Get complete information related to latest Lifting Hook Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Lifting Hook Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Lifting Hook Tenders.
Tender For supply of spares for existing 50t eot crane : loco lifting tackler assembly, capacity 65 t for lifting of wap 7 & wag 9 locomotives as per scr drawing no. b/els/bza/7, alt-a, dt: 1.5.2026. (note: in item reference no. 4 of said drawing : diameter of pin for hook shall be 135 mm, length 320mm and liftinghook pin centre distance is 260 mm instead of 324 mm). note: 1) manufacturer name and year of manufacture to be engraved on the tackler. 2) lifting tackle shall be tested to lift 97.5 ttest load before commissioning and test certificate should be provided from nabl certified lab along with supply. [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For tender for supply of equipment / material , design, erection, testing & commissioning for sop to civil hospital jawalamukhi by providing 11/0.4 kv, 400 kva dtr a/w 11 kv ht line in electrical section amb under esd hpsebl no-i jawalamukhi, ed jawalamukhi. - supply part of 11 kv ht line with aaac 7/3.81 (0.065 km), steel tubular poles 11 mtr. long with base plate, muff for steel tubular pole with concrete filling, aaac conductor 7/3.81, 80 sq. mm ( includes 3 conductor length and additional 1% sag (sag, jumpering and wastage)), single continuous earth wire (g.i wire 8 swg), cross-arm {channel iron (100x50x6 mm), length 1270 mm}, 11 kv pin insulators ( porcelain, 12 kv, 10 kn): 3 no. per pole structure, ai (50x50x6 mm), length 750 mm x2 no., x-bracing set -ms angle iron 50x50x6, length {2125 mmx2 no }, pole top bracket (100x50x6 mm), length 100 mm, ht stay set complete, stay wire, earthing set ht complete in all respect, eye hook for earth wire, barbed wire (rec sp f 3-1981), half clamp, full clamp, danger plate (250x200x1.6 mm), nuts & bolts off sizes, 11 kv g.o. switch, d.o fuse unit, aluminium paint, red oxide point, supply part of 11/0.4 kv 400 kva distribution sub-station, steel tubular poles 9 mtr. long, muffs with concerete filling, x-arm: [channel iron (100x50x6 mm), length : 2800 mm x 2 nos], ms angle iron (50x50x6 mm), length: 2800 mm x(1 nos for las), x-arm: [channel iron (75x40x6 mm), length : 2800 mm x 4 nos] for supporting do fuse unit & go switch, x-arm [channel iron (100x50x6 mm), length : 2800 mm x 2 nos for transformer bed, x-arm [channel iron (100x50x6 mm), length : 460 mm x 2 nos for supporting main channel of transformer, ms angle iron (50x50x6 mm), length : 2800 mm x 2 nos, ms angle iron 35x35x5 mm), length : 460 mm x 2 nos, ms angle iron 50x50x6 mm), length : 950 mm x 2 nos for bed knee bracing, ms angle iron (50x50x6 mm), length : 2800 mm x 2 nos for lt distribution box and go switch assembly, ms angle iron (50x50x6 mm), length : 450 mm x 1 nos for lt distribution box and go switch assembly, go switch handle supporting : [ channel iron (75x40x6 mm), length:460 mm, go ab switch unit (11kv, 400a, 25 ka ) triple pole o/d type, d.o fuse unit, surge arrester, 9 kv station class (porcelain type), discs insulator sets (comprising 1 no. disc: ^^(porcelain, bs, 12 kv, 90 kn) including dead end clamps etc.), stay set complete, stay wire, pipe earthing set, gi wire (6 swg) earth wire, half clamp (m.s. flat 50x6 mm), full clamp ( m.s flat 50x6 mm), nuts and bolts of various sizes (galvanised / coated), aluminium thimble 300 sq mm, copper thimble 95 sq mm, danger plate, barbed wire, lt cable 3.5 core 400 sq. mm, lt cable 3.5 core 70 sq. mm, aluminium paint., red oxide, transformer bed (civil work), chain link fencing, angle iron, gate etc. for transformer fencing, ct pt combined unit, energy meter (3-ph, 4-wire) dlms compliant 1000/5 a ct type for 400 kva dtr, pvc multistrand 2.5 sq mm copper wire, ms angle iron (50x50x6 mm) length 2800 mm x 4 nos., ms angle iron (50x50x6 mm) length 450 mm x 2 nos., erection part of 11 kv ht line, erection charges & transportation charges complete in all respect of 11 kv ht line, erection part of 400 kva dtr, erection charges & transportation charges complete in all respect of 11/0.4 kv, 400 kva dtr
Tender For corrigendum : 15/edc(blp)/2026-27 - loading, unloading and safe cartage of the following materials from electricity store centre, balrampur to the work site/dump site (distance up to 50 km), st poles (11 mtr long), pcc poles (8.5 mtr long), acsr weasel conductor, lt abc 3x120+1x95+1x16sq.mm., 100 kva t/f, other line materials, erection of single st poles (11 mtr long) for 11 kv/l.t. line alongwith fitting of all accessories on pole including dragging of pole from dump site to pit site, erection of single pcc poles (8.5 mtr long) for 11 kv/l.t. line alongwith fitting of all accessories on pole including dragging of pole from dump site to pit site, erection of sectional double pole sectional pcc pole (8.5 mtr long pcc pole) alongwith fitting of all accessories on pole including dragging of pole from dump site to pit site., earthing of pole as per uppcl/resspo norms.., erection and grouting of stay sets alongwith complete fittings. cement, sand & brick ballast provided by the contractor at his own cost., grouting of poles with 1:4:8 cc ratio of cement, sand & brick ballast, backfilling of pits with mud completely.all required materials provided by the contractor at his own cost., laying, stringing, sagging & binding of conductors of 11 kv in 3 phase, 3 wire line with jumpering (where as required), laying, stringing & sagging of 3x120+1x95+1x16sq.mm. abc cable up to proper sag for the following size cable, construction of 11/0.4 kv s/s for 100 kva t/f with mounting and fitting of t/f on plinth/double pole with proper fitting of all acessories and connecting with all circuit including earthing of t/f fitting with all accessories., earthing of distribution t/fs for body & neutral upto water level with gi pipe of 1.5" dia. including gi strip size 35x6 mm. (all material will be supplied by contractor)., decentralized materials:-providing and fixing of following materials as per sanctioned estimate/package as per resspo u.p.p.c.l. drawing/ norms.(where is required)., suspension clamp with i hook, i hook, suspension clamp with i hook, i hook, lt fuse set., lt pvc cable al 1x120sq.mm., lt pvc cable al 1x400sq.mm., lug sutable for 250 kva, suspension clamp with i hook, i hook, lt fuse set., lt pvc cable al 1x120sq.mm., lt pvc cable al 1x400sq.mm., lug sutable for 250 kva
Tender For corrigendum : supply of jacket divers dress neoprene 3mm thickness medium , jacket divers dress neoprene 3mm thickness large , jacket divers dress neoprene 3mm thickness small , long john diver dress neoprene 3mm thickness medium , long john diver dress neoprene 3mm thickness large , long john diver dress neoprene 3mm thickness small , boots divers dress neoprene 3mm thickness small , boots divers dress neoprene 3mm thickness medium , boots divers dress neoprene 3mm thickness large , hood for divers neoprene 3mm thickness each set having one each in three sixes s,m and l , gloves for divers neoprene 3mm thickness each set having one each in three sixes s,m and l , mask swim silicon , tube snorkel , swim fins rubber set of pair , swim fins improved graphite with back strap set of pair , swimmer knife with sheath light and rustproof , multipurpose divers knife tool with sheath , underwater digital video cameras with casing , divers life belt , weight belt diver with four or six pouches , buddy line with inglefield clip , lead weight set of 1 and 2 kg , diving ladder adjustable , diving marker float spherical buoyancy 10kgs , iron sinker with hook 25kg , divers lifeline 8mm sisal or manila or manmade fiber length 220m continuous in each set , underwater flood light 1000 watts complete hand held , uw light high power with cable 50 mtrs and surface supply accessories , lamp search divers complete head mounted with rechargeable battery charger and bulb 50 watts , divers uw communication system with battery compatible with diving set , divers uw wireless communication system , portable hp diesel driven diving air compressor 5 to 6 cfm with 5 years spares working pressure up to 300 bars , lp washing kit with 60 feet soft hose and adjustable pressure nozzles , underwater digital still camera with casing , onboard spares , installation and commissioning spares
Tender For corrigendum : preferential purchase scheme-vib-rcc slabs - supplying of factory made precast rcc slabs at site in concrete grade of m-25 with 20mm nominal size granite or basaltic aggregate, consolidated by means of mechanical platform, vibrator etc. with liftinghooks of m.s. 10 mm bars and pvc cups including cost of reinforcement etc., complete, a. size 900x400x150mm with steel reinforcement not less than 7 kg per unit 30t capacity, b. size 900x400x100mm with steel reinforcement not less than 5.0 kgs per unit 12t capacity, c. size 750x400x100mm withsteel reinforcement not less than 4.2 kg per unit, d. size 700x500x75mm with steel reinforcement not less than 3.0 kg per unit, e. size 600x500x75mm with steel reinforcement not less than 3.0 kg per unit, f. precast rcc slabs of size 1200x400x100mm with steel reinforcement not less than 7 kg per unit-12 t capacity., g. precast rcc slabs of size 1200x400x150mm with steel reinforcement not less than 10 kg per unit-30 t capacity., h. precast rcc slabs of size 1500x400x150mm with steel reinforcement not less than 12 kg per unit-30 t capacity. - supplying of factory made precast rcc slabs at site in concrete grade of m-25 with 20mm nominal size granite or basaltic aggregate, consolidated by means of mechanical platform, vibrator etc. with liftinghooks of m.s. 10 mm bars and pvc cups including cost of reinforcement etc., complete, a. size 900x400x150mm with steel reinforcement not less than 7 kg per unit 30t capacity, b. size 900x400x100mm with steel reinforcement not less than 5.0 kgs per unit 12t capacity, c. size 750x400x100mm withsteel reinforcement not less than 4.2 kg per unit, d. size 700x500x75mm with steel reinforcement not less than 3.0 kg per unit, e. size 600x500x75mm with steel reinforcement not less than 3.0 kg per unit, f. precast rcc slabs of size 1200x400x100mm with steel reinforcement not less than 7 kg per unit-12 t capacity., g. precast rcc slabs of size 1200x400x150mm with steel reinforcement not less than 10 kg per unit-30 t capacity., h. precast rcc slabs of size 1500x400x150mm with steel reinforcement not less than 12 kg per unit-30 t capacity.