Get complete information related to latest Mccb Panel Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Mccb Panel Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Mccb Panel Tenders.
Tender For supply of electro-mechanical & instrumentation items for mass balancing reservoir (mbr- supply of pump starter panel including individual vfd for 125 kw (02w+1s), supply of 1.1 kv grade cable- aluminium conductor supply, laying, testing & commissioning 1.1 kv grade, xlpe insulated, stranded aluminium conductor cables, a) 3.5 c x 185 sq.mm, b) 3.5 c x 300 sq.mm, 1.1 kv grade, xlpe insulated, stranded copper conductor, galvanised steel flat strip / round wire armoured, extruded pvc type st2 sheathed, heavy duty cable, a) 3 c x 2.5 sq.mm, supply of gi perforated type cable trays with returned edge / flange, fabricated from 2.0 mm thick sheet steel in the standard length of 2.5 mtrs, duly hot dipped galvanized after fabrication as per is 2629-1989 / is 4759-1984 including accessories such as coupler plates/ fish plates, bends, tees, reducers, elbows, covers and electro-galvanized hardware etc, erected on existing support as per specification, a) 450(w) x 75(h) x 2.0 mm thick, b) 300(w) x 35(h) x 2.0 mm thick, c) 100(w) x 35(h) x 2.0 mm thick, mechanical items, supply of di pipes k-9, dia 500mm, di fittings 500mm, , , , , , for 300 mm dia butterfly valve, for 500 mm dia butterfly valve, for 600 mm dia butterfly valve, instrumentation items, non-return valve 300 mm dia, , , , supply 10cx 1.5 sq.mm signal cable, supply 1px 1.5 sq.mm signal cable, supply 2cx 1.5 sq.mm signal cable, supply horizontal end suction pump 780m3/hr @40m head, impeller: ss, shaft: ss, casing: ci including pumps with mechanical seal. 120 kw 2w+ 1s, supply of 1/2" pressure gauge 0-10 bar,, supply of butterfly valve, supply of electric actuator, supply of electromagnetic flow meter 500 mm dia, supply of expansion bellow, supply of pressure transmitter, 0-7 kg/cm2,, supply of zero velocity valve 500mm dia
Tender For corrigendum : e-tender for rate contract for supply of electrical items - closing release, uc release -, universal motor for breaker spring charge, shunt release, l.a.f.a.p ,for castell lock: u-power, micro switch for spring charging, kwh meter, kwh meter, led a meter, led a meter, led volt meter, maximum demand controller, phase loss + phase sequence (smr), aux. contactor with ac coil, aux. contactor with ac coil, emergency stop button, modular , no contact block, selector switch, white led indicating lamp, blue led indicating lamp, green led indicating lamp, yellow led indicating lamp, amber led indicating lamp, red led indicating lamp, white led indicating lamp, blue led indicating lamp, green led indicating lamp, yellow led indicating lamp, amber led indicating lamp, red led indicating lamp, hotter, 230v ac, neutral link, control terminals, 1pole ac instantaneous high stability circulating current relay, micro processor based release, acc spreader terminal, aux contact, extended rotary handle, microprocessor based released, acc spreader terminal, microprocessor based released, acc spreader terminal, mccb with ti release, microprocessor based released, aux contactor with dc coil, timer, mccb with mp based release, extended rotary handle for above mccb, panel door mounted key lock for extended rotary handle, ct shorting terminals, closing release, uc release -, universal motor for breaker spring charge, shunt release, l.a.f.a.p ,for castell lock: u-power, micro switch for spring charging, kwh meter, kwh meter, led a meter, led a meter, led volt meter, maximum demand controller, phase loss + phase sequence (smr), aux. contactor with ac coil, aux. contactor with ac coil, emergency stop button, modular , no contact block, selector switch, white led indicating lamp, blue led indicating lamp, green led indicating lamp, yellow led indicating lamp, amber led indicating lamp, red led indicating lamp, white led indicating lamp, blue led indicating lamp, green led indicating lamp, yellow led indicating lamp, amber led indicating lamp, red led indicating lamp, hotter, 230v ac, neutral link, control terminals, 1pole ac instantaneous high stability circulating current relay, micro processor based release, acc spreader terminal, aux contact, extended rotary handle, microprocessor based released, acc spreader terminal, microprocessor based released, acc spreader terminal, mccb with ti release, microprocessor based released, aux contactor with dc coil, timer, mccb with mp based release, extended rotary handle for above mccb, panel door mounted key lock for extended rotary handle, ct shorting terminals
Tender For purchase of non-consumables for ece department - purchase, dual output regulated dc variable power supply input voltage: 230v/50 hz ac. output voltage: (0 30)v dc. output current: (0 2)a dc. protection circuit: over voltage, over current, and short-circuit protection. high efficiency: greater than 85%. low ripple and noise: less than 50 mv. digital display., function generator frequency range: 0.1 hz to 5 mhz. display: 4 to 6 digit led display. output waveforms: sine, triangle, square, pulse, ramp. amplitude: 0 20 vpp. rise time: 100 ns. distortion: 1% within specified frequency range. power supply: 230 v ac 10%, 50 60 hz. output amplifier protection: short-circuit and 15 v overload protection. dc offset: 0 to 10 v adjustable. attenuation: 0 to 60 db., dso (digital storage oscilloscope) bandwidth: 50 100 mhz. sampling rate: 1 gs/s. channels: 2 (minimum). power supply: 100 240 v ac, 50 60 hz. automatic measurements: vpp, vavg, vrms, frequency, period, vmax, vmin, rise time, fall time, +width, width, +duty, duty, etc. horizontal scale: 5 ns/div 50 s/div or equivalent. vertical resolution: 8 bits (2 channelssimultaneously). vertical sensitivity: 1 mv/div 10 v/div (at input). waveform math: +, , , , invert, fft, etc. waveform storage: 16 waveforms or equivalent. communication interface: usb host and usb interface. display: 7-inch color display or equivalent. input impedance: 1 m 2% || 20 pf. accessories: 2 passive probes (1x/10x)., digital ic trainer kit with breadboard +5 v dc, 1 a regulated power supply. 12 v dc / 15 v dc, 200 ma regulated power supply. solderless breadboard with minimum 840 tie points,power distribution buses. zif (zero insertion force) ic sockets to accommodate 8 or 16 pin ics. logic input and output leds for output monitoring. 16 buffered led outputs. 16 debounced switch inputs. variable clock generator: 0.5 hz to 50 hz. single pulse output: 100 ms (buffered, positive and negative outputs). one seven-segment display with 4 bcd inputs. built-in logic switches. manual clock: debounced push-button (one pulse per press)., lvdt trainer kit ac mains power supply: 230 v 10%, 50 hz. fixed regulated dc power supply: +5 v, 12 v / 500 ma. transducer: lvdt. lvdt displacement: 20 mm (40 mm total). displacement scale: linear 20 mm. displacement display: red color 3 digit led display. excitation frequency: 4 khz. excitation voltage: ac variable excitation voltage up to 5 v., strain guage trainer kit ac mains power supply: 230 v 10%, 50 hz metal foil strain gauge mounted on beam/cantilever. strain measurement under applied load. wheatstone bridge arrangement. signal conditioning and amplification circuit. instrumentation amplifiers with 3 digit display for strain / output voltage. zero and gain adjustment controls. provision for applying calibrated loads. table-top trainer with labelled panel. test points for signal measurement. built-in dc power supplies and wooden closed cabinet. supplied with patch cords and user manual.
Tender For supply, installation and testing of electronic equipments - supply -ece lab equipments, single output regulated dcvariable power supply- input voltage: 230v / 50hz ac. output voltage: (0 30)v dc. output current: (0 2)a dc. protection circuit: over voltage, over current, and short-circuit protection. high efficiency: greater than 85%. low ripple and noise: less than 50 mv. digital display., dual output regulated dc variable power supply- input voltage: 230v/50 hz ac. output voltage: (0 30)v dc. output current: (0 2)a dc. protection circuit: over voltage, over current, and short-circuit protection. high efficiency: greater than 85%. low ripple and noise: less than 50 mv. digital display., function generator - frequency range: 0.1 hz to 5 mhz. display: 4 to 6 digit led display. output waveforms: sine, triangle, square, pulse, ramp. amplitude: 0 20 vpp. rise time: 100 ns. distortion: 1% within specified frequency range. power supply: 230 v ac 10%, 50 60 hz. output amplifier protection: short-circuit and 15 v, digital ic trainer kit with breadboard - +5 v dc, 1 a regulated power supply. 12 v dc / 15 v dc, 200 ma regulated power supply. solderless breadboard with minimum 840 tie- points,power distribution buses. zif (zero insertion force) ic sockets to accommodate 8 or 16 pin ics. logic input and output leds for output monitoring. 16 buffered led outputs. 16 debounced switch inputs. variable clock generator: 0.5 hz to 50 hz. single pulse output: 100 ms (buffered, positive and negative outputs). one seven-segment display with 4 bcd inputs. built-in logic switches. manual clock: debounced push-button (one pulseper press)., dc voltmeter(digital) - dc digital voltmeter - 3 digit led/lcd display, measurement range: 0 20 v dc,accuracy: class 0.5( 0.5 % full-scale), dc ammeter - dc ammeter digital - 3 digit led/lcd display, measurement range: 0 5 a dc,accuracy: class 0.5 ( 0.5 % full-scale), lvdttrainer kit - ac mains power supply: 230 v 10%, 50 hz. fixed regulated dc power supply: +5 v, 12 v / 500 ma. transducer: lvdt. lvdt displacement: 20 mm (40 mm total). displacement scale: linear 20 mm. displacement display: red color 3 digit led display. excitation frequency: 4 khz. excitation voltage: ac variable excitation voltage up to 5 v., strain gauge trainer kit - ac mains power supply: 230 v 10%, 50 hz metal foil strain gauge mounted on beam/cantilever. strain measurement under applied load. wheatstone bridge arrangement. instrumentation amplifiers with 3 digit display for strain / output voltage. table-top trainer with labelled panel. test points for signal measurement. built-in dc power supplies and wooden closed cabinet. supplied with patch cords and user manual., ask modulation and demodulation kit - message signal1:8-bit variable data,amplitude 5v. message signal 2:debounced data, amplitude low (0) and high (5 v). message signal 3:fixed data 25 khz, 12.5 khz, 6.25 khz, 3.12 khz,amplitude 5 v. carrier signal: sine wave, frequency 200 khz, amplitude 5 v. supply voltage (board): +12 v, +5 v dc. input voltage: 230 v ac, 50 hz. interface connectors: 2 mm banana socket., fpga trainer kit - must use industry-standard mid-range fpga device usb-jtag programmable, compatible with vivado ise (webpack). power supply: 5 v dc through usb or external adapter. on-board peripherals: leds, switches, push buttons, 7-segment display,clock source, gpio / pmod expansion ports, uart, vga / hdmi, usb- uart bridge, usb cable. user manual., measurement scale: a vertical steel meter scale, usually with (1mm) graduations, for precise deflection measurement., accessories: includes a set of slotted weights (e.g., (6times 50g) or similar sets) for incremental loading.
Tender For supply of multi process control trainer setup for instrumentation engineering lab under mhrd scheme - purchase of multiprocess control trainer setup for instrumentation engineering lab under mhrd scheme - multiprocess control trainer set up, multiprocess control trainer set up - specifications:- setup must contain flow, pressure, level, temperature loops also derived loops like cascade and feedforward loops. temperature loop must be independent. setups consist of a circulating closed loop water plant or circulating water system including control valve, tanks, independent pumps and necessary valves including bypass valves and rotameters. using this we can be able to do flow control loop with pid,level control loop with pid,and pressure control pid, as independent experiments.the setup must include the following:1.one linear characteristics diaphragm operated control valve with 15mm stroke 1/2-inch size, type: high-capacity globe seat leakage class (as per ansi/fci 70.2).2.measuring tank with volumetric measurement scale and 1000mm level, in of 25 ltr capacity. sump tank min of 40 ltr capacity. all tanks made of ss304, with sight glass, and finished with mat steel finish.3.2 no s smart dp transmitter for flow and level measurement with hart protocol, display and keys integrated for calibration,0-1000mmh2o measurement range,0.01% accuracy, international iso certified ce approved make,24v supply,4-20ma output, loop powered.4,1nos of magnetic flowmeter with display and keys integrated for calibration,0-2000lph measurement range, read out: 0 - 100%, 4-20ma lcd display,0.05% accuracy, international iso certified ce approved make,24v supply,4-20ma output to measure flow as a independent loop.5,. smart pressure transmitter and temperature transmitters with hart protocol, display and keys integrated for calibration, pressure transmitter 0-10bar measurement range, read out: 0 - 100%, 4-20ma lcd display,0.05% accuracy, temperature transmitter 0-250 rtd type international iso certified ce approved make,24v supply,4-20ma output, loop powered.6, pressure tank of 24 liters with necessary valves for pressure loop.7.1nos orifice plate (ss304) and assembly grade with flange 1/2-inch size for flow measurement.8.2 nos pumps 0.5hp, ss centrifugal pump, minimum 1-inch pipeline of ss or high-pressure withstanding plastic with plastic welding.9. rotameters 2nos 1 inch size flow: 200-2000 l/h,ss thread, clear acrylic type.10, plc control station with 4 analogue inputs and one analogue output with necessary digital inputs and outputs to operate all loops directly from panel side.plc must have ethernet connectivity with supported protocols profinet and modbus tcpip.11.required all pneumatic components to full fill the process loops such as fr,needle valves etc.12,i to p converter 4-20ma to 3-15psi with 1/4" process connection with proper copper copper tubing.13, loop including flow pid control, level pid control, pressure pid control, cascade control (level flow), ratio control (flow flow).14.all loops can be operated using a scada system and independent pushbutton control includes trend of all analogue signals and pid tuning. scada direct profinet connectivity to plc and computer with intel i5 processor, 8gb ddr3 ram,1tb sata hdd,licenced windows 11 professional.15, required a standalone software application that must be installed on pc in which it can used to control and monitor all the functions used in scada. the application must contain process parameter trend graph plot for to study about process loops.16.the whole system setup must be in ms powder coated standalone mobile table with lockable castor wheels. all the components used be industrial. copper tubing for air connection, pressure gauges 4inches 3nos, electrical wiring connection to be flexible for to connect field devices. panel with switches, indicator, test points with banana connectors as required, multistrand wire with proper insulated lugs, ferruling & neat wire dressing & clam
Tender For operation & maintenance work for sewage treatment plant (20.20 mld) based on sbr with mcc panel room, diesel generator set and all contingent civil, electrical, mechanical, piping and instrumentation works of entire system for 5 years at valsad, district: valsad, gujarat (2nd call)
Tender For tender for supply of panel mounted mccbs - panel mounted mccb rated current- 63amps no. of poles- 03 ultimate short circuit breaking capacity(icu)at 415vac50/60 hz- 35ka or better service breaking capacity(ics)- 100% of icu adjustable overload and adjustable short circuit setting for line protection adjustable thermal and adjustable magnetic protection , panel mounted mccb rated current- 100amps no. of poles- 03 ultimate short circuit breaking capacity(icu)at 415vac50/60 hz- 35ka or better service breaking capacity(ics)- 100% of icu adjustable overload and adjustable short circuit setting for line protection adjustable thermal and adjustable magnetic protection , panel mounted mccb rated current- 125amps no. of poles- 03 ultimate short circuit breaking capacity(icu)at 415vac50/60 hz- 35ka or better service breaking capacity(ics)- 100% of icu adjustable overload and adjustable short circuit setting for line protection adjustable thermal and adjustable magnetic protection , panel mounted mccb rated current- 160amps no. of poles- 03 ultimate short circuit breaking capacity(icu)at 415vac50/60 hz- 35ka or better service breaking capacity(ics)- 100% of icu adjustable overload and adjustable short circuit setting for line protection adjustable thermal and adjustable magnetic protection , panel mounted mccb rated current- 250amps no. of poles- 03 ultimate short circuit breaking capacity(icu)at 415vac50/60 hz- 35ka or better service breaking capacity(ics)- 100% of icu adjustable overload and adjustable short circuit setting for line protection adjustable thermal and adjustable magnetic protection
Tender For lrt test bench for testing dc tm mounted on truck with wheels used in electric loco output 0 to 200 vdc, 200 amps input supply 400v 3-phase ac 50 hz 150 a, 50 hz complete with 3-phase 75 amps 415v oil cooled variac, control panel and 36 kva 400/190v sarola make step down transformer with protection and instrumentation( continuous) with following hand held meters: (i) hand held non-contact thermometer (ii) hand held tachometer. detail technical specification as per attached annexure-a [ warranty period: 30 months after the date of delivery ] ]