Get complete information related to latest Master Trip Relay Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Master Trip Relay Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Master Trip Relay Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :45711090 Due date: 03 Jul, 202603 Jul, 2026 NA
Tender For spare parts of scania - connector 1/4" part no 140523, oil collector part no 257319, hand brake valve part no 249914, switch, foot dipper part no 159656, stop light switch part no 158717, t-connector part no 229020, air dryer part no 258985, charging valve part no 215619, elbow connector part no 146235, elbow connector part no 229704, pressure regul. valve part no 5360042991(230787), safety valve part no 293542, valve seat part no 229358, repair kit part no 263664, repair kit part no 263667, bumper part no 249727, stop part no 217280, contact holder part no 235650, sliding contact part no 130770, cap lower part part no 1102372, cap upper part part no 1102371, oil container part no 197804, hydraulic oil pump part no 259310, relay part no 371912, comp circuit part no 259240, relay part no 173554, block terminal part no 353489, socket part no 255080, starting socket part no 231631, battery main switch part no 197811, gear selector (gear box) part no 6695000734(393779), gear selector (transfer box) part no 5895022571(393777), tandom driving cable part no 1149732, bulb 2w/24v part no 258491, panel, switches part no 248821, panel, control lamps part no 248820, map reading lamp part no 218412, control lamp oil pressure part no 239170, control lamp full beam part no 239173, light filter part no 246680, control lamp (direct indicator i) part no 239174, control lamp (gear box oil temp) part no 255073, control lamp coolant temp part no 246856, control lamp (reversing light) part no 249300, plate, blackout lighting part no 391567, techometer part no 258660, comb instrument part no 268353, oil pressure gauge part no 259794, water temp gauge part no 249108, fuel gauge part no 249109

CTN :45701761 Due date: 07 Jul, 202607 Jul, 2026 NA
Tender For supply and installation of numerical o/c and e/f relay, differential relay and master trip relay of 66kv and 11kv panel of 66/11 dalwada sub-station for upgradation of protection functions and enable scada operation

Central Government And Public Sector

CTN :45279869 Due date: 29 Jun, 202629 Jun, 2026 2.90 Lacs
Tender For bid to ras corrigendum : supply of service 11 kv ht panel as per sepcifications , sf new mineral oil for panel etc as per sepcifications , calibration relay etc as per sepcifications , replacement digital ammeter for ht panel , replacement digital voltmeter for ht panel , replacment ryb ind lamp led type in ht panel , sf 2a hrc fuselink in ht panel , servicing 1500kva dry type transformer as per sepcifications , servicing 2 runs 2500a tpn bustrunking as per sepcifications , service mv lt panel with 2500a 4p acb 3 nos as per specifications , service mvlt panel with mccb incoming as per specifications , checking and repair of em intelocking , dismentaling 3.5 sq mm 240 or 300 sq mm al cable as required , pf adaptor box aprx 1.5 ft x 1.5 ft x 1.5ft of 16swg ms sheet as reqd , pvdg panel module door key as reqd , pvd and fixing operating handle for 250a 4p changeover as reqd , replacement 160a hrc fuse with base in extg cap panel , replacement 3p 50kvar cap duty contactor in extg cap panel , replacement 25sq mm cu lead wire 1ft length in extg cap panel , checking etxg 2no 25kvar cap bank and fault repair reinstallation , dismentaling uv protection connections as reqd , replacement digital ammeter for lt panel , replacement digital voltmeter for lt panel , replacment selector switch in lt panel , replacment ryb ind lamp led type in lt panel , sf 2a hrc fuselink in lt panel , sf 32a hrc fuseling incl removing faulty item from lt panel as reqd , sf 63a hrc fuseling incl removing faulty item from lt panel as reqd , sf 100a or125a hrc fuseling incl removing faulty item from lt panel as reqd , sf 250a hrc fuseling incl removing faulty item from lt panel as reqd , sf new 5 or 6 amp piano switch in replacement of faulty item , sf new 5 or 6 amp 3pin socket outlet in replacement of faulty item , sf new 15 or 16 amp piano switch in replacement of faulty item , sf new 15 or 16 amp 6pin socket outlet in replacement of faulty item , rewinding ceiling fan motor , sf 4ft 20w led fitting against faulty fitting , service of 750kva dg set as per specification , service dgset control panel 1250a 4p acb as per specification , repacement ryb ind lamp in dg set panel , repacement digital ammeter in dg set panel , earthing testing in existing earth pits and report submission

State Government

CTN :45654593 Due date: 12 Jul, 202612 Jul, 2026 NA
Tender For procurement of various electromagnetic and auxiliary relays during unit #3 aoh/coh at paras tps. - mvapm32d1aa2001a aux 220vdc rated 110vac, auxi/cntrl 220 vdc relay vaa11yf8752ca, aux/control 220 vdc relay vaa11yf0752ba, cntrl 220vdc ee/areva vaa-21 zg 8502 fch, relay genprot vaa 21bf 8055 f (m), aux/ctrl v220dc relay vaa-11 yf 8407 fch, aux/ctrl v220dc relay vaa-33 zg 8314f(m) ., relay 30vdc ee/are vag11yf8018 hch u v ,mprvajh 23zg8003bch master trip relay, relay 220 vdc ee / areva vajhm53sf127d, cntrl 220vdc ee/arev vajc-11 zf 8304 ach, vawa12yf8005dch aux 220vdc 4no, cntrl 220vdc ee/areva vax-31 zg 8075bch, relay x-mer protn vtt12zg8100bch dtr del.

State Government

CTN :45503599 Due date: 02 Jul, 202602 Jul, 2026 83.0 Thousand
Tender For corrigendum : providing and fixing of master trip relay and aux. relay in candr panel (nelumbo make) of 220 kv sarangapur (pgcil)- jhusi line at 220 kv substation jhusi, under electy. trans. division-i, prayagraj

CTN :45419248 Due date: 01 Jul, 202601 Jul, 2026 NA
Tender For corrigendum : supply of electrical spares c c > f> f - master trip relay , side cable box , power converter 110v ac to 110v dc , digital protection relay , epoxy resin cast current transformer

CTN :45415159 Due date: 25 Jun, 202625 Jun, 2026 4.58 Lacs
Tender For corrigendum : repair and maintenance of tube wells and boosters including repair of water level gauge, ms panel, sluice valves and allied items of civil / electrical at various buildings i.e. punjab raj bhawan, haryana raj bhawan & residence sector-7, under maintennace booth, sector-7, chandigarh. (ch to: 2216 (np) mtc. and repair ) - repair of ci sluice valve up to 150 mm dia including dismantling, repair / replacement of spindle, nut , rubber packing, nuts and bolts complete., up to 100 mm dia, lifting and lowering of submersible pump set including dismantling of flenged joints, taking out column pipes, re-jointing etc including replacement of defective packing, nuts and bolts etc complete, tube well, booster, supplying and fixing of single phase preventor make minilec or equivalent model of approved make to the satisfaction of eic , supplying and fixing of current transformer ( ct ) for ampere meter of suitable rating complete., supplying and fixing of overload relay of following capacities, 14 to 23 amp, 30 to 42 amp, 45 to 75 amp, providing and fixing of star delta starter timer of make l&t or equivalent model of approved make to the satisfaction of eic, providing and fixing of kit kat 500 amp complete in all respect, supplying and fixing of capacitor of 20 to 50 mfd make l&t, siemens or equivalent model of approved make to the satisfaction of eic , supplying and fixing of analog meter of make l&t ( rishabh ) or equivalent model of approved make to the satisfaction of eic , volt meter, ampere meter, supplying and fixing of 3 pole mccb of following capacity of make l&t, bch, havells or equivalent model of approved make to the satisfaction of eic , 100 amp, supplying & fixing of contactors block of make l&t, bch or equivalent model of approved make to the satisfaction of eic , mnx - 25, mnx - 32, mnx - 50, mnx - 70, supplying and lowering of submersible cable 16mm2 of make havells, finolex, l&t or equivalent model of approved make to the satisfaction of eic , supplying and lowering of submersible cable 25mm2 of make havells, finolex, l&t or equivalent model of approved make to the satisfaction of eic , providing and fixing hydro pneumatic pump of size 0.5 hp of approved make with 24 ltr capacity tank, pressure switch, pressure gauge, nrv accessories and making connections complete of make crompton or equivalent model of approved make to the satisfaction of eic, repair and rewinding of submersible pump set including carriage from installation to workshop and back. the rate include replacement of all defective parts of pump and motor rewinding., 5 hp, 7.5 to 10 hp, 35 hp to 55 hp, repair and rewinding of monoblock submersible pumping set including repacement of defective parts as required and carriage from installation to workshop and back., 0.5 h.p, 1 h.p, 2 h.p, manufacturing, supplying and fixing of ms control panel 16 gauge of size 600x700mm with door including wiring of inside panel, complete in all respect, providing and fixing of self pumping monoblock single phase pump for boosting of make crompton or equivalent model of approved make to the satisfaction of eic, 0.5 h.p, 1 h.p, 2 h.p, providing and fixing of pressure gauge make h-guru or equivalent model of approved make to the satisfaction of eic, providing and fixing of elcb 63 amp make l&t/havells or equivalent model of approved make to the satisfaction of eic, repair of internal control wiring 1.5mm wire with thimbles, nut bolt etc. complete

CTN :45627469 Due date: 21 Jun, 202621 Jun, 2026 NA
Tender For procurement of automation spares 3-way ball valve. size-dn15. body-cf8, 12/50 bar , s-20, p#14102145. s#1a00r53731k, 0-40 bar, 4-20ma, 8-35v , power supply unit, pro eco 960w 24v 40a, 100-240v ac/dc 240w weidmuller , hmi/computer. tpc-1251t/tpc-1551t, input 24vdc, 1.9a for tpc-12511/1.7a for tpc-1551t, adwantech , display unit, ddu-tm, 90v to 264v ac. ip-65 wall mounted. masibus , digital output module, do524, a5, 32do-transister, ip-20, abb , trip coil supervision relay. mvaxm31d1ce3005a, 2no+ inc special repair contacts, 220-250v dc. alstom , master trip relay, vajhm23zg1002bba, contact-8 n/o, 2n/c h/r. 220-250v dc (48w & 8w for gtrmp, 32w for line, 40w for tagp) 03 no each. alstom , synchronous cope with check sync relay. sq 0214, pt input-110v ac, iskara , auto synchronizer. spm-d2-10/n, 120-375v dc. woodward , guard relay. vaa21zg0750ba, vaa21, 220v dc, alstom , micom p111. p111-l, 24-240v ac/dc, schneider , speed monitor with card, k3hb-rnb, 24v ac/dc, in=1a/5a,lon=1a/5a, omron , position indicator, 409, 85-265v ac/100-300v dc, input 4-20 ma. masibus , lockout relay, rxmvb4, 220v dc, abb , speed module, 1401, 24v dc, jaquet , power supply. p.or-24-40, 24 v dc, paramount , trip coil supervision relay, 7pj13215aa210aa0, 18-265v ac/dc, siemens , field breaker trip coil, 220v dc, mersen , field breaker closing coil, 220v dc, mersen , field current measurement transducer, 20-30 v dc, output 4-20ma, input 0-60mv dc , field voltage measurement traprducer bd1-50135 , dc emergency valve with coil, 220v dc, atos , kw transducer, ctr-2500/5a, range 0-45 mw, 220v dc, 0.5 class, dual o/p-4-20 ma, rishab , frequency transducer with display, 0.2 class, dual o/p-4-20 ma. 110 v ac. rishab , interposing voltage transformer, ratio-110v/110v ac, primary/sec delta/star dyn11, burden-50va, 0.5 class, kalpa , reversing voltage transformer, ratio-110v/110v ac, burden-50 va, o/v factor-1.2 continuous, 0.5 class, kalpa , dc aux. contactor, 220v dc, 4no +4nc 9amp. abb , ac aux. contactor, 110vac,4no +4nc 9amp. abb , dc aux. contactor. 220v dc. 2no +2nc 16amp. abb

CTN :45627473 Due date: 21 Jun, 202621 Jun, 2026 NA
Tender For procurement of automation spares 3 way ball valve. size-dn15. body-cf8, 12/50 bar , s-20. p#14102145. s#1a00r53731k, 0-40 bar, 4-20ma, 8-35v , power supply unit. pro eco 960w 24v 40a, 100-240v ac/dc 240w weidmuller , hmi/computer. tpc-1251t/tpc-1551t, input 24vdc. 1.9a for tpc-12517/1.7a for tpc-1551t. adwantech , display unit, ddu-tm. 90v to 264v ac. ip-65 wall mounted, masibus , digital output module, do524, a5, 32do-transister. ip-20, abb , trip coil supervision relay. mvaxm31d1ce3005a, 2no+ inc special repair contacts, 220-250v dc, alstom , master trip relay, vajhm23zg1002bba, contact-8 n/o, 2n/c h/r. 220-250v dc (48w & 8w for gtrmp, 32w for line, 40w for tagp) 03 no each, alstom , synchronous cope with check sync relay, sq 0214, pt input-110v ac, iskara , auto synchronizer, spm-d2-10/n, 120-375v dc, woodward , guard relay, vaa21zg0750ba, vaa21, 220v dc, alstom , micom p111, p111-l, 24-240v ac/dc, schneider , speed monitor with card, k3hb-rnb, 24v ac/dc. in=1a/5a.lon=1a/5a, omron , position indicator, 409, 85-265v ac/100-300v dc, input 4-20 ma, masibus , lockout relay, rxmvb4, 220v dc, abb , speed module, 1401, 24v dc, jaquet , power supply, p.or-24-40, 24 v dc, paramount , trip coil supervision relay, 7pj13215aa210aa0, 18-265v ac/dc, siemens , field breaker trip coil, 220v dc, mersen , field breaker closing coil, 220v dc, mersen , field current measurement transducer, 20-30 v dc, output 4-20ma, input 0-60mv dc , field voltage measurement transducer, pd1-50135. accuracy= +-5%, 24v dc, op-1-4-20 ma dc,op-2-2-10vdc, input 0-500v dc, ae , mccb 2-pole 100 amp. , dc emergency valve with coil. 220v dc. atos , kw transducer, ctr-2500/5a, range 0-45 mw, 220v dc. 0.5 class. dual o/p-4-20 ma, rishab , frequency transducer with display, 0.2 class, dual o/p-4-20 ma, 110 v ac, rishab , interposing voltage transformer, ratio-110v/110v ac, primary/sec delta/star dyn11, burden-50va, 0.5 class, kalpa , reversing voltage transformer, ratio-110v/110v ac, burden-50 va, o/v factor-1.2 continuous, 0.5 class, kalpa , dc aux. contactor, 220v dc, 4no +4nc 9amp. abb , ac aux. contactor, 110vac,4no +4nc 9amp, abb , dc aux. contactor, 220v dc, 2no +2nc 16amp, abb

CTN :45344756 Due date: 22 Jun, 202622 Jun, 2026 30.00 Lacs
Tender For corrigendum : : work of maintenance of various equipment’s at 33 kv control panel/ vcb/line isolator including retro fitting of damaged protection relay and maintenance & repair work of 11 kv vcb along with erathing of power t/f & control room & inreacting capcity of power t/f (at 33/11 kv quila s/s) etc. in different 33/11 kv s/s under 33 kv vertical, bareilly for system strengthening for providing uninterrupted 24*7 power supply under the head of (b.p. 2025-2026).