Web Analytics Made Easy - StatCounter

Mast Light Tower Repair Tenders

Get complete information related to latest Mast Light Tower Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Mast Light Tower Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Mast Light Tower Repair Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :42136909 Due date: 28 Oct, 202528 Oct, 2025 59.09 Lacs
Tender For supply, erection, modifying & commissioning of lighting system at sikka tps. - copper cable 4 corex2.5 mm2,1100 volts annealed tinned copper cond.as per is 1554(part-i)/1988., copper cable 2 corex2.5 sqmm,1100 volts annealed tinned copper cond.as per is 1554(part-i)/1988., 20 amp. 240v spn industrial type socket outlet with 2 pole and earth metal enclosed plug top along with 20 amp. c series sp mcb in sheet steel enclosure on surface with chained metal cover for the socket out let., junction box, made from 18 gauge crca sheet powder coated 150 mm x 150 mm with 4 way connector and ip 54 protection, gi flexible pipe size: 20mm dia. heavy duty, steel conduit pipe size: 20mm dia. thickness-1.6 mm, gi ladder tray size 800 mm for cable, 4 way lighting distribution panel, mcb 16 amp,, mcb 3 phase,4 pole, 63 amp 440 v ac 50 hz 10 ka, 80-watt led lamps industrial well glassed luminari fixture, alluminium cable 3.1/2 corex35 sqmm lt, work of wiring, testing & commissioning of led flood/ well glass light fitting., laying charges for pvc armoured l.t. cable size (1-core to 4-core) 16mm2 to 95mm2 in cable tray/trench as per instruction of eic., work of connection, wiring & drawing of 4cx2.5/ 2cx1.5 mm2 size isi mark 1100 grade frls pvc insulated multi strand flexible copper including earth wire from lp to jb to luminaries & receptacles in existing steel conduits., work of fixing 20 amp. 240v spn industrial type socket outlet with 2 pole and earth metal enclosed plug top along with 20 amp. c series sp mcb in sheet steel enclosure on surface with chained metal cover for the socket out let., labor charges for removing existing lighting fixtures/ lamps with junction box/ fittings etc and to credit at main store., labor charges for removing existing wiring/ cables /conduits etc and to credit at main store., work of fixing, connection, testing and commissioning of lighting panel with 24/18 outgoing ckt. double door, insulated bus bar, insulated neutral bars, earth bar, cable ties, circuit identification labels., work of fixing, connection, testing and commissioning of mcbs (3 pole+ neutral) current rating 63amp in the above lp., work of fixing, connection, testing and commissioning of single pole mcb 16 amp in the above lp., work of fixing steel conduit 25 mm size, dia. 1.6 mm., work of installation of junction box, made from 18 gauge crca sheet powder coated 250 mm x 200 mm x 105 mm including all hardware like angle, support, cable gland and connector., work of installation of gi flexible pipe 25 mm dia. heavy duty to protect wiring from dust & moisture at lp & luminary termination., work of installation of hot dip galvanized cable tray size 200x50x50, 16swg isi standard make.

Central Government/Public Sector

CTN :42076544 Due date: 18 Oct, 202518 Oct, 2025 44.59 Lacs
Tender For name of work:- spl repair for conversion of overhead conductor with underground cable including connected items at 1806 pnr unit and hq cc (rvs) and provn of 8 x 1.5 ton hot and cool type split ac with voltage stailizer, electrical wiring for radiation oncology dept of ch (cc) under ge e/m lucknow

CTN :42123251 Due date: 21 Oct, 202521 Oct, 2025 NA
Tender For supply of wooden door , wooden decor panelling , window printed blind , sofa , center table set of 2 , center table , bean bag , side table , vending machine , tv unit , decor panelling behind tv unit , 3d decor panelling , carpet tile flooring , false ceiling , ceiling paint , wall paint , plants , pot , clock , 1.5 sqmm point wiring , 2.5 sqmm point wiring , cob lights , switchboard , plug points 5amp , plug points 15amp , 2ton ac , ac installation , led strip lighting , hanging light type a , hanging light type b , music system

CTN :42141418 Due date: 13 Oct, 202513 Oct, 2025 NA
Tender For supply of volt meter , amperemeter , hours meter , stoper cable , push button , oil pressure guage , mcb , ac indication bulb , oil filter , air filter , frequency meter , fan belt , fuel pipe , single element pump , wiring harness , power card , automatic voltage regulator

CTN :42139819 Due date: 13 Oct, 202513 Oct, 2025 NA
Tender For supply of vehicle spare parts e e - 215454601605 wiring harness main , 35100m80020 head lamp assy , 287083000201 ac compressor , b- 8763401 coolent pump assy , 2157-5440-0115 assy head lamp with halogen bulb rh , 2157-5440-0114 assy head lamp with halogen bulb lh , 280954440102 five chamber tail lamp 24v rh , 280954440101 five chamber tail lamp 24v lh , 31400m70f00 generator assy , 2505-2620-7804 oil seal , 2654-4310-0111 brake fluid container assy , 23710m83043 cable assy clutch , 2540-009295 rear view mirror lh , 145413 side stand assy , 6220-004598 traficator assy rh rear , 53200m83050 shoe set rear brake , 55810m70a00 pad , 340-331-0050 bush king pin , 2574- 3345-3104 tapper roller bearing front hub , 2574- 4215-0113 wheel cyl with citradelip , 43511m83003 rear drum brake , 22400m83060 disc clutch , 22100m83060 cover assy clutch , 3120-004922 bearing clutch release , 5340-135143 engine mounting pad , 3020-015963 sprocket comp cam chain guide , 45450-198-900 cable comp front brake , 22870-kcc-900 cable comp clutch , 44830-kst-940 cable comp speedometer , 17910-198-900 cable comp throttle , 4720-016125 hose non metalic , b-1211802 radiator and cac assy with shroud ) /bid number : gem/2025/b/6751966 * /dated: 03-10-2025 & & / bid document 1 / 24

CTN :42119742 Due date: 11 Oct, 202511 Oct, 2025 NA
Tender For supply of sitc of 100 percent inverter vrf units of capacity 28 hp complete all as specified in srl no 1 of appendix a , sitc of 100 percent inverter vrf units of capacity 16 hp complete all as specified in srl no 2 of appendix a , sitc of hiwall units of capacity 2 point 8 tonn complete all as specified in srl no 3 of appendix a , m and l for 4 core 16 sq mm xlpe insulated aluminum conductor heavy duty 1100 volt grade cable complete all as specified in srl no 4 of appendix a , m and l for galvanized steel earth plate electrode based earthing complete all as specified in srl no 5 of appendix a , s and f spn 32a mcb with steel metal enclosure complete all as specified in srl no 6 of appendix a , sitc of 5 kva voltage stabilizer complete all as specified in srl no 7 of appendix a , m and l for ac sub main wiring complete all as specified in srl no 8 of appendix a , s and f heavy duty copper pipe of size 15mm 5 oblique 8 inch dia complete all as specified in srl no 9 of appendix a , s and f heavy duty copper pipe of size 10mm 3 oblique 8 inch dia complete all as specified in srl no 10 of appendix a , s and f pvc drain pipes of suitable size 25 mm complete all as specified and directed by engr in charge , self - contained drinking water coolers (v3) as per is 1475 (q2) , split air conditioner including green ac, wall mount type (v2) (q2)

Central Government/Public Sector

CTN :41778790 Due date: 08 Oct, 202508 Oct, 2025 NA
Tender For supply of ac circuit breaker kit icu 100ka (eaton, gb14048.2, nzm4, 400/415vac, 50/60hz) , make: eaton , drive contactor (eaton, dilm17-10, xtceo18c10, 24-27dc with auxiliary nonc) , make: eaton , inductance ventilation set/ instrument cooling fan (ebmpapst, k3g280 rr04-i2, 1-200-277vac 50/60hz , harmonics filter 1000vdc of six nos of capacitor with wiring, each capacitor is atcotronics, , set motorized switch breaker 4p 2000a, 1051022762

Central Government/Public Sector

CTN :41826679 Due date: 10 Oct, 202510 Oct, 2025 48.00 Lacs
Tender For corrigendum : repair replacement of internal wiring electrical fittings fixtures renewal of building earthing other connected items in ro of otm accn at prtc 106 ta inf bn and repair replacement of us rusted ac ci gi pipe line including connected

State Government

CTN :42063721 Due date: 08 Oct, 202508 Oct, 2025 4.99 Lacs
Tender For tender for repair/replacement of damaged/defective equipments in control room/yard at various sub-stations under electrical system division hpsebl una - replacement of defective space heaters (230v ac, 40 watt) along with thermostate (1 for 2 heaters) (range 30 degree c - 85 degree c) at 66kv sub-station, gwalthai, replacement of industrial standard warm white 250 watt led light (make ;- crompton/ havells/ bajaj/ orient), high mast/ flood light, ip 65/ ip 66 compliant (one year onsite warranty) including fabrication of clamps, 2.5 sq mm cable wiring etc. as per the satisfaction of engineer in-charge at 132kv sub-station, una, replacement of industrial standard warm white 250 watt led light (make ;- crompton/ havells/ bajaj/ orient), high mast/ flood light, ip 65/ ip 66 compliant (one year onsite warranty) including fabrication of clamps, 2.5 sq mm cable wiring etc. as per the satisfaction of engineer in-charge at 132kv sub-station, amb, repalcement of control room defective led white tube light (cool whitle) 20 watt, supply voltage 220v ac (make: philips/ bajal/ crompton/panasonic) at 132kv sub-station, hpsebl amb, replacement of defective ceiling fan 1400 mm high speed 390 rpm, rust proof body supply voltage 220 v ac (make: philips/ bajal/ crompton/panasonic) at 132kv sub-station, hpsebl amb, replacement of defective 12-inch portable anti-rust exhaust fan, quiet & adjustable for any space 300 mm exhaust fan(make: philips/ bajal/ crompton/panasonic) for battery charging room at 132kv sub-station amb, replacement of defective 12 window microprocessor based alarm announciator, voltage-220 v dc (make minilec model 312b mp0 big window) at 33kv feeder panel at 132kv sub-station, hpsebl amb., replacement of defective indication lamp for c&r panel (red-15, green-15, white-5 yellow-5, blue-5) supply voltage-30v-240 v ac/dc at 132kv sub-station amb, repalcement of defective jvs tripping relay type jrv 171 voltage 220 v dc as per sample at 132kv sub-station amb, repalcement of defective jvs type tcsr relay jrv 111 voltage 220 v dc as per sample at 132kv sub-station amb, quantities are mentioned above are tentative and actual quantity shall be worked out .payment shall be made as per approved bill of material/actual quantities measured at site.

corporations/Associations/Others

CTN :41891779 Due date: 03 Oct, 202503 Oct, 2025 934
Tender For supply and installation of 85kw ongrid solar rooftop power plant and 5 years maintenance at swm site, yadapura road, arsikere cmc limit - bos-balance of system & integrating with dashboard for real-time energy production monitoring, grid & battery performance tracking, iot-based remote monitoring & control, smart alerts & predictive maintenance, historical data & performance analytics,web & mobile dashboard access, three phase bidirectional smart energy meter and escom energy meter approval charges, application charges, agreement making and synchronization, installation of aluminum rails, solar panels and inverters. wiring from panels to dcdb, dcdb to inverter, inverter to acdb, acdb to lt panel, panel to panel loop earthing, dc earthing, ac earthing and light ninga rrest or flatlaying. and comprehesive maintenance for 5 years, aluminumrailstructure,longrailorshortrailstructurefor panel mounting. end clamps and mid clamps mounting structure using spring nut and all enboltfasteners.rivetingforeach rail with epdm layer for water leak protection., provision and installation of hot-dip galvanized earthing flats, fabricated from is 2062 grade steel with 80 100 micron zinc coating for long-term corrosion resistance. the conductor arrangement includes standard 25x6 mm gi earth flat (center folded) as the main earth conductor, along with 25x3 mm gi flat as auxiliary earthing strip, deployed for interconnection of solar inverters, modules, and distribution panels to the common earthing network, design, supply, and installation of maintenance-free chemical earthing system comprising a 3-meter long, 17.2 mm dia copper-bonded electrode with 250-micron coating. the electrode is provided with backfill compound for enhanced soil conductivity and long-term stability, ensuring low-resistance grounding suitable for rooftop pv installations and associated electrical equipment protection., provision and installation of solar-grade flexible copper earthing conductor, made from high-conductivity copper (is 8130 1984 compliant) with uv-stabilized pvc insulation for outdoor durability. includes 1.1 kv, 1cx6 sq.mm green-yellow coded cable, deployed for module mounting structure and panel earthing to ensure reliable system grounding and enhanced safety in rooftop pv installations, provision and installation of solar-grade flexible copper earthing conductor manufactured from high-conductivity copper (is 8130 1984 compliant) with uv-stabilized pvc insulation. includes 1.1 kv, 1cx6 sq.mm green-yellow coded cable, deployed for module mounting structure and panel earthing to ensure reliable grounding and electrical safety in rooftop pv systems., provision and installation of solar grade flexible copper earthing conductor, manufactured from high-conductivity copper is 8130 1984 compliant, insulated with uv-stabilized pvc for long-term rooftop exposure. includes 1.1 kv, 1cx6 sq.mm green-yellow coded cable, specifically designated for inverter body earthing and safety bonding within the pv system, provision & installation of frls xlpe insulated 1.1 kv aluminum conductor h4 grade, stranded class-2 power cable, optimized for solar inverter to acdb interconnection. cable construction includes black extruded xlpe inner sheath is 5831 compliant, with galvanized steel armoring providing 90% coverage for enhanced mechanical protection, designed in accordance with is 1554/iec 60189. scope covers 4c x 25 sq.mm a2xfy cable routing and termination, integrated into rooftop photovoltaic ac distributio, custom-provision and installation of solar pv compliant dc cabling system comprising tuv-certified 1.5 kv electron-beam cross-linked xlpo insulated copper conductors with uv-resistant sheath. scope includes color-coded red and black 1cx4 sq.mm cables, optimized for rooftop photovoltaic string interconnections, supply and installation 8-in8-out dcdb1000vdc,ip65,iec certified, iot-compatible for remote monitoring voltage and current , ip 65 enclosur
 Loading, Please wait...

Connect us via What's Up