Tender For corrigendum : supply of steam water analysis system main spares and e and c c c - ph sensor , ph transmitter 4 to 20ma hart , specific conductivity sensor , specific conductivity transmitter 4 to 20ma hart , cat ion conductivity sensor with 1 cat ion exchange column , cat ion conductivity transmitter 4 to 20ma hart , do2 sensor , do2 transmitter 4 to 20ma hart , silica analyzer transmitter 4 to 20ma multi channel , sodium analyzer transmitter 4 to 20ma multi channel , conductivity analyzer -online retractable type , sample handling system for main steam superheated , sample handling system for main steam saturated , sample handling system for drum water , sample handling system for hp feed water economizer inlet , sample handling system for deae ol fw , sample handling system for condensate cep outlet inlet cooling wtr , sample handling system for dm water , redundant chiller units 1 working 1 standby , shelf life items required at the time of commissioning , shelf life items required after commissioning in 1st lot , shelf life items required after commissioning in 2nd lot , training as per cl 14 of 6 mandays at manufacture works and 6 mandays at site , mandatory spares as per tech specs , supervision of e and c services charges at site , supervision of e and c visit charges
Tender For corrigendum : supply of steam water analysis system main spares and e and c - ph sensor , ph transmitter 4 to 20ma hart , specific conductivity sensor , specific conductivity transmitter 4 to 20ma hart , cat ion conductivity sensor with 1 cat ion exchange column , cat ion conductivity transmitter 4 to 20ma hart , do2 sensor , do2 transmitter 4 to 20ma hart material code , silica analyzer transmitter 4 to 20ma multi channel , sodium analyzer transmitter 4 to 20ma multi channel , hc analyzer 4 to 20ma , sample handling system for main steam superheated , sample handling system for drum water , sample handling system for hp feed water economizer inlet , sample handling system for deae ol fw , sample handling system for dm water , sample handling system for condensate blow down line , sample coolers , redundant chiller units 1 working 1 standby , shelf life items required at the time of commissioning , shelf life items required after commissioning in 1st lot , shelf life items required after commissioning in 2nd lot , training as per cl 14 of 2 mandays for 6 nos at site , supervision of e and c services charges at site , supervision of e and c visit charges , mandatory spares as per tech specs
Tender For corrigendum : supply of spares of soot blowers of (2x600 mw), katpp, rvunl, jhalawar - "lance tube assembly with flange, nozzel and nozzel head pipe.soot blower location: plsh area (ik-1/2/3/4) in u#1& 2 respectively", "lance tube assembly with flange, nozzel and nozzel head pipe soot blower location: plsh area (ik-5/6/7/8/9/10) in u#1& 2 respectively", "lance tube assembly with flange, nozzel and nozzel head pipesoot blower location: fsh (ik-11/12/13/14/15/16), frh (ik-17/18/19/20/21/22),prh(ik-23/24), ltsh(ik-25/26) area in u#1& 2 respectively ", "lance tube assembly with flange, nozzel and nozzel head pipe soot blower location: prh(ik-27/28/29/30, ltsh area(ik-31/32/33/34/35/36)in u#1& 2 respectively", "poppet valve assembly for all lrsbsoot blower location: plsh/fsh/frh/prh/ltsh area", "poppet valve assembly for hrsbsoot blower location: economizer area", "screw tube (lance tube) with packing assembly for fsbsoot blower location: water wall area", "feed tube with flange for fsbsoot blower location: water wall area", "goose neck valve assembly for fsbsoot blower location: water wall area", "lance tube with multi -jet element nozzel assembly for aphsbsoot blower location: air pre-heater area"
Tender For supply of spares for existing steam boilers available in ttd temples and institutions tirupati for the year 2026 27- 1/2 x 0.50 m metallic hose , 15mm nb size , 20mm nb size , 3/8 x 0.75 m metallic hose , asp-0 kolb - water filter p01rds0820 (thermax) , bearing piece , blow down limit switch (thermax) , burner rod assembly-0314824110 (thermax) , by pass valve 1/2" dia , cable high tension, pvc-0034121100 (thermax) , coil - psgcl10001 (thermax) , diesel transfer pump 0.5 hp 3 phase, flame proof , electrode assembly-0314613200 (thermax) , electrode cap-8611111100 (thermax) , engaging of welder 1st class for welding works in all canteens , filter 1/4" bsp (f)-8907111101 (thermax) , filter element - p01rds0770 (thermax) , for 100 kg/hr boilers , for 200 kg/hr boilers , fuel pump - as 47 a - p21esp0190 (thermax) , fuel pump an 67-8220125000 (thermax) , gland washer - p01rds0090 (thermax) , hardness test kit , hire charges for welding set whenever necessary by the department for attending the welding works in all canteens , hooter 4" dial, 220v-8610111500 (thermax) , nozzle 2.25 gph, 45 deg plp-8904112600 (thermax) , packing retainer , packing washer , photo resistor 8205, petercem-8603111400 (thermax) , piston htn-1-8110126900 (thermax) , pr. switch- 0.1 to 1.1 bar - p41ps1q/10 (thermax) , pr. switch- 1 to 16 bar - p41ps10040 (thermax) , pr.gauge,brdn- wpg, ss- & 25/nr @ p100-1w fpt- bt, mnfc - p61pg20010 (thermax) , pressure guage 0 to 25 kg-8451141800 (thermax) , pressure guage 0 to 40 kg-8451141900 (thermax)) , pressure switch pm - 1po-w-8441133200 (thermax) , pressure switch pvf 16 (thermax) , pump- d' kolb- simplex, 200 lph - p01rd10010 (thermax) , pump, simplex-8110125000 (thermax) , resin , rxa-02 coil- prxcl 10004 (thermax) , rxa-02 economizer- prxec10016 (thermax) , rxa-02 optomizer-prxec10017 (thermax) , s & f gunmetal (gm) ball valve with ss ball and ss spindle as per ls - class - l, indian make heavy type - 20 mm nb size , s & f gunmetal gate (gm peet) valve as per is - 778 class - i, indian make heavy type , sequence controller ma 810-8605111600 (thermax) ) , sight glass (thermax) , softener 40 nb multi port valve & fittings (thermax) , supply of ball valve 25nb ci f/e (thermax) ) , supply of electronic timer- p42g210050 (thermax) , supply of photo cell for sg-005 (thermax) , supply of steam stop valve bronze bspt 25nb- p33lg20050 (thermax) , supply of the following materials required for the maintenance of steam boilers available in ttd temples & institutions at tirupati. (the following rates are excluding gst) , supply of the following spare parts required for thermax boilers available at various places, hostels in tirupati and tiruchanoor. (the following rates are excluding gst) , temp. element pt-100, with cable 2.5 m - (thermax) , temperature controller 0-400, dtc/2 v.trafag-8421117200 (thermax) , thermometer 0-120 deg, 63 mm dial-8481126000 (thermax) , transformer 14.5 kv-8609111100 (thermax) , valve seat assembly , valve seat assembly.(htb-3tohtb-6) - p01rds0320 (thermax) , valve, ball 3/4" bspt-9770101900 (thermax) , valve, needle- ss 304 (thermax) , valve, non r-om-thd- 1/2" bspt, mnfc - p33ng2001m (thermax) , valve, safety 25mm, 150-250 psi-9722122400 (thermax) , washer gland
Tender For providing comprehensive consultancy services for preparation of design concept plan, architectural drawings, all types of local body approvals, structural design, civil, electrical and mechanicalengineeringservices design drawing, landscape design & drawings including preparation of detailed estimate (civil, electrical& horticulture), digital survey and soil investigation for the construction of rbi staff complex for staff (class iii) at bhandup, mumbai (date of nit available: may 14, 2026)
Tender For corrigendum : construction of office building for reservice bank of india (la-gajjar chambers) at ashram road, ahmedabad. sh: providing comprehensive consultancy services for preparation of architectural drawings, structural design, civil, electrical and mechanicalengineeringservices design and drawings. landscape design and drawings including local body submission and obtaining all statutory approvals from local authorities or any other authorities from commencement of work to building use permissions, prepartion of detailed project report, tender documents etc.
Tender For providing comprehensive consultancy services for preparation of architectural drawings, structural design, civil, electrical and mechanicalengineeringservices design and drawings, landscape design and drawings including local body submission and obtaining all statutory approvals from local authorities or any other authorities from commencement of work to building use permissions, preparation of detailed project report, tender documents, etc., ahmedabad
Tender For corrigendum : providing comprehensive consultancy services of architectural drawings, structural design, civil, electrical and mechanicalengineeringservices design/drawing, landscape design including preparation of detailed estimate (civil, electrical&horticulture) for the proposed admin block ,mi block and auditorium building in the nsg campus at the regional nsg hub ,jogeshwari vikhroli link road,milind nagar ,andheri(e),mumbai.