Tender For tender for work of erection of bay equipment, cr panel, control wiring, earthing etc at 66kv varahi sub-station under deodar division of palanpur circle
Tender For work of erection of 66kv equipment, structures, control wiring, yard lighting, control-room & electrification etc. for 2x15mva, 66/11kv rampara sub-station.
Tender For ttps es circle mrt ii blowing cycle operation trouble shooting of water wall soot blowers lr soot blowers cleaning maintenance of control panels junction boxes field equipment of fsss boiler auxiliaries systems in units iv v sub division iii
Tender For construction of control room building ,providing foundation concrete structure, equipment plinth, plinth for breaker, transformer plinth, cable duct and other civil related works for the establishment of 110 kv ss at edaicode
Tender For corrigendum : providing of tentage service lumpsum based - venue preparation for conduct of veterans officers forum lunch on 04 jan 26; floorings, lighting, air conditioning, tent rentals, theme based installation, decoration, furniture & equipment rentals, climate control, po..
Tender For supply of visualizer , projector with projector screen , networking switchine control equipment and matrix wwitcher , podium , biometric system
Tender For supply of procurement of dtmf way station control equipment 4 wire with telephone%u201d as per specification no. irs:tc:60-2007 with latest amendments etc.
Tender For corrigendum : tender for supply of laboratory equipments andinstruments - machinery & equipment, hplc module pump(quaternary gradient) high precision dual plunger design. system designed to work in micro , semi-micro analytical to semi prep scale high speed double micro plunger in parallel pump with automatic pulsation correction mechanism achieving pulse free solvent delivery forced check valve designed for excellent solvent delivery control flow raterange:0.0001ml to 10.0ml/min each pump flow rate resolution of 3nl/step increment built in self diagnostic, auto purge function flow precision is less than 0.06% rsd flow rate accuracy: 1% concentration accuracy 0.5%washing kitgradient mixer,reservoir trayquaternary gradient unitdgu-20a5r bkl degassing unitmanual injector: rheodyne injector with 20 ul loop & mounting plate 25ul hamilton syringepda detectorwavelength 190 800 nm, channel 512, drift smaller than 0.5x10-3 au/hour, noise smaller than 0.6x10-5 au. wavelength accuracy should be 1 nm, linearity: 2.0au or more. a deuterium lamp [d2] and a tungsten lamp [w] should be available as light source a conventional hplc flow cell [12 l volume, 10 mm cell path length]. lamp replacement: front access, lamp life time : 2000 hours (d2 lamp)controller alite system controller, solvent bottles with cap 5/pkt, chromatographic software