Get complete information related to latest Lead Joint Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Lead Joint Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Lead Joint Tenders.
Tender For corrigendum : fibre glass 3 section telescopic operating rod with earthing conductor (lead) and continuous pole height adjustment, locking mechanism having total extension length of 6 meters
Tender For supply of vital sign monitors , ecg 5 lead set cable with each monitor prices would be frozen during warranty and cmc , ecg extension trunk cord with each monitor prices would be frozen during warranty and cmc , spo2 probe for adult finger with each monitor prices would be frozen during warranty and cmc , spo2 pediatric probe with each monitor prices would be frozen during warranty and cmc , nibp cuff adult size with each monitor prices would be frozen during warranty and cmc , nibp cuff paediatric with each monitor prices would be frozen during warranty and cmc , spo2 interface cable with each monitor prices would be frozen during warranty and cmc , nibp hose pipe with each monitor prices would be frozen during warranty and cmc , temperatures probes skin with each monitor prices would be frozen during warranty and cmc , etco2 module prices would be frozen during warranty and cmc , disposable airway adapter prices would be frozen during warranty and cmc , reusable interface cable for ibp monitoring for two monitors only prices would be frozen during warranty and cmc , disposable transducers for two monitors prices would be frozen during warranty and cmc , rechargeable battery pack with each monitor prices would be frozen during warranty and cmc , wall mount with each monitor , cmc for 1st year , cmc for 2nd year , cmc for 3rd year , cmc for 4th year , cmc for 5th year , cmc for 6th year , cmc for 7th year , cmc for 8th year
Tender For cleaning swd manhole complete including disposal of malba within 5 km lead complete in all respect as per satisfaction of eic at sector 27 (part-ii), panchkula extension (a/mtc of ph services in sector 23 to 28, 31 and 32 and sector 1 to 6, mdc, panc
Tender For cleaning sewerage manhole / line complete including disposal of malba within 5 km lead complete in all respect as per satisfaction of eic at sector 25, panchkula extension (a/mtc of ph services in sector 23 to 28, 31 and 32 and sector 1 to 6, mdc, pa
Tender For cleaning swd manhole complete including disposal of malba within 5 km lead complete in all respect as per satisfaction of eic at sector 32, panchkula extension (a/mtc of ph services in sector 23 to 28, 31 and 32 and sector 1 to 6, mdc, panchkula)
Tender For cleaning swd manhole complete including disposal of malba within 5 km lead complete in all respect as per satisfaction of eic at sector 28 (part-i), panchkula extension (a/mtc of ph services in sector 23 to 28, 31 and 32 and sector 1 to 6, mdc, panch
Tender For certain repairs to water supply distribution lines and other connected items at zone c at mil stn bhuj and gandhidham under ge(a) bhuj - taking up u/s ac/gi/di/upvc water main (incl all fitting) with spigot & socket /ms pipe or any other type of pipe or leadjoint incl burning out joint & recovering lead from pipe of 200 mm bore for laying /rerouting of serviceable pipe after cleaning complete all as specified and directed., all as per item 1 above but 150 mm dia bore complete all as specified and directed., all as per item 1 above but 100 mm dia bore complete all as specified and directed., all as per item 1 above but 80 mm dia bore complete all as specified and directed., all as per item 1 above but 50 mm dia bore complete all as specified and directed., material and labour di pipes of size 200 mm bore with spigot and socket end centrifugally cast class "k- 7" , in any length laid in trenches/on surface/ over masonary pillar and connection to old or new position complete all as specified and directed., material and labour di pipes of size 150 mm bore with spigot and socket end centrifugally cast class "k- 7" , in any length laid in trenches/on surface/ over masonary pillar and connection to old or new position complete all as specified and directed. note: di fitting /leadjoint / tyton joint will be measured and paid seperately all the dismanted / demolished /taking down material shall be reused or removed from site., all as per item 7 above but 100 mm dia bore complete all as specified and directed., supply and fixing in any length upvc pipe 150 mm dia pipe manufactured as per astm-d-1785 as per is-559, schedule-40 complete with fittings, laid in trenches in required length complete all as specified and directed., all as per item 9 above but 100 mm dia bore complete all as specified and directed., all as per item 9 above but 80 mm dia bore complete all as specified and directed., all as per item 9 above but 50 mm dia bore complete all as specified and directed., m&l di bend any type radius and angle tapers any type straght bend increacing decreacing or double socket etc) tee pipe single branch y juction double branch cross(all socket and spiogat collars caps and plug for the pipe socket & spiogat of pipe size upto 200 mm dia complete all as specified and directed. ( lead /gasket for fitting shall be measured and paid separately), s & f in repair upvc ball valves with operating handle (stop valve) of size 50 mm dia complete suitable for fittings with astm - 1785, schedule 40 upvc pipes complete all as specified and directed., s & f in repair upvc ball valves with operating handle (stop valve) of size 80 mm dia complete suitable for fittings with astm - 1785, schedule 40 upvc pipes complete all as specified and directed., excavation in trenches in soft / loose soil nexc 1.5 mtr wide and not exc 1.5 m in depth etc complete and getting out in soft soil inciuding trimming sides and bottom of trenches complete all as specified and directed., rentring filling in trenches including watering and well ramming in layer not exc 25 cm thick in soft/ loose soil complete all as specified and directed., removing excavated surplus soil to a distance not exc 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed., hard standing cutting/road cutting for laying of pipe and making surface good with pcc 1:3:6 complete all as specified and directed., taking down carefully cast iron sluice valve of size 80 mm to 200 mm bore from ci water mains, complete with all acessories complete all as specified and directed., s&f in repair sluice valves flanged end, cast iron body, flanged and drilled and non rising type stainless steel spindle with nut, long body, class p n 1.6, conforing to is 14846 of 2000 for following sizes including all flange joint with rubber or fiber board, bolts, nuts and washers complete including pumping out accumulated water