Get complete information related to latest Lt Breaker Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Lt Breaker Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Lt Breaker Tenders.
Tender For providing of custom bid for services - contract for overhaul and testing of lt numerical relays and its associated ltbreakers during the overhaul of unit- 1 & 2
Tender For supply of semi conductor fast acting fuse, rating 1000/1250 volts, 1450 amps for bg ac emu main rectifier unit confirming to specification icf/elec/021 rev. "a" clause 6.5 similar to bussman type matched pair of 170l 9598/ferraz fz 12.5 urc 273 ttf 1450 (ref.no.p 301428 a) (make: siemens/l&t/c&s/bussmann/kel/r.b.commercial corporation only preferred ) [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For corrigendum : supply of ht and ltbreaker spares - sc210290424 mccb, model-dm16, rating -1.6a,40 deg c ui 690v, 50 or 60hz, icu-65ka, ics-75 percent icu, instantan- 19a, is 13947-2 iec 60947-2, utilisation category-a, with limit switch landt or equi , sc210290427 mccb, dn2- 160h3,63a landt or equivalent , sc210170054 mccb,make- landt model dm100,rating-25a 40 deg c,ui- 690v,50 or 60hz,icu -65ka,ics-75 percent,instantan-300a,is 13947-2 or iec 60947-2,utilisation category-a,with limit switch landt or equi , sc210290425 mccb,model-dm16,rating - 7.5a 40 deg c, ui 690v, 50 or 60hz, icu-65ka,ics-75 percent, instan- 90a,is 13947-2 or iec 60947-2,utilisation category -a,with limit switch landt or equi , sc210290426 mccb,model- dm16,rating -5 a,40 deg c ui 690v, 50 or 60hz, icu- 65ka,ics-75 percent icu, instan-60a,is 13947-2 or iec 60947-2,utilisation category, with limit switch landt or equi , sc210170088 mccb,model-dm160,rating -160 a,40xc ui 690v,50 or 60hz, icu-65ka, ics-75percent icu,instan-1920 a,is 13947-2 or iec 60947-2,utilisation category -a,with limit switch landt or equi , sc210290429 mccb ,model- dm100,rating -80 a,40xc ui 690v,50 or 60hz,icu-65ka,ics- 75percentage icu,instan-960 a,is 13947-2 or iec 60947- 2,utilisation category -a,with limit switch landt or equivalent , sc210290428 mccb , model-dn3-400m, rating -400a, ui 415 or 440v, 50 or 60 hz, u 8kv, icu - 50ka, ics 100percent icu, cat - a,is or iec 60947-4,with limit switch landtor equi , sc050130075 power contactor, 3 pole, type no mnx 80, rating 80a, coil voltage 110v ac for chp,with add on block make-landt , sc050130064 u power spring charging motor, 240v ac for chp, make - landt , sc050130084 contactor,3 pole, type no mnx 140,rating 140a, coil voltage 110v ac for chp,with add on block make - landt , sc050130056 contactor, 3 pole, type no mnx 50, coil voltage 110v ac for chp,with add on block make - landt , sc050150366 power contactor mnx265, with add on block,265 a 415 v 3 pole 2no plus 2nc make - landt , sc050150365 power contactor mnx110, 230 ac coil supply,110a,415v, with add on block, 2no plus 2nc make - landt , sc050150367 power contactor, 3 pole, type no mnx 50, with add on block, coil voltage 230v ac for chp. make - landt , sc050150358 contactor,mno 40e, coil voltage 110,4no 4nc make - landt , sc050150359 contactor, mno 31e,coil voltage 110 v ac make - landt , sc050150360 contactor,mno 22e, coil voltage 24v dc make - landt , sc050150364 contactor,mxo 22e,coil voltage 110vdc, ac-15, ue 415v - ie4a,ui 690v, lth-10a make - landt , sc050150363 contactor,mxo 22e, 220vdc, with add on block make - landt , sc050150362 contactor,mx0 40e, 220vdc, with add on block make - landt , sc050150361 contactor,mx0 31e, 220vdc,with add on block make - landt , sc210290423 mpcb, 415v, rotary type, thermal magnetic, 1-1.6 a, mog-h1-0401, make - landt or equivalent , sc210290419 rcbo,415v, 32a,4 pole,100ma make - landt or equivalent , sc210290420 rcbo,415v, 32a,2 pole, 32ma make - landt or equivalent , sc210290422 rcbo,415v, 32a,4 pole,32ma make - landt or equivalent , sc210290421 rcbo, 415v, 32a,2 pole, 100ma make - landt or equivalent
Tender For corrigendum : supply of 4500 sets of stay set complete - supply of silicagel blue, 0.6kva ups, stay set complete( quote price for single unit only), silicagel blue 10 to 12mm, pole pit for 9.0m and 9.14 m psc/rcc / all metal poles (each pit) 1.25 x 0.6 x 1.83 mtr, ordinary soil, semi rocky soil, heavy rocky soil where blasting/ cheseling required [specific approval should be obtained from concerned ee], stay pit, in ordinary soil [0.95 x 0.6 x 1.2m], semi rocky soil, stay pit in heavy rocky soil where blasting/ cheseling reqiured [specific approval should be obtained from concerned ee], erection of poles & stays (including refilling of excavated earth), erection of 7.5m / 8.0m poles [rcc / psc], erection of 9.00m / 9.14m rcc / psc/rail pole, tubular pole and all metal poles, stay set, erection stay set complete, stay erection without rod and pit, replacement of stay rod only. (including stay pit excavation & refilling & erection), replacement of guy shackle only in existing stay, erection of line materials, fixing of lt 1 ph "x" arm, fixing of lt/ht ti fitting, fixing of lt 3 ph "x" arm, fixing of 3[1/2] v ` x arm, fixing of 4[1/2] v ` x arm, fixing of 5 v x arm, fixing of tapping channel / guarding "x" arm, providing of line spacers in lt lines 1 phase, providing of line spacers in lt lines 3 phase, erection of ab switch with pt insulator & jumpering complete, erection of centre rotating switch ab switch complete, fixing of ht pin insulator / strain disc, 11 kv pin insulator with pin, 11 kv strain disc / polymer disc with hardware, 22 kv pin insulator with pin, 22 kv strain disc / polymer disc with hardware, 33 kv pin insulator with pin, 33 kv pin strain disc/polymer disc with hardware, fixing of lt pin insulator with pin, lt shakle with hardware, fixing of aluminium knob, paving stringing and sagging of conductor including binding of pin and proper tight [including transport of condutor from road side to work spot] per run, upto 7/2.59 mm acsr, 7/2.50 aaac including pvc cable upto 25 sqmm, acsr 7/3.35mm & 7/ 3.15 aaac including pvc cable above 25 sqmm, acsr 7/4.09 mm, above 7/4.09 mm acsr & dog conductor, earthing wiring and connection including transporting of earth pipe and excavation of pit], transformer structure earthing 10ft depth - 3 nos of pipe through tubes, dp earthing including all works [double side earthing], erection of 4th earth pipe including earthing, earthing of poles, earth pit masonary work 3 nos earth pits or using 3 nos concrete tub., replacement of detoriated earth pipe per location, concreting with mixture 1:3:6 [including all materials]., mass concreting for centre support for 2 feet including all materials, mass concreting for pole0.6x0.6x1.25m.with coping, sleeve concreting for pole 0.6 m x 0.6m x 0.3 m with coping, sleeve concreting for stay set 0.3 m & 0.75 long, erection of distribution transformer structure complete, excavation of structure pole pits 0.9 x 0.9 x 1.83 mtr, transporting of pole to pit location 2 nos., erection of poles 2 nos, excavation of stay pit 4 nos, erection of stay set (4 sets), mass concreting (cement:sand:jelly supplied by the contractor) 2 nos., erection of 22 kv ab switch, ttransformer structure earthing 10ft depth - 3 nos of pipe through earth tubes, erection of top channel, bed channel [2 nos channel] erection, cross with stud for bed channel erection, erection of belting angle / hg fuse angle, erection of hg fuse set, erection of ht las with jumpering and earthing, erection of lt las with jumbering and earthing, erection of jumpering [ht side], transformer wiring in lt side including jumpering bus bar etc., erection lt open type fuse unit arrangement single, erection lt open type fuse unit arrangement double, painting of stru. complete excluding dt [two coat of red oxide] all metal parts(excluding cost of paint)., painting of stru. complete excluding dt [one coat alu paint, excluding cost of paint), colour washing of 2 numbers structure p