Tender For corrigendum : tender for the supply of various equipments - muffle furnace, "al2o3 sample plate, al2o3 furnace door block, protection glove, crucible clip, crucibles, karlfischer titrator, "titration vessel, detector electrode with lead, generator electrode (with frit) with lead, desiccant tube and cap, injection septa (pack of 10), gas tight syringe 1.0ml , luer needle 17-gauge, dust cover, results manager software, main power pack, fuse, karlfischertitration reagent(s), nist calibration standard, refrigerated centrifuge (bench top), bottles/falcon tubes/adapters for 0.2ml tubes, one set of other items (adapters) required for improving the applicability/system performance should to be quoted, nitrogen evaporator, evaporation tubes, gas fuse , water purification system including water softner, cartridges, filters etc. for , bomb calorimeter, "ignition wire, cotton thread, combustion crucible, bomb, nist certified benzoic for calibration, any other accessories required for analysis of food samples., gas chromatograph with ecd, tcd, fid with autosampler, "pesticide column (30 m x 0.250mm x 0.25m (5ms (95% dimethyl-, 5% diphenyl-polysiloxane / 1ms (100% dimethyl polysiloxane or equivalent) 100 mm column for fatty acid profiling with main concern of trans fatty acid application, column for cholesterol application, stationary phase: 95% dimethyl-, 5% diphenyl-polysiloxane (30 m x 0.250mm x 0.25m),, "vial sets (1, 2 ml, crimp type, amber and clear glass), vials (10, 20ml crimp type with cap & septa), 300/500 l recovery vials, septa ptfe/silicone (for 1, 2 ml vials), septa ptfe/silicone (for 10, 20 ml headspace vials), ergonomic crimping tools for different vial types, ergonomic decapping tools for different vial types, head space vials 10,20 ml capacity, suitable syringes for quoted autosampler, suitable headspace syringe /valve/loop, quechers kits for pesticides and herbicides in following matrices:, matrices with high fat, matrices with high water content, matrices with high pigmented, spe cartridges for water., ultra performance liquid chromatography (uplc) with photodiode array (pda), fluorescence (fld) and refractive index detector (rid), sample vials with 1.5 ml or greater, stainless steel ultra sonic bath with the capacity of 5 l or more, with time setting (min) 1-30min or continuous operation with led and push button (should be ip 33 protection class) for sonication of spare parts as well as solvents, fittings, frits, ferules and tubings, tubing cutter, solvent bottles (1000 ml capacity), solvent filters (glass & ss both, compatible manual syringes -10 l, 20 l, 50 l, standards for hplc calibration for pda, ri and fluorescence detector, consumables required for each detector must be provided., "hplc columns: one each of, c8 = 250 4.6 5m c18 = 250 4.6 5m, cyano = 250 4.6 5m. amino = 250 4.6 5m, phenyl = 250 4.6 5m. silica = 250 4.6 5m., all columns must be supplied with respective guard column and holder. ", uv-visible spectrophotometer, ",0.5, 1 and 3-ml quartz cuvettes 10 mm path length, 0.5, 1, and 3 ml glass cuvettes 10 mm path length, cuvette holder, suitable certified standards for validation including holmium oxide glass filters for wavelength calibration & nist traceable, nist traceable potassium dichromate., uv-visible spectrophotometer, ",0.5, 1 and 3-ml quartz cuvettes 10 mm path length, 0.5, 1, and 3 ml glass cuvettes 10 mm path length, cuvette holder, suitable certified standards for validation including holmium oxide glass filters for wavelength calibration & nist traceable, nist traceable potassium dichromate., ft-ir with atr & liquid cell, " hydraulic press with kbr die and pellet holder, suitable mortar pestle (dia 5-6 cm), suitable portable de humidifier to maintain 30- 60% rh, temperature and relative humidity digital indicator with calibration certificate from iso 17025 accredited lab., reference nist standard polystyrene film (0.3 mm) over the range of 3800 cm-1 to 650 cm-1., abbes r
Tender For supply of combimethanol solvent for volumetric karlfischer , buffer solution for strong acids for karlfischertitration as per tech spec annx attached , imidazole , combititrant 5 as per tech spec annx attached
Tender For purchase of 1. hydranal water standard 0.1 cat no 34847 (honeywell) 1pack (40 ml). 2. supelco product no. 1.88055.0010 aquastar water standard oil certified reference material for karlfischertitration (oil matrix 15-30 ppm h2o) 1 pack (80 ml) for odtl lab under protection & os division. pstcl. ludhiana.
Tender For supply of lab equipment - "sieve shaker-gyratory-for 20/30 & 45cm dia sieves with digital timer, , sieve shaker carries upto 7 sieves of 450mm diameter in single adaptor. supplied without sieves or lidpan. detailed specification as follows:, calibration from nabl lab shall be included", "sieve shaker-gyratory-for 20 & 30cm dia sieves with digital timer-, sieve shaker carries upto 7 sieves of 200 / 300 mm diameter in single adaptor. supplied without sieves or lidpan. detailed specification as follows:, calibration from nabl lab shall be included", "sieve shaker-gyratory-for 20cm dia sieves with digital timer, sieve shaker carries upto 7 sieves of 200mm diameter in single adaptor. supplied without sieves or lidpan. detailed specification as follows:, calibration from nabl lab shall be included", "pavement core drilling machine with petrol engine - 5.5 hp and 100mm dia core drill bit, the machine is primarily intended to drill out core samples from the asphalt or concrete road, suitable for vertical drilling only. detailed specification as mention in following page. supplied with 100 mm dia x 450 mm / 400 mm core drill bit. ", "core drill bit 65 mm, 70 mm , 100mm and 150 mm dia x 450mm with barrel - v,, with portable pump / portable submersible pump", "core cutting machine - 150 mm dia core -with accessories , rock/stone/concrete cube or cylinder cutting and grinding machine, with 450mm dia diamond impregnated cutting wheel, suitable to cut up to 150mm depth. equipped with 2 hp three phase electric motor, starter. floor standing model. water tank of 25 ltr. below machine level.", "bitumen extractor - motorised with variable speed with digital rpm indicator, special model with ac motor and drive : this model facilitates precise speed control and vibration free smooth operation. speed variation up to 3600 rpm. complies with following international standards - astm d 2172, aashto t 58, t 164. , calibration from nabl lab shall be included", "buoyancy balance with electronic balance - 15 kg x 0.1 gm, for water absorption and specific gravity test of aggregates. with density basket, water tight cylinder and electronic balance of 15 kg x 0.1 gm sensitivity. the balance will be with under hook weighing arrangement and will be mounted on suitable table to facilitate the test. the water tight container will be mounted on a mechanical jack, which will facilitate the updown movement of the container for weight in air and water. as per en 12390-7, bs 1881:114, is:2386 (part iii) , calibration from nabl lab shall be included", "rebar locator - profometer pm8000, profometer pm8000 - portable concrete rebar locator - the latest generation 2023 product release by screening eagle switzerland, under its value brand proceq, is the most powerful & precise instrument for inspection of concrete for locating reinforcement bars, their position, spacing, cover & diameter of rebar, fully wireless designed for use in rough environments. profometer pm 8000 with i pad basic model", "reaction container - is 2386 (part vii),, as per is:2386 -part vii (fig.5), made of stainless steel, 50 to 75 ml. capacity, fitted with air tight cover.", "refractory furnace-9"" x 4"" x 4""-1200c,, light weight with ceramic wool insulation. the outer casing made of thick mild steel sheets painted attractively. heating chamber consist of grooved refractory bricks in which heating elements are inserted in coil form and are easily replaceable. temperature controlled by dual display microprocessor based digital temperature indicator cum controller with k type sensor. compensating cable etc.working on 230 v. max. temperature: 1200 c. & working temp.: 1150 c. detailed specification as follows:, calibration from nabl lab shall be included", "chloride meter for fresh concrete (germann instrument make), the chloride meter has the best performance to quickly and accurately measure the chloride ion concentration contained in raw concrete/aggregate. all equipment required
Tender For corrigendum : tender for the supply of various equipments required for upgradation of district food laborartory, karnal - muffle furnace, "al2o3 sample plate, al2o3 furnace door block, protection glove, crucible clip, crucibles", karlfischer titrator, "titration vessel, detector electrode with lead, generator electrode (with frit) with lead, desiccant tube and cap, injection septa (pack of 10), gas tight syringe 1.0ml , luer needle 17-gauge, dust cover, results manager software, main power pack, fuse, karlfischertitration reagent(s), nist calibration standard", refrigerated centrifuge (bench top),, bottles/falcon tubes/adapters for 0.2ml tubes, one set of other items (adapters) required for improving the applicability/system performance should to be quoted, nitrogen evaporator, evaporation tubes, gas fuse , water purification system including water softner, cartridges, filters etc. for , bomb calorimeter, "ignition wire, cotton thread, combustion crucible, bomb, nist certified benzoic for calibration, any other accessories required for analysis of food samples.", gas chromatograph with ecd, tcd, fid with autosampler, "pesticide column (30 m x 0.250mm x 0.25µm (5ms (95% dimethyl-, 5% diphenyl-polysiloxane / 1ms (100% dimethyl polysiloxane or equivalent) 100 mm column for fatty acid profiling with main concern of trans fatty acid application, column for cholesterol application, stationary phase: 95% dimethyl-, 5% diphenyl-polysiloxane (30 m x 0.250mm x 0.25µm),", "vial sets (1, 2 ml, crimp type, amber and clear glass), vials (10, 20ml crimp type with cap & septa), 300/500 µl recovery vials, septa ptfe/silicone (for 1, 2 ml vials), septa ptfe/silicone (for 10, 20 ml headspace vials), ergonomic crimping tools for different vial types, ergonomic decapping tools for different vial types, head space vials 10,20 ml capacity, suitable syringes for quoted autosampler, suitable headspace syringe /valve/loop, quechers kits for pesticides and herbicides in following matrices:matrices with high fat, matrices with high water content, matrices with high pigmented, spe cartridges for water.", ultra performance liquid chromatography (uplc) with photodiode array (pda), fluorescence (fld) and refractive index detector (rid), sample vials with 1.5 ml or greater, stainless steel ultra sonic bath with the capacity of 5 l or more, with time setting (min) 1-30min or continuous operation with led and push button (should be ip 33 protection class) for sonication of spare parts as well as solvents, fittings, frits, ferules and tubing’s, tubing cutter, solvent bottles (1000 ml capacity), solvent filters (glass & ss both, compatible manual syringes -10 µl, 20 µl, 50 µl, standards for hplc calibration for pda, ri and fluorescence detector, consumables required for each detector must be provided., "hplc columns: one each ofc8 = 250 × 4.6 × 5μm c18 = 250 × 4.6 × 5μmcyano = 250 × 4.6 ×5μm. amino = 250 × 4.6 × 5μmphenyl = 250 × 4.6 ×5μm. silica = 250 × 4.6 × 5μm.all columns must be supplied with respective guard column and holder. ", uv-visible spectrophotometer, ",0.5, 1 and 3-ml quartz cuvettes 10 mm path length, 0.5, 1, and 3 ml glass cuvettes 10 mm path length, cuvette holder, suitable certified standards for validation including holmium oxide glass filters for wavelength calibration & nist traceable, nist traceable potassium dichromate.", uv-visible spectrophotometer, ",0.5, 1 and 3-ml quartz cuvettes 10 mm path length, 0.5, 1, and 3 ml glass cuvettes 10 mm path length, cuvette holder, suitable certified standards for validation including holmium oxide glass filters for wavelength calibration & nist traceable, nist traceable potassium dichromate.", ft-ir with atr & liquid cell, "• hydraulic press with kbr die and pellet holder• suitable mortar pestle (dia 5-6 cm)• suitable portable de humidifier to maintain 30- 60% rh• temperature and relative humidity digital indicator with calibration certificate from iso 17025 accredited lab.• ref