Get complete information related to latest Mechanical Wire Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Mechanical Wire Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Mechanical Wire Tenders.
Tender For corrigendum : supply of control cable for power transformer protection of various 33/11 kv substations under electrical testing division-mau.
Tender For annual contract rate for supply of building electrical fitting material - supply of building electricals fitting materials, pvc insulated cable fr with copper multi strand conductor isi marked 2x2.5 mm, pvc insulated cable fr with copper multi strand conductor isi marked 2x4 mm, pvc insulated cable fr with copper multi strand conductor isi marked 2x1.5 mm, pvc insulated cable fr with copper multi strand conductor isi marked 1.0 mm, approved make electronic dimmer/requlator for fan 650w, approved make electronic dimmer/requlator for fan 1000w, ceiling fan (energy saver 50 w)-1200 mm sweep, ceiling fan (energy saver 50 w)-1400 mm sweep, approved make wall mounting fan complete with wall bracket ,canopy,blades,speed regulator 400 sweep, approved make fresh air fanac 230-250 volts 300 sweep, approved make exhaust fan heavy duty with mounting frame,blades ac230-250 300mm sweep 900 rpm, approved make exhaust fan heavy duty with mounting frame,blades ac230-250 380mm sweep 900 rpm, servicing & overhauling of cooler fan motor, pump including replacemnt of distribution & delivary pipes,pvc elbows, painting etc. as reqd. complete with nacessary material & labour including replacement of connection leads., cleaning,overhauling, servicingof ceiling /exhaust /wall bracket fanby applying grease & oil, including testing with mounting / hanging arrangement including replacement of saftypins, checknuts,locknut,nut bolts etc. making perfect allignment & refitting at site as required., rewinding of fans by copper enamelled wire of suitable gauge including all required material, insulation, varnishing,connection leads,oiling .greasing etc completewith testing including dismentalling& refitting of fan at site.scrap old material is not returnable to the department., providing & refilling of wood wool /khas pads of normal size cooler panels 3 nos includings craping of oldpaint,making surface even,painting withred oxideprimer & two coats of paint of required shade including fixingnew wiremesh complete, chemical servicing of window /split air conditioning unit 1.5tr /2tr capacity including cleaning of cooling &condensing units,filters,grills etc & all other parts oiling & greasing of fan motor testing of a.c unit etc, cleaning,overhauling, servicingof ceiling /exhaust /wall bracket fan by applying grease & oil, including testing with mounting / hanging arrangement including replacement of saftypins, checknuts,locknut,nut bolts etc. making perfect allignment & refitting at site as required., labour rateforpointwiringalight /fan/twincontrol light /socketout let on seperateboard / call bell point in (open) surface rigid steel conduit system., labour rateforpointwiringalight /fan/twincontrol light /socketout let onseperateboard/callbellpoint inrecessed/concealed rigidsteelconduit system., labour rateforpointwiringalight /fan/twincontrol light /socketout let on seperateboard / call bell point in (open) surface rigidpvcconduit system., labour rateforpointwiringalight /fan/twincontrol light /socketout let onseperateboard/callbellpoint inrecessed/concealed rigidpvcconduit system., labour rateforpointwiringapowerpoint inrecessed/concealed rigidsteel conduit system including labour for fixing earth continuity conductor ., labour rate for fixing rigid pvc conduit as per specification in recessed/concealed conduit wiring system.20mm, labour rate for drawingcables inexisting rigidsteel conduit ( surfaceor recessed/concealed ) "a" 2 wires -1 2.5 sq mm / 4 sq mm / 6 sq mm, xlpe insulated power cable (conformingis-7098 ) 1100 volt grade/heavy duty powerc unarmoured 2 core 6 sqmm, led of 1 to 3w each assembled on single mcpcb, having color temp 6500k & having 50000 burning hrs life with minimum @l70,led luminiare 1 x 1, 24w , 4-6.5k, led of 1 to 3w each assembled on single mcpcb, having color temp 6500k & having 50000 burning hrs life with minimum @l70,led luminiare 2 x 2, 36w, 4-6.5k, led luminiare 1x1, 24w p
Tender For i) development of site and bulk services (electrical & civil) for hospital buildings towards navarkulam corner of jipmer campus, puducherry. sh: re-routing of existing 6 runs of 22 kv ht cable on back side of the rcc phase-iii building. 2) construction of 400 bedded boys hostel building at jipmer campus, puducherry. sh: supply and testing of 22 kv underground cable to power grid corporation of india limited.subwork/packages:electrical
Tender For providing and installation of electrical accessories and allieds works at shaspur pwss, block-rampurhat-ii under bolpur mechanical division - supply, delivery at site and storage of wall mounted made of sheet steel fabricated 2 mm for load bearing & 1.6mm for non load bearing, indoor type, dust & vermin proof, lp-54 degree of protection, powder coated painted with rubber gaskets cover, front lockable hinged door with all switchgear and other items duly wired up and tested as per specification: incomer: (a) 100 amps, tpn mccb with adjustable ol, 36 ka, e/f, auto phase corrector & necessary accessories with suitable spd (i.e., ammeter, voltmeter, cts & switches), outgoing:- (b) 7.5 hp to 12.5 hp, tp star-delta starter with other accessories - 1 nos., (suitable size capacitor bank to improve pf from o.85 to 0.98) (c) yard lighting feeder with necessary accessories & time switch(digital) - 1 no. (d) 3phase actuator valve starter with other accessories -1 nos., (e) 2 hp ,3 ph,415v,clorinator feeder with necessary accessories & level controller-1 no., (f) 32a mccb fdr for iep/misc purpose-1no., (g) 32a mccb for in house light-1no.,(e) plc feeder with necessary accessories-1no.( all spare & components as per vendor list of phed), supply and delivery at site of 15 kva, 3phase, oil cooled type servo motor operated copper wound line voltage corrector conforming to is-9815 (pt.-1)- 1994 suitable for un-balanced input voltage with following specification including first filling oil as per is-335 where applicable.a) input voltage:- 3 phase, main supply may or may not be balanced with respect to phase to phase- 200v-500v phase to neutral-115v-290v.b) output voltage:-3 phase balanced output voltage. phase to phase- 400vor 415v 1%, phase to neutral- 230v-240v 1% (provision should be made to adjust the variation of output voltage per phase by a variable pot oil within 5% of output).c) line regulation:- out put voltage should remain well with 1% of set voltage (from minimum to maximum i.e. either 400v. or 415v. supply variation).d) load regulation : output voltage should remain neutral well within 1% of set voltage be ( from no load to full load ) i.e. either 400v. or 415v.e) correction speed:- better than 35 volt / second.f) efficiency:- better than 95% on full load.g) cut off limit (minimum &maximum ) by limit switch with audio & visual.h) metering indication:- by selector switch provision should be made available to measure input mains supply and output voltage other stabilizer for load current measurement an ammeter with selector switch should be available.i) lamp indication :- for input & output should be provided. ( 3 lamps per side ).j) mcb protection: for input side.k) load protection : hrc fuse on each output phase should be availablel) output over shoot:- beyond 210v to . 255v /phase in case of manual mode & voltage protection :auto mode operation.m) visual indication for under voltage & over voltage of output.n) manual mode:- up & down correction with o / p voltage over shoot protection. beyond 210 v-255 v. per phase.o) nature of cooling:- oil cooled system.p) electric current over load protection .q) circuit for delay output .r) input high voltage cut-off above 500 v.s) mode of operation:- auto/manual with a provision to restore the normal working of the unit standby operation should be available in case of any electronic failure in auto mode., installation of mcc panel along with main switch, changeover, busbar chamber, cut out etc. all electrical equipment within the pump house, drawing of cable properly on suitable size gi cable tray on wall / as per direction of eic as per layout & ie rules and all connection with supply necessary materials, cable etc to complete the work, making arrangement with supply & fixing of materials for taking power within the pump house from wbsedcl end as per direction of eic. [for ph no - i, ii & iii], installation of above supplied stab