Get complete information related to latest Mccb Panel Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Mccb Panel Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Mccb Panel Tenders.
Tender For supply and replacement of defective parts of kirloskar make transformers of 1000/750/500 kva capacity at ugc & cag building, new delhi. - supply and fixing of over current earth fourth relay 24 dc l&t make etc complete as reqd. , supply and fixing of 11 kv indoor single phase resin cast current transformer 300/5amp etc complete as reqd., , supply and fixing of transformer 500 kva 11/0.433 kv wt1 scanner & rtd sencer lead., , supply & installation of suitable rating of 500 kva 11/0.433 kv lv bussing porcelain or epoxy-cast resin comply with is-1180 complete as required, , supply and fixing of suitable rating of 500 kva 11/0.433 kv lv flexible porcelain or epoxy-cast resin comply with is-1180 complete as required., , dismantling /loading and unloading of 500kva, 11kv/433volt, 3phase, 50hz, cast resin dry type kirloskar make indoor transformer hv/lv coil/core etc and repair of crack in hv/lv winding/core and putting cast resin/resin hardener, reassembling all the dismantle parts accessories confirming to is 11171 and iec 60076 etc including all tests i.e voltage ratio, magnetic balancing, vector group, ir magnetizing current, winding resistance etc complete as reqd., , supply & installation of 630a vcb vacuum interrupter etc complete as reqd., , sh-2 (old cag bldg), , supply and replacement of 750- 1000 kva transformer oil gas kit etc complete as reqd., , checking in 750-1000 kva transformer all type of protection etc complete as reqd., , supply and replacement of lv bushing oil seal in 750-1000 transformer etc complete as reqd. no.ryb) (4, , supply and replacement of hv bushing oil seal in 750-1000 transformer etc complete as reqd. (3 no. r,y, b), , supply and replacement of off load tape changer in 750-1000 kva transformer etc complete as reqd., , replacement of transformer oil in oltc top-up of main tank etc complete as reqd., transformer oil filtration and dehydration of 750 kva & 1000 kva transformer using high-vacuum oil filtration plant, including removal of moisture, dissolved gases, sludge and impurities from transformer oil, circulation of oil through filtration machine, achieving required bdv value, testing before and after filtration, manpower, tools & tackles, consumables, complete as required at site., , complete servicing, overhauling, cleaning, contact checking, lubrication, insulation resistance testing, contact resistance testing, functional testing and commissioning of oil circuit breaker (ocb), complete as required at site., , supply & installation of male contact, , supply & installation of female contact, , supply & installation of over current earth fault relay, , supply & installation of 24 volt dc power pack unit etc complete as reqd., , supply and fixing of transformer wti relay etc complete as reqd.., , supply and replacement of transformer oti relay etc complete as reqd.., , providing and fixing following rating and breaking capacity and pole mccb with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, ics=100% icu and operational voltage 690v etc. as required., , (make: schneider electric-nsx /siemens / lk/ abb/hager)
Tender For work of s.i.t.c. of 125/200a mccbpanel on 63 kva dtrs and 200/250a mccbpanel on 100 kva dtrs in various location in 33/11 kv s/s lalpur on turnkey basis under edsd kichha rural under edd kichha
Tender For corrigendum : e-tender for rate contract for supply of electrical items - closing release, uc release -, universal motor for breaker spring charge, shunt release, l.a.f.a.p ,for castell lock: u-power, micro switch for spring charging, kwh meter, kwh meter, led a meter, led a meter, led volt meter, maximum demand controller, phase loss + phase sequence (smr), aux. contactor with ac coil, aux. contactor with ac coil, emergency stop button, modular , no contact block, selector switch, white led indicating lamp, blue led indicating lamp, green led indicating lamp, yellow led indicating lamp, amber led indicating lamp, red led indicating lamp, white led indicating lamp, blue led indicating lamp, green led indicating lamp, yellow led indicating lamp, amber led indicating lamp, red led indicating lamp, hotter, 230v ac, neutral link, control terminals, 1pole ac instantaneous high stability circulating current relay, micro processor based release, acc spreader terminal, aux contact, extended rotary handle, microprocessor based released, acc spreader terminal, microprocessor based released, acc spreader terminal, mccb with ti release, microprocessor based released, aux contactor with dc coil, timer, mccb with mp based release, extended rotary handle for above mccb, panel door mounted key lock for extended rotary handle, ct shorting terminals, closing release, uc release -, universal motor for breaker spring charge, shunt release, l.a.f.a.p ,for castell lock: u-power, micro switch for spring charging, kwh meter, kwh meter, led a meter, led a meter, led volt meter, maximum demand controller, phase loss + phase sequence (smr), aux. contactor with ac coil, aux. contactor with ac coil, emergency stop button, modular , no contact block, selector switch, white led indicating lamp, blue led indicating lamp, green led indicating lamp, yellow led indicating lamp, amber led indicating lamp, red led indicating lamp, white led indicating lamp, blue led indicating lamp, green led indicating lamp, yellow led indicating lamp, amber led indicating lamp, red led indicating lamp, hotter, 230v ac, neutral link, control terminals, 1pole ac instantaneous high stability circulating current relay, micro processor based release, acc spreader terminal, aux contact, extended rotary handle, microprocessor based released, acc spreader terminal, microprocessor based released, acc spreader terminal, mccb with ti release, microprocessor based released, aux contactor with dc coil, timer, mccb with mp based release, extended rotary handle for above mccb, panel door mounted key lock for extended rotary handle, ct shorting terminals
Tender For tender for supply of panel mounted mccbs - panel mounted mccb rated current- 63amps no. of poles- 03 ultimate short circuit breaking capacity(icu)at 415vac50/60 hz- 35ka or better service breaking capacity(ics)- 100% of icu adjustable overload and adjustable short circuit setting for line protection adjustable thermal and adjustable magnetic protection , panel mounted mccb rated current- 100amps no. of poles- 03 ultimate short circuit breaking capacity(icu)at 415vac50/60 hz- 35ka or better service breaking capacity(ics)- 100% of icu adjustable overload and adjustable short circuit setting for line protection adjustable thermal and adjustable magnetic protection , panel mounted mccb rated current- 125amps no. of poles- 03 ultimate short circuit breaking capacity(icu)at 415vac50/60 hz- 35ka or better service breaking capacity(ics)- 100% of icu adjustable overload and adjustable short circuit setting for line protection adjustable thermal and adjustable magnetic protection , panel mounted mccb rated current- 160amps no. of poles- 03 ultimate short circuit breaking capacity(icu)at 415vac50/60 hz- 35ka or better service breaking capacity(ics)- 100% of icu adjustable overload and adjustable short circuit setting for line protection adjustable thermal and adjustable magnetic protection , panel mounted mccb rated current- 250amps no. of poles- 03 ultimate short circuit breaking capacity(icu)at 415vac50/60 hz- 35ka or better service breaking capacity(ics)- 100% of icu adjustable overload and adjustable short circuit setting for line protection adjustable thermal and adjustable magnetic protection
Tender For corrigendum : supply, installation, testing and commissioning of new mccbpanel board in ug ladies hostel, g plus 2 new pg ladies hostel g plus 3 family welfare boys pg hostel g plus 1 new boys pg hostel g plus 3 ngh house staff hostel g plus 2 cardiology building g of scbmc and h, cuttack