Get complete information related to latest Level Control Valve Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Level Control Valve Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Level Control Valve Tenders.
Tender For tender for supply of controlvalves - fuel oil flow controlvalve as per boq line item 1 , pyrolysis fuel oil flow controlvalve as per boq line item 2 , fuel gas flow controlvalve as per boq line item 3 , spray controlvalves as per boq line item 4 , steam to sb pressure controlvalve as per boq line item 5 , cbd levelcontrolvalve as per boq line item 6 , atom steam pres cont valve as per boq line item 7 , mandatory spares as per boq line item 8 , commissioning spares as per boq line item 9
Tender For instrument spare and annual maintenance contract - circular charts:-i) cc-200 (fc-261)range 0-100, ii) 9/d/179/fc-241, range 0-600, iii) 9/d/147/s-8963, range 0-150, iv) 9/d/112/s-3452, range 0-30, disposable pen (red), temperature gauge dial size 6" (h guru) heavy duty with test certificate (mercury filed) :-i) range 0-150 c streight steam 6", ii) range- 0-150 c capillary type (3 meter) bulb length 10" copper/pvc, iii)range 0-300 c streight steam 6", iv) range 0-500 c streight steam 6", vacuum gauge dial size 6" range- 0-30 inch of hg/760 mm bottom feed connection 3/8" bsp, h guru heavy duty with test certificate., pressure gauge dial size 6" bottom feed connection size 3/8" or 1/2" bsp, h guru heavy duty with test certificate :-i) range 0-15 psi 01 kg/cm , ii) range 0-30 psi 02 kg/cm , iii) range 0-60 psi 04 kg/cm , iv) range 0-150 psi 10 kg/cm , v) range 0-300 psi 21 kg/cm , vi) range 0-1030 psi 42 kg/cm /70 kg/cm , pressure gauge, dial size 10" bottom feed connection size 1/2" bsp heavy duty with test certificate:-i) range 0-60 kg/cm h. guru with test certificate, ii) range 0-2 kg/cm2 h. guru with test certificate, pressure gauge for turbines heavy duty with test certificate:-i) 4" dial size side back connection %" bsp range 0-2 kg/cm , ii) 4" dial size side back connection %" bsp range 0-4 kg/cm , iii) 4" dial size side back connection %" bsp range 0-7 kg/cm , iv) 4" dial size side back connection %" bsp range 0-10 kg/cm , teflon coated compensating cable 2 core j type, compensating cable fg/ss 2-core k type, 4 digit digital temperature indicator j & k typ , thermocouple sensor heavy duty:-i. 12" x 8 mm j/k type, ii. 8" x 8 mm j/ k type, iii. 6" x 6 mm j/k type, oil pocket ss 12", 6 digit digital event counter, proximity switch (magnetic sensor) pnp-nc sensing 8 mm,voltage 5-35 vdc, max load 300 ma, on/off pneumatic controlvalve flange type size- 1" to operate at air pressure 60-80 psi suitable for 20 kg/cm line pressure, on/off solenoid valve for pneumatic valve:-a) air filter " line size female thread, b) air filter with air regulator size 4", digital temperature controller (pid) j & k type, digital tachometer range 0-10000 rpm, 96 x 96 with magnetic sensor., steam flow indicator cum totalizer, drum levelcontroller 4-20 ma input/output model no. 5296at (massibus make), dp transmitter 4-20 ma for boiler drum level, honybell make, positioner for drum levelcontrolvalve, stroke counter for molasses tank, jumbo digital display with sensor, for juice and water tank, current and previous display size 4" x 4"., ma & mv source meter for temp. indicator calibration, pressure transmiter model tsc 01, range 0 to 40 bar, output 04-20 ma, accuracy 0.25% fs, pressure transmiter model ks-e-e-e b02u-m-v, range 0 to 2 bar, output 04-20 ma, supply 9-32 vdc, port g1/4e, syphon pipe s.s. 304 :-(i) u type, (ii) q type, pressure gauge, model en837-1, ss-316, dail size 6", bottom feed connection size 1/2" bsp, heavy duty with test certificate (tempsens make) :-i) range 0-6 kg/cm , ii) range 0-10 kg/cm , iii) range 0-21 kg/cm , iv) range 0-42 kg/cm , pid controller, size 96 96, model no. dc 1040, make honey bell, pressure recorder range, h-guru make, with test certificate (heany duty) with pipe stand mounted ", socket- ", size 10" :-(i) 0-1 kg./cm2, (ii) 0-2 kg./cm2, (iii) 0-10 kg./cm2, orifice with assembly (nipple), inlet pressure 21 kg/cm , outlet pressure 21 kg/cm , inlet temp. 350 c, outlet temp. 350 c, line size 4", drum level transmitter, range 400 to 400 in h2o, (make- honey bell), steam pressure transmitter, range 14.7 to 3000 psi, (make- honey bell), hade mounted thermocouple, length 450 mm, k-type duplex type, with test certificate (heany duty), signal isolator singal input 4-20ma, double output 4-20ma, repair & calibration work with amcsuper-heated wash water temp. controlling system- 01 no., d-super heated exhaust steam temp. controlling system- 01 no., temperature control system of transit heater for c/f machin
Tender For supply of safety items at purnea lpg plant c c - windsocks doublelinen clothwater proof , hand glove lowtemperature rbr 30 degr , handgloves pvc 18inyellow , cotton handgloves , goggles panoramic view chemicalsplash , goggle protective uv protection , gogglesud 50 antifog , goggles uee132wg arc welding , goggles gascutting , ear plugrbr , earmuff universalsoundlevel 135dba , safety shoes , safety toe guard , safetyhelmet hdpe , face shield and safetyhelmet , n95 mask reusable , barricadingtape 2mmx3in , trafficcone conical pu , safetybelt harness polyamide manufactur , blanket water gel , spark arrestorsize 6in , spark arrestorsize 3in , spark arrestorsize 2in , spark arrestorsize 4in , tester breathalcoholmodel 701d victory , hhmd , flp led withenclosure torchvolt 1 point 5v , co2 gas cartridgefor dcp 9 kg fireexti , co2 cartridge for75kg fireextinguisher , inspectionmirror steelsize 610 x 305mm , jet nozzle ss 63mm , universalmultipurposenozzle gunmetal s , vlv sol norgrensingle pilot 5 by 2 , quartz bulbss range 79degc 1 by2 in , nozzle sprinkler size 1 by 2indifferent t , supply of flp esdpush buttons , flp break glassunit , sply of pressureswitch 010 kg flp , sply of pressureswitch 010 kg nonflp , sply of pressureswitch 030 kg , relayvalve 81 point 521166079refueller , siren handoperatedrange 1 point 6km , electrical sirenmin 3 km kirag , sply of lock key , champion gasket , co2 fireextinguisher hosewith handle , dcp fireextinguisher hose , double headhydrant malehosing coupler , fire hydrant linestrainer 6 inch diawi , fire hydrant linestrainer 10 inchdia w , fire extinguisherlock pin , half inch fitting withnipple both side , dcp fireextinguisherpowder , handpump for hsdlifting , enamel paint redsea green lightblue , double endedopen wrench set8x9 to 30x3 , adjustablewrench 36x300 mm , cs ball valve size15 mm , pressure guagedia 100 mm 40 kgss , pressure guagedia 150 mm 30 kgss , pressure guagedia 150 mm 16 kgss , pressure guagedia 50 mm 42 kgss , pressure guagedia 50 mm 16 kgss g , pressure guagedia 100 mm 21 kg ss , pressure guagedia 50 mm 150 kgss , m s pipe size halfinch , m s pipe size 25 mm , ms elbow size halfinch , m s elbow size 25mm , ss float valvesize 50 mm withball , c s gate valve size25 mm , reducer size 25 x15 mm , d e open wrench non sparking 24x26 al br , d e ring wrench non sparking 21x23 al br , d e ring wrench non sparking 24x26 al br , safetyrespiratory face mask single ca , double endedopen wrench set24x27 ss , double ended ringwrench set 24x27ss , double endedopen wrench set14x15 ss , double ended ringwrench set 14x15ss , double endedopen wrench set18x19 ss , double ended ringwrench set 18x19ss , double endedopen wrench set20x22 ss , double ended ringwrench set 20x22ss , allen key set witht shaped holder chrom
Tender For corrigendum : tender for supply of controlvalves - fuel oil flow controlvalve for bpcl bina as per boq line item 1 , pyrolysis fuel oil flow controlvalve as per boq line item 2 , fuel gas flow controlvalve as per boq line item 3 , spray controlvalves as per boq line item 4 , steam to sb pressure controlvalve as per boq line item 5 , cbd levelcontrolvalve as per boq line item 6 , mandatory spares as per boq line item 7 , commissioning spares as per boq line item 8
Tender For corrigendum : repair, maintenance, and installation of plant/ systems/equipments (version 2) - industry unit; tender for the job of obtaining consent to establish for hter scheme at rcf thal unit through nipl route; as per scope of work; a) safety violation by contractor employee at work place: 1) working without wearing safety helmet (per person), 2) working without wearing safety shoes (per person), 3) working without wearing safety goggle &/or hand gloves during handling of hazardous chemicals, acid/alkali etc. (per person), 4) working without wearing safety belt (double lanyard full body harness) for height jobs above 2 meters. (per person), 5) working without wearing face shield during cutting, welding, grinding activity and during maintenance work on process lines and equipment. (per person), 6) not using ppe, tools/tackles as mentioned in safety work permit (per person), 7) working without valid test certificate for lifting tools/tackles (per incidence observation), 8) working without appropriate electric plug-pin, elcb/rccb/rcbo (per incidence observation), 9) working without a valid safety work permit (per incidence/ observation), 10) permit not available at site (per incidence/observation), 11) gas cylinder without flash back arrestor (per incidence observation), 12) gas cutting set with damaged hose pressure gauge without valve key (per incidence/observation), 13) gas cylinder without trolley (filled and empty) (per incidence/ observation), 14) unauthorized personal entering into cordon off area (per incidence/observation), 15) faulty wire/cable laying on ground or using snapped cables (per incidence/observation)., 16) improper hand tool or power tools (per incidence observation), 17) smoking at work place area. (per person), 18) found in intoxicated state (per person), 19) violation of road rules (per incidence observation), 20) b) safety violations by transport contractors, 21) faulty hazchem displayed on tanker (per incidence observation), 22) one pvc/tychem suit set if available (per incidence/ observation), 23) both pvc/tychem suit set are not available (per incidence observation), 24) fire extinguisher without hydro test. (per incidence/ observation), 25) trem card not available (per incidence/observation), 26) hazardous chemicals transportation training of driver by authorized agencies. (training card not available with driver) (per person), 27) lying/resting below the vehicle(per incidence/observation), 28) any other deviation found as per checklist for tankers (per incidence/ observation.
Tender For supply of instrument spare and annual maintenance contract - circular charts:- i) cc-200 (fc-261)range 0-100, ii) 9/d/179/fc-241, range 0-600, iii) 9/d/147/s-8963, range 0-150, iv) 9/d/112/s-3452, range 0-30, disposable pen (red), temperature gauge dial size 6" (h guru) heavy duty with test certificate (mercury filed) :- i) range 0-150 c streight steam 6", ii) range- 0-150 c capillary type (3 meter) bulb length 10" copper/pvc, iii)range 0-300 c streight steam 6", iv) range 0-500 c streight steam 6", vacuum gauge dial size 6" range- 0-30 inch of hg/760 mm bottom feed connection 3/8" bsp, h guru heavy duty with test certificate., pressure gauge dial size 6" bottom feed connection size 3/8" or 1/2" bsp, h guru heavy duty with test certificate :- i) range 0-15 psi 01 kg/cm , ii) range 0-30 psi 02 kg/cm , iii) range 0-60 psi 04 kg/cm , iv) range 0-150 psi 10 kg/cm , v) range 0-300 psi 21 kg/cm , vi) range 0-1030 psi 42 kg/cm /70 kg/cm , pressure gauge, dial size 10" bottom feed connection size 1/2" bsp heavy duty with test certificate:- i) range 0-60 kg/cm h. guru with test certificate, ii) range 0-2 kg/cm2 h. guru with test certificate, pressure gauge for turbines heavy duty with test certificate:- i) 4" dial size side back connection %" bsp range 0-2 kg/cm , ii) 4" dial size side back connection %" bsp range 0-4 kg/cm , iii) 4" dial size side back connection %" bsp range 0-7 kg/cm , iv) 4" dial size side back connection %" bsp range 0-10 kg/cm , teflon coated compensating cable 2 core j type, compensating cable fg/ss 2-core k type, 4 digit digital temperature indicator j & k typ , thermocouple sensor heavy duty:- i. 12" x 8 mm j/k type, ii. 8" x 8 mm j/ k type, iii. 6" x 6 mm j/k type, oil pocket ss 12", 6 digit digital event counter, proximity switch (magnetic sensor) pnp-nc sensing 8 mm,voltage 5-35 vdc, max load 300 ma, on/off pneumatic controlvalve flange type size- 1" to operate at air pressure 60-80 psi suitable for 20 kg/cm line pressure, on/off solenoid valve for pneumatic valve:- a) air filter " line size female thread, b) air filter with air regulator size 4", digital temperature controller (pid) j & k type, digital tachometer range 0-10000 rpm, 96 x 96 with magnetic sensor., steam flow indicator cum totalizer, drum levelcontroller 4-20 ma input/output model no. 5296at (massibus make), dp transmitter 4-20 ma for boiler drum level, honybell make, positioner for drum levelcontrolvalve, stroke counter for molasses tank, jumbo digital display with sensor, for juice and water tank, current and previous display size 4" x 4"., ma & mv source meter for temp. indicator calibration, pressure transmiter model tsc 01, range 0 to 40 bar, output 04-20 ma, accuracy 0.25% fs, pressure transmiter model ks-e-e-e b02u-m-v, range 0 to 2 bar, output 04-20 ma, supply 9-32 vdc, port g1/4e, syphon pipe s.s. 304 :- (i) u type, (ii) q type, pressure gauge, model en837-1, ss-316, dail size 6", bottom feed connection size 1/2" bsp, heavy duty with test certificate (tempsens make) :- i) range 0-6 kg/cm , ii) range 0-10 kg/cm , iii) range 0-21 kg/cm , iv) range 0-42 kg/cm , pid controller, size 96 96, model no. dc 1040, make honey bell, pressure recorder range, h-guru make, with test certificate (heany duty) with pipe stand mounted ", socket- ", size 10" :- (i) 0-1 kg./cm2, (ii) 0-2 kg./cm2, (iii) 0-10 kg./cm2, orifice with assembly (nipple), inlet pressure 21 kg/cm , outlet pressure 21 kg/cm , inlet temp. 350 c, outlet temp. 350 c, line size 4", drum level transmitter, range 400 to 400 in h2o, (make- honey bell), steam pressure transmitter, range 14.7 to 3000 psi, (make- honey bell), hade mounted thermocouple, length 450 mm, k-type duplex type, with test certificate (heany duty), signal isolator singal input 4-20ma, double output 4-20ma, repair & calibration work with amc super-heated wash water temp. controlling system- 01 no., d-super heated exhaust steam temp. controlling system- 01 no., temperature control system of transit