Get complete information related to latest Lt Breaker Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Lt Breaker Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Lt Breaker Tenders.
Tender For supply of cooling tower spares & service cooling tower no. 1, spares parts of cooling tower ,ac b eliminator 71 ,ac b eliminator 58 ,r.c.c. spacer ,s.s. wire grid 44 y76 (14 swg )(4 x 12 ) 1hw01194 ,pvc v bar 8 8 , code mpf01047 ,cable tie 6 ,target nozzle ,s.s. wire 14 swg ,work details;- *dismantling & re- fitting of s.s. wire grid & pvc v bar properly in all respect. *dismantling & re-fitting after cleaning of acb drift eliminator along with ,rcc spacer complete in all respect. *binding of s.s. wire grid with rcc beam should be properly done. *fitting of target nozzles at position should be done. *cell ,repairing all work should be done completely to insure the trouble free working of cooling tower during the season. *minor repairing jobs for other cells also to be done. ,spares for paharpur cooling tower model 1400-02-(16 at) ,spare coupling with distance shaft pipe (for gear box to motor connection)flange, flow control (f.c) valve size 12 dia.
Tender For supply of lauritz knudsen (formerly l & t) make switchgear spares for chp elect- fuel section at gsecl ukai tps. (chp maintenance (electrical)-et-6304) - l&t make 3 pole power contactor, type- ml-2, ac-3, 32 a, 415 v ac, l&t make,3pole power contactor in open execution type ml-4 for ac.ckt. with 2 not 2nc aux- contact,coil voltage 110vac, ac-3 rating 70a cat.no.ss 90910, l&t make 415v switch gear (acb), l&t make,3pole power contactor ml-6,coil voltage 110vac, ac-3 rating 110a cat.no. ss90921, l&t contector-ss91010 3pole 300a 3ph,ml12 2no+2nc, l&t make 3 phase power contactor type mnx 25 ac-3 rating 25a,cat.no.cs94110, l&t make 3 phase power contactor type mnx32 ac-3 rating 32a,coil voltage 110v ac,cat.no.cs94111aooo, power contactor mnx 40 coil:110vac cat no.:-cs94190 make:-l&t, l&t make 3 phase power contactor type mnx110 ac-3 rating 110a,coil voltage 240v ac,cat.no.cs94137, l&t make power cantactor type- mnx 300 with 2 no + 2 nc aux. contact, coil voltage 110 volt ac, ac-3 rating 300 amp., cat. no. cs 90280., l&t make,3pole power contactor in open execution type mn-400 for ac.ckt. with 2 not 2nc aux- contact,coil voltage 110vac, ac-3 rating 400 * cat.no.ss 94043, l&t make 415v switch gear (acb), contactor kit ml-2 ss 95307, l&t make contact kits with out coil for contactor type:- ml 4, cat.no - ss 91257, spares kit without coil for contactor ml6, cat. no. ss 95313, make - l & t, l&t make spare kit without coil for ml-10 cat no ss 95315, l&t make 415v switch gear (acb), l&t make spare kit without coil for ml-12,cat no.ss 91127,l&t make 415v switch gear (acb), spare contact kit for l&t make mnx 110 power contactor cat no cs94154, spare contact kit for l&t make mnx 400 power contactor cat no cs94161, coil for l&t make power contactor. ml-8/10/12 ss91011, 220vac,/110vac, l&t make spare coil for mnx 400, coil voltage 110 vac, cat no cs94195, l&t make fornt mounting add-on block 2no + 2nc cat. no.cs94114 for mnx 9a to 40a contactor, l&t make, mnx type front mounting add on aux. contact block 1 no + 1 nc, cat no cs94118, l&t make, mnx type front mounting add on aux. contact block 3 no + 1 nc, cat no cs94113, l&t make control , contractor type mm01 with 4 ho +4hc contact , coil voiltage 110 vac cat no. ss 92014, l&t make 415v switch gear (acb), l&t make control contactor, type mm01 ac with 5 no +3nc contact , coil voiltage 110 vac, cat no. ss 92014, l&t make 415v switch gear (acb), l&t make dc control mx mini mx 09 1nc cat no cs94024, l&t make bi metal o/l relay for ml -2 range 9.0-14a , cat no ss 9185900ao, l&t make 415v switch gear (acb), l&t bimetal thermal overload relay with single phasing protection.mn-2 9.0-15.0a ss94142, l&t make ml type,thermal overload relay, range 20-32amp,direct mounting on ml 2/3 contactors,cat no-ss91859ooeo, bimetallic relay with single phasing protection, range: 66-110a, make: l&t, cat. no.-cs9422700k0, l&t make bimetal thermal over load relay with single phasing protection, mn 12 type, cat.no. - ss94138oomo, relay range 3 - 5 amp operation, ct operated in combution with 90 - 150 amp (ct operated) seprate mounting., l&t make b/m o/l relay,mn-12 l type,range-180-300a,cat no-ss 94127 ooqo, l&t make bimetal (th) over load relays ( with single phasing protection) thermal o / l relaytypemn 2cat.no.ss 9412700 porelay range3 - 5 ampoperationct operatedin combution with 90 - 150 amp ct mounted on ct, switch disconnector fuse unit tpn 32a 415v make:-l&t type:-fn, l&t make switch disconnector (415 volt, 50 hz) fuse units type: fn 63 tpn, cat.no.: sk 95421, capacity:- 63 amp, ac, 23 amp, no of poles: 3 + n link, l&t make switch disconnector-fuse, type-fn 125, 125amp, tpn+fuse links, cat no- sk 95001., l and t make switch disconnector isolator, type fn 250 tpn, cat. no. sk95683., landt make switch disconnector-fuse, type-fn400, 400amp, tpn, cat no
Tender For corrigendum : : supply, installation, testing & commissioning of electrical equipment for dg block 119a of inrp - ht panels (119a)supply, installation, testing & commissioning of indoor type floor mounted, single front, metal clad, 1250 a, 6.6 kv, 3 phase, 3 wire, vcb switchgear panel suitable for a short circuit current of 31.5 ka for 3 seconds, internally arc tested for 31.5 ka for 1 second, comprising of following incoming & outgoing feeders : incoming feeder: 1 no. 1250 a, 3p vcb outgoing feeders: i) 7 nos. 630 a, 3p vcbii) 1 no. 1250 a, 3p vcb as tie feederwith surge arrestors, relays, pts, cts & other necessary accessories including associated structural steel required for complete installation of the panel & equipment earthing of the panel from both the earthing terminals of the panel to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & drawings. reference drg. nos: ip1/119a/05027339/dwg/001/r0 & ip1/119a/05027339/dwg/002/r0(note: terminal box of each incomer of 6.6kv switchboard shall be suitable for terminating 4x3cx400 sq.mm., 6.35/11kv (e), a2xwy cables.), supply of spares for ht panels as per attached spares list mentiond in section c, part ii of tender, 2.5 mva, 6.6/0.433 kv dry type transformers (119a)supply, installation, testing & commissioning of 6.6/0.433 kv, 2.5 mva, dyn11 dry type cast resin transformer having percentage impedance of 8.5% complete with ht cable end box, lt bus duct flange, off load tap changer on ht side with range of +/-5% in steps of 2.5%, wti scanner, ct for restricted earth fault protection and other necessary accessories including associated structural steel required for complete installation of the transformer & equipment & neutral earthing of the transformer from both the earthing terminals of the transformer to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & drawings.reference drg. no. : ip1/119a/05034347/dwg/001/r0, supply of spares for dry type transformers as per attached spares list mentiond in section c, part ii of tender, 2000 kva diesel generator sets (119a)supply, installation, testing & commissioning of 3 phase 2000 kva prime power 433v, 50hz, 0.8 p.f. diesel-generator sets with 110% overload capacity for 1 hr with four (4) stroke inline or vee type cylinder arrangement having engine speed 1500 rpm, 24v electric battery starting system with a provision of interchangeability of battery bank between two dg sets, complete with all auxiliary equipment including amf control panel, auxiliary mcc panels, heat exchanger cooling system, raw water pump, remote radiator with fans on terrace, ms exhaust piping, exhaust structure (maximum 30 m stack), 4 nos. of 3.6 cubic metre fuel day tank outside dg building (for all 4 dg sets) & 1 no. of 990 ltr intermittent tank inside each dg room, ms "c" class fuel piping between engine & fuel tank, dg room accoustic treatment & complete ventilation of dg room, brushless excitation for alternator, one no. 3200 amp 415 v 4p acb, ms structural steel supports/ channels/ angles & other necessary accessories including associated structural steel required for complete installation of the dg & equipment & neutral earthing of the dg from both the earthing terminals of the dg to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & necessary statutory clearances from cpcb etc. as required and as per tender technical specifications & drawings. design and construction of foundation for exhaust pipe rack/ structure of dg set is included in the scope of the contractor.reference drg. nos. : i) ip1/119a/05034347/dwg/001/r0ii) ip1/119a/05044831/dwg/003/r0iii) ip1/119a/05044831/dwg/004/r0iv) ip1/119a/05044831/dwg/005/r0v) ip1/119a/05044831/dwg/006/r0, supply of sp
Tender For providing of custom bid for services - contract for overhaul and testing of lt numerical relays and its associated ltbreakers during the overhaul of unit- 1 & 2