (medium class) bracket for mounting of fluorescent/hpmv/hpsv street light fitting on pole including bending the pipe to the required shape , 2 nos 25mm x 6mm flat iron clamps with nuts, bolts and washer , painting the flat iron with primer and finish paint etc. as reqd., supply of xlpe insulated pvc sheathed al. conductor un-armoured cable 1.1kv grade conforming to is-7098 of following size:-2c*4 sqmm, laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size in the existing masonry open duct as required. upto 35 sq. mm, led street light fixture, powder coated pressure die cast aluminum body (system lumen efficacy 135 lm/watt) supplying, installation, testing & commissioning of street light led fixture, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with driver efficiency >85%, input voltage: 140-270 volt ac, freq 50/60 hz, operating temp range -5 deg centigrade to 50 deg centigrade, internal surge protection of 5 kv l,n,e as per iec 61000-45, driver efficiency >85%,thd 10% as per iec 61000-3-2 , p. f. 0.95, ip66,ik-10, cri 70 , under voltage and over voltage protection,emi-emc as per cispr-15, lenses for beam angle as per iesna type i/ii/iii as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (led,driver & electrical circuitry) of minimum 50000 burning hours with 70% of initial lumen maintained till life ends as per lm80 extrapolation ies tm-21-11 report , cct 3000 k / 4000 k / 5700 k /6500 k (as per ansi bin) , sdcm(standard deviation color matching) 5, maximum power consumption should not more than the specified rating and fixture shall be of relevant bis standard complete in all respect i/c external connections with 1.5 sq mm frls/hffr, pvc insulated copper conductor single core cable and earthing etc. as required with minimum 5 year oem warranty. system lumen efficacy 135 lm/watt output . lm79 & lm80 test report and all testing required for led fixtures as per bis shall be submitted. shape size and cct shall be as approved by engineer-in-charge as per requirement. (thermal management: heat sink of aluminum housing such that led junction temperature shall not rise above 90 c). 45 watt
Tender For construction of pressurized pipe system to supply water for solar micro irrigation to deliver at farmers field up to 1 ha with a duty of 0.84 lit/sec/ha and maintained up to 4 ha chak, keeping the discharge of minimum 3 times the duty at one hectare and at least 20 meter residual head at 1 ha for micro pressurized irrigation in distt. bilaspur in 135 ha. in kharif ( left side of bhaisajhar lift irrigation scheme. as indicated in index map), out of total gross command area, 135 hectare fully covering the entire compact, contiguous possible arable area beyond 500m from submergence line (ftl line) of bhaisajhar lift irrigation scheme as indicated in the index map for micro irrigation system without exceeding total power requirement for solar pumps with solar panel it includes all activities starting from investigation , planning ,design, drawing, construction of underground distribution network for micro irrigation system down to 1 ha chak in 8 ha consisting of providing, laying & fixing of all types of pressurized pipe lines with all necessary valves to serve as main line, branch line, distributaries, minors and sub-minors of pressurized irrigation system of bhishajhar lift irrigation project (to serve total cca not less than 135 ha in kharif ) including providing control at 4 ha and 2 ha with fixing multiple outlets with duty of 0.84 lit/sec/ha upto 4 ha and distribution network up to 1 ha chak, to serves the area as shown in index map with discharge of 3 times the specified duty at 1 ha chak including scada & successful trial run and commissioning and as per scope work and as directed by engineer-in-charge.. the work also includes formation of fpo as per company act/rule, management, operation and maintenance (mom) and defect liability (dl) for the period of 05 years after completion and mom and dl period run simultaneously and work also including foundation stone laying ceremony and inauguration ceremony and as directed by engineer-in-charge as per details given in scope of work. mou between agency and fpo to operate scheme after 05 years of mom and dl period and to arrange linkage facility to the fpo
Tender For engagement of project management consultant (pmc) for providing mep like high and low side electrical, hvac, fire protection system, lifts, fire alarm and public address system and plumbing works ,facade with lighting and interiors in integrated andhra pradesh state secretariat and hod offices (gad tower,tower 1 and 2,tower 3 and 4) in amaravati government complex, andhra pradesh)
Tender For providing of hiring of consultancy services - percentage based - expansion of intelligent traffic management system itms to all remaining traffic junction in chandigarh; it project management; yes; hybrid(as specified in scope of work)
Tender For consultancy work of civil work like rcc trimix road, asphalt road, paver block road, footpath, divider, traffic circle, street light, all type of building like community hall, party plot, complex, library building , gymnasium building, crematorium development, new garden development, beautification, solar power system, cctv camera, water supply, underground drainage, strom water drain, solid waste management etc. development related project work for various scheme.
Tender For supply of four lane flap or swing barriers including one wider lane , client pc with server , face terminal , access bracket , sixteen port poe switch , tcp ip based smart access controller 4 door , central management software , installation and commissioning charges , deinstallation and buy back , concealed cabling work of total system , power supply , enclosures for controllers , 4 u wall mount rack , cost of civil works involved in the project , comprehensive amc charges for second year , comprehensive amc charges for third year , comprehensive amc charges for fourth year , comprehensive amc charges for fifth year , comprehensive amc charges for sixth year