Get complete information related to latest Master Trip Relay Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Master Trip Relay Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Master Trip Relay Tenders.
Tender For supply and installation of numerical o/c and e/f relay, differential relay and mastertriprelay of 66kv and 11kv panel of 66/11 dalwada sub-station for upgradation of protection functions and enable scada operation
Tender For bid to ras corrigendum : supply of service 11 kv ht panel as per sepcifications , sf new mineral oil for panel etc as per sepcifications , calibration relay etc as per sepcifications , replacement digital ammeter for ht panel , replacement digital voltmeter for ht panel , replacment ryb ind lamp led type in ht panel , sf 2a hrc fuselink in ht panel , servicing 1500kva dry type transformer as per sepcifications , servicing 2 runs 2500a tpn bustrunking as per sepcifications , service mv lt panel with 2500a 4p acb 3 nos as per specifications , service mvlt panel with mccb incoming as per specifications , checking and repair of em intelocking , dismentaling 3.5 sq mm 240 or 300 sq mm al cable as required , pf adaptor box aprx 1.5 ft x 1.5 ft x 1.5ft of 16swg ms sheet as reqd , pvdg panel module door key as reqd , pvd and fixing operating handle for 250a 4p changeover as reqd , replacement 160a hrc fuse with base in extg cap panel , replacement 3p 50kvar cap duty contactor in extg cap panel , replacement 25sq mm cu lead wire 1ft length in extg cap panel , checking etxg 2no 25kvar cap bank and fault repair reinstallation , dismentaling uv protection connections as reqd , replacement digital ammeter for lt panel , replacement digital voltmeter for lt panel , replacment selector switch in lt panel , replacment ryb ind lamp led type in lt panel , sf 2a hrc fuselink in lt panel , sf 32a hrc fuseling incl removing faulty item from lt panel as reqd , sf 63a hrc fuseling incl removing faulty item from lt panel as reqd , sf 100a or125a hrc fuseling incl removing faulty item from lt panel as reqd , sf 250a hrc fuseling incl removing faulty item from lt panel as reqd , sf new 5 or 6 amp piano switch in replacement of faulty item , sf new 5 or 6 amp 3pin socket outlet in replacement of faulty item , sf new 15 or 16 amp piano switch in replacement of faulty item , sf new 15 or 16 amp 6pin socket outlet in replacement of faulty item , rewinding ceiling fan motor , sf 4ft 20w led fitting against faulty fitting , service of 750kva dg set as per specification , service dgset control panel 1250a 4p acb as per specification , repacement ryb ind lamp in dg set panel , repacement digital ammeter in dg set panel , earthing testing in existing earth pits and report submission
Tender For supply and replacement of defective parts of kirloskar make transformers of 1000/750/500 kva capacity at ugc & cag building, new delhi. - supply and fixing of over current earth fourth relay 24 dc l&t make etc complete as reqd. , supply and fixing of 11 kv indoor single phase resin cast current transformer 300/5amp etc complete as reqd., , supply and fixing of transformer 500 kva 11/0.433 kv wt1 scanner & rtd sencer lead., , supply & installation of suitable rating of 500 kva 11/0.433 kv lv bussing porcelain or epoxy-cast resin comply with is-1180 complete as required, , supply and fixing of suitable rating of 500 kva 11/0.433 kv lv flexible porcelain or epoxy-cast resin comply with is-1180 complete as required., , dismantling /loading and unloading of 500kva, 11kv/433volt, 3phase, 50hz, cast resin dry type kirloskar make indoor transformer hv/lv coil/core etc and repair of crack in hv/lv winding/core and putting cast resin/resin hardener, reassembling all the dismantle parts accessories confirming to is 11171 and iec 60076 etc including all tests i.e voltage ratio, magnetic balancing, vector group, ir magnetizing current, winding resistance etc complete as reqd., , supply & installation of 630a vcb vacuum interrupter etc complete as reqd., , sh-2 (old cag bldg), , supply and replacement of 750- 1000 kva transformer oil gas kit etc complete as reqd., , checking in 750-1000 kva transformer all type of protection etc complete as reqd., , supply and replacement of lv bushing oil seal in 750-1000 transformer etc complete as reqd. no.ryb) (4, , supply and replacement of hv bushing oil seal in 750-1000 transformer etc complete as reqd. (3 no. r,y, b), , supply and replacement of off load tape changer in 750-1000 kva transformer etc complete as reqd., , replacement of transformer oil in oltc top-up of main tank etc complete as reqd., transformer oil filtration and dehydration of 750 kva & 1000 kva transformer using high-vacuum oil filtration plant, including removal of moisture, dissolved gases, sludge and impurities from transformer oil, circulation of oil through filtration machine, achieving required bdv value, testing before and after filtration, manpower, tools & tackles, consumables, complete as required at site., , complete servicing, overhauling, cleaning, contact checking, lubrication, insulation resistance testing, contact resistance testing, functional testing and commissioning of oil circuit breaker (ocb), complete as required at site., , supply & installation of male contact, , supply & installation of female contact, , supply & installation of over current earth fault relay, , supply & installation of 24 volt dc power pack unit etc complete as reqd., , supply and fixing of transformer wti relay etc complete as reqd.., , supply and replacement of transformer oti relay etc complete as reqd.., , providing and fixing following rating and breaking capacity and pole mccb with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, ics=100% icu and operational voltage 690v etc. as required., , (make: schneider electric-nsx /siemens / lk/ abb/hager)
Tender For corrigendum : supply of electrical spares c c > f> f - mastertriprelay , side cable box , power converter 110v ac to 110v dc , digital protection relay , epoxy resin cast current transformer
Tender For corrigendum : providing and fixing of mastertriprelay and aux. relay in candr panel (nelumbo make) of 220 kv sarangapur (pgcil)- jhusi line at 220 kv substation jhusi, under electy. trans. division-i, prayagraj
Tender For corrigendum : : work of maintenance of various equipment’s at 33 kv control panel/ vcb/line isolator including retro fitting of damaged protection relay and maintenance & repair work of 11 kv vcb along with erathing of power t/f & control room & inreacting capcity of power t/f (at 33/11 kv quila s/s) etc. in different 33/11 kv s/s under 33 kv vertical, bareilly for system strengthening for providing uninterrupted 24*7 power supply under the head of (b.p. 2025-2026).
Tender For providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - supply of restricted earth fault protection relay type mcom p642 with auxiliary protection wti/oti/prv/osr/buchholz/oltc prv triprelay abb/siemens & similar make as per samples/site requirement.