Get complete information related to latest Lt Module Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Lt Module Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Lt Module Tenders.
Tender For supply of spares for lt switchgear panels under chp section ctps dvc - power contractor(ac) with 1no aux. contact coil voltage 240v ac type- lc1-d633-63a, ltmodule incoming, male+female lyra contacts of upto 100a induvidual pole, make-c&s, ltmodule outgoing, male+female lyra contacts of upto 100a induvidual pole, make-c&s, ltmodule incoming, male+female lyra contacts of 250a induvidual pole, make-c&s, ltmodule outgoing, male+female lyra contacts of 250a induvidual pole, make-c&s, power contactor 3pole ac, 80a, coil voltage=240v ac , ui=660v, refernce lc1-d803u5a60, power contactor with coil voltage 240/220 v ac,rating-32a ,type-tc1d3210-m5,make-c&s(psl-5), contactor ac power 3p, ac, 150 a, coil voltage=240v ac, vi=660v reference no. lc1-f-dp150, 415v ac, 185a power contactor with 2 no + 2 nc aux. contact with 240v ac coil, ty: pe lc1-, f185a+lx1-fg+la1-d22, make (c & s), tp) switch fuse unit with 1no+1nc aux, type cssdf32d3 rating-32a, switch fuse unit (tp) with 1no+1nc aux.cont. type:-cssdf125d3,125a, switch auxiliary 14 way(7 no + 7 no) for acb rating upto 2000-3200a, reference cs-axh-7a7b-220, relay thermal overload direct mounting relay setting range 0.63-1a ref tr2-d09305, thermal over load relay direct mounting relay setting range 2.5-4a ref- lr1-do9338, bi-metallic o/l relay, rating-48-65a,make-c&s,type-tr2d65359 (psl-6), relay thermal overload direct mounting relay setting range 17-25a ref tr2-d25322, control relay 10a, contact arrangement 2no+2nc, refernce tca3-dn22md, (coil voltage 220dc), control relay 10a, contact arrangement 4no, refernce tca3-dn40md, (coil voltage 220dc, control relay 10a,4 no ac referance tca2-dn40v5, coil voltage 240 v ac, 240v, 10a, auxiliary contactor with 2 no + 2 nc contact type: ca2d1229, make (c & s), closing coil limit switch ,product code: cclimsw, power contactor 3pole ac, 16a, coil voltage=240v ac , ui=660v, refernce lc1-d173u5a60, control relay 10a, contact arrangement 3no+1nc, coil voltage 240ac; reference tca2-dn31, switch disconnector fuse unit,250a,tpn, type:cssdf250d3n+cssdfzx33, 63a, triple pole switch fuse unit type cssdf63d3n make (c & s), overload relay (make:c&s) range:38-50a type:lr1-d63357., contactor power 3p ac 115a, coil voltage 240v ac, vi=660v, ref.- lc1-f115v or equivalent, contactor ac power 3p, ac, 18 a, coil voltage=240v ac, vi=660v reference no. tcid1810, thermal over load relay type lr1 direct mounting relay setting range 5.5-8a,refrencr lr1-, d09312, ui-660v, relay thermal overload direct mounting relay setting range 5.5-8a ref tr2-d09312, relay thermal overload type lr1 direct mounting relay, setting range 57-66a ref: lr1-d63361, vi=660, thermal overload relay direct mounting ralay setting range 1-1.6a, relay thermal overload setting range 0.63-1a ref: lr1-d09305 vi=660, add on block 2 no ref: ta1-dn20, add on block 1 no+ 1 no ref: ta1-dn11, add on block 2 no+ 2 no ref: ta1-dn22, relay thermal overload direct mounting relay setting range 12-15a ref tr2-d15321, control relay 10a, ac referance tca2-dn22v5, coil voltage 240 v ac, acb(tp), electrically oprated drawout type, without realeases type -ah-8d-cs- 800a, in=800a,, ue=415v,ui=1000v, f=50/60 hz,icu=ics= 50 ka, ics(1s)=50k
Tender For notice inviting limited tendernotice no: 01/elect./2026/ 706 date:- 10.06.2026tools & equipments of –electrician trade- heavy duty screwdriver insulated , electrician screwdriver thin stem insulated handle, , knife double bladed electrician, , chisel firmer with wooden handle, , grease gun, , (a) crimping tool, , wire cutter and stripper, , hacksaw frame, , tweezers, , drill hand brace, , plane cutters, , smoothing cutters, , file flat rough, , file flat bastard, , file rasp, half round, , the soldering gun, , contactor & auxiliary contacts (rm), , contactor & auxiliary contacts. (rm), , pin type, shackle type, egg type & suspension type insulators including hardware fitting, , portable electric drill machine, , load bank (lamp/heater type), , brake test arrangement with two spring balance rating, , laboratory type induction coil, , series test lamp (rm), , knife switch dpdt fitted with fuse terminals (rm), , knife switch tpdt fitted with fuse terminals (rm), , miniature circuit breaker (rm), , earth plate (rm), , earth electrode (rm), , elcb and rccb (rm), , fuses (rm), , rheostat (sliding type), , capacitors (rm), , various electronic components (rm), , various lamps (rm), , plug socket piano switch lamp, , holder (rm), , cables:, , twisted pair, , non-metallic sheathed cable, , underground feeder cable, , ribbon cable, , metallic sheathed cable multi-, , conductor cable coaxial cable, , direct-buried cable (rm), , rubber mat (rm), , electrician helmet, , rcc pole with accessories (ms angle iron, 'c' clamp, stay insulator etc.) and materials, , quipment, , ohm meter; series type & shunt type, portable box type, , digital multi meter, , a.c. voltmeter m.i. analog, portable box type housed in bakelite case, , milli voltmeter centre zero analog, portable box type housed in bakelite case, , ammeter mc analog, portable box type housed in bakelite case, , ac ammeter mi, analog, portable box type housed in bakelite case, , weight wattmeter analog, , (b) frequency meter (digital), , magnetic flux meter, , tachometer, , tong tester / clamp meter, , megger, , single phase variable auto transformer, , growler, , ac starters: :- -, , f. star delta starter soft starter, , g. auto transformer type, , oscilloscope dual trace, , function generator, , discrete component trainer, , linear i.c. trainer, , digital i.c. trainer, , domestic appliances -, , g. mixture & grinder, , h. washing machine semi-automatic, , i. motor pump set, , oil testing kit, , battery charger, , current transformer, , potential transformer, , 1 5 or 17 computer or latest version, , d.c. shunt generator with control panel, , motor-generator (ac to dc) with control panel, , d.c. compound generator with control panel including fitted rheostat, voltmeter, ammeter and breaker, , dc series motor coupled with spring balance load with control pannel, , dc shunt motor with control pannel, , dc shunt motor with control pannel, , dc compound motor with starter and switch with control pannel, , motor generator(dc to ac) set consisting of - shunt motor with starting compensator and switch directly coupled to ac generator with exciter and switch board mounted with regulator, breaker, ammeter, voltmeter frequency meter, knife blade switch and fuses etc. set complete with cast iron bed, , plate, fixing bolts, foundation bolts and flexible coupling., , ac squirrel cage motor with star delta starter and triple pole iron clad switch fuse with mechanical load., , ac phase-wound slip ring motor with starter switch, , universal motor with starter/switch, , synchronous motor with accessories like starter, excitation arrangements., , thyristor /igbt controlled d.c., , motor drive with tacho-generator feedback arrangement, , thyristor/igbt controlled a.c. motor drive with, , single phase transformer, core type, air cooled, , three phase transformer, shell type oil cooled with delta/ star, , electrical machine trainer -, , diesel generator set with changeover switch, ov
Tender For supply of lab items for eee and mechanical - eee and mechanical lab items, single phase transformer rating: 1 kva, 50 hz input: 230 v ac output: 115 v ac type: air-cooled, single-phase step-down transformer properly insulated input and output terminals brought out for safe operation, three phase transformer type: three phase transformer rating: 3 kva input voltage: 415 v ac, 3-phase output voltage: 230 v ac, 3-phase frequency: 50 hz winding material: copper wound insulation class: class b or higher duty: continuous duty suitable for laboratory use bench/floormounted suitable for laboratory operation. all winding terminals shall be brought out to insulated terminals and enclosed within a protective outer cover for safe laboratory operation , on / off control of lamp using solid state relay kit type : solid state relay (ssr) trainer kit control/input voltage : 12 v / 24 v dc or up to 30 v dc output load voltage : 230 v ac, single phase load control : on/off control of ac lamp load solid state relay based switching circuit opto-isolated input control built-in ac lamp load manual on/off switching arrangement led indication for input and output status , mcb elcb trainer kit 1 phase/3 phase, 2/3/4 pole, 3a-16a single pole mcb 2-5amps two pole elcb 30ma lamp load single phase 5amps panel enclosure and terminal outlets , single phase induction motor kit for load test by speed control of vfd (variable frequency drive) 2 hp single phase 230v complete load test experimental setup(with brake drum/pulley) induction motor -1 no work bench setup with digital meter -1 no motor stand with ant vibration bush 1 set loading arrangement with spring balance non-vibrating brake arrangement with stand and electrical work bench , 3 phase induction motor kit three phase squirrel cage induction motor with rope brake arrangement non-vibrating brake arrangement with stand and electrical work bench three phase squirrel cage induction motor 5 hp, 440 v, 1440 rpm, foot mounted type, frame size 132 mm, core length 110 mm, mechanical rope loading set up with 1" screw rods 2 nos, 6" adjustable wheels 6" 2 nos, back support frame, 9" aluminium drum, 0 50 kg spring balances 2 nos , dc shunt motor kit for load test dc shunt motor rope brake arrangement non-vibrating brake arrangement with stand and electrical work bench d.c. shunt motor 5hp, 220v, 1500 rpm, foot mounted type, frame size 132 mm, core length 110 mm, field current 0.5a, armature current 11a, 4 pole with inter poles, mechanical rope loading set up with 1" screw rods 2 nos, 6" adjusting wheels 6" 2 nos, back support frame 9" aluminum drum, 0 50 kg spring balances 2 nos. , bldc motor kit with electrical work bench *36v 400w bldc pro motor 1 no inbuilt volt and ammeter and rpm meter inbuilt power supply input 230v ac
Tender For supply of modules chp a , overhauling, servicing of coal handling control room switch gear section b main bus chp a , overhauling,servicing of coal handling control room switch gear section b breaker ic, og, chp a , overhauling,servicing of coal handling control room switch gear section b panels chp a , overhauling,servicing of coal handling control room switch gear section b russian control modules chp a , overhauling,servicing of coal handling main building transfer point switch gear main bus transfer point section a, chp a , overhauling,servicing of coal handling main building transfer point of panels, chp a , overhauling,servicing of coal handling main building transfer point of russian control modules, chp a , overhauling,servicing of coal handling main building transfer point of switch gear main bus transfer point section. b, chp a , overhauling, servicing of coal handling main building transfer point of panels, chp a. , overhauling,servicing of wagon tippler, switch gear electrical wagon pusher sg room of russian breaker. , overhauling,servicing of wagon tippler, switch gear electrical wagon pusher sg room of russian resistance boxes a chp. , overhauling,servicing of wt sg sg room of wagon tippler resistance boxes, a chp. , overhauling,servicing of 0.4 kv swg sectiona, b, c, fhd swg section a, b and old and new stacker, reclaimer switch gear of chp a , overhauling, servicing of l.t. modules,panel of breaker ,ic coupler of chp, control room of bchp , overhauling,servicing of ltmodules panel of breaker ,og feeder of chp, control room of bchp , overhauling,servicing of ltmodules,panel of breaker , ic coupler of fuel handling control room of bchp , overhauling,servicing of ltmodules,panel of breaker ,og feeder of fuel, control room of bchp , overhauling,servicing of old stacker re claimer panel , overhauling,servicing of old stacker reclaimer resistance box of bchp , overhauling,servicing of old stacker reclaimer control panel of bchp , overhauling,servicing of new stacker reclaimer panel , overhauling,servicing of newstacker reclaimer resistance box of bchp , overhauling,servicing of newstacker reclaimer control panel of bchp , servicing,overhauling and breakdown maintenances of mimic plant of chp. , overhauling ,servicing of tippler switch gear of b chp. , overhauling,servicing of wagon tippler room operator panel on off of bchp , overhauling,servicing of wagon tippler room incoming power panel of bchp , overhauling,servicing of wagon tippler room control modules of bchp , overhauling or servicing of wagon tippler room resistance box of bchp , overhauling or servicing of wagon tippler screw pad overhauling of bchp. , overhauling or servicing of wagon tippler over travel limit switch otls overhauling of bchp. , overhauling or servicing of wagon tippler mcc panel of tipper 11a, 11b, 12a, 12b of bchp.
Tender For work of 415v ltmodule rewiring, tb replacement & retrofitting of protection relays at unit #3 during aoh/coh, as and when required at paras tps.
Tender For supply of transportation of material , erection of ltmodule , retrofitting work of panel , cable lying and clamping , end termination work of cable , earthing of lt panel , installation of lighting system , supply of mcc panel with incomer 4 pole 200a and 6 outgoing feeder with 25a rating , supply of cable 1.1kv, xlpe, 3.5c 120 sqmm al , supply of cable 1.1kv, xlpe, 4c 10 sqmm cu