Get complete information related to latest Mechanical Wire Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Mechanical Wire Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Mechanical Wire Tenders.
Tender For supply of endless v-belt (precision built belt) having polyester cord reinforcement and neo-prene jacket with oil resistance and anti-static low stretch properties in size c-122 confirming to rdso specn.no. rdso/pe/spec/ac/0059-2004 (rev-0) with amendment no.1, which incorporates temperature aging and accelerated aging test and others additional physical parameter, with only 2 successive gradingnos. in a matched set of 12 belts and the grading no. in the range of 49 to 51. [ warranty period: 30months after the date of delivery ] ]
Tender For re tender engineering items (only oem & authorized dealers) - c.s welding electrode essen 9018 lh size-3.15 mm make- essen/ador/d&h secheron/arf/ewac, role guard grease ptfe rainforced grease 1kg. packing , epdm (shore -70 - 90) shorerubber sheet for juice heater right angle valve for vapour line suitable for 150°c with test certificate drg. no.- bssuk-02-04, make - petco/techno industrial/merutrubber/uttarkhand rubber, epdm (shore -70 - 90) rubber sheet for 1st body exhaust line valve suitable for 150°c with test certificate drg. no.- bssuk-04-04, make - petco/techno industrial/merutrubber/uttarkhand rubber , epdm (shore -70 - 90) rubber sheet for 1st effect right angle valve for vapour line suitable for 150°c with test certificate drg. no.- bssuk-26-04, make - petco/techno industrial/merutrubber/uttarkhand rubber, epdm (shore -70 - 90) rubber sheet for right angle valve 650m² suitable for 150°c with test certificate drg. no./ bssuk/b.h./88, make - petco/techno industrial/merutrubber/uttarkhand rubber, epdm (shore -70 - 90) rubber sheet for vapour valve evaporator 1st body suitable for 150°c with test certificate drg. no./ bssuk-150/11, make -petco/techno industrial/merutrubber/uttarkhand rubber, epdm (shore -70 - 90) rubber sheet for 2nd body right angle valve suitable for 150°c with test certificate drg. no./ bssuk- 138/08, make - petco/techno industrial/merutrubber/uttarkhand rubber, epdm (shore -70 - 90) rubber sheet for juice heater suitable for 150°c with test certificate drg. no.- bssukm 139/04, make - petco/techno industrial/merutrubber/uttarkhand rubber, epdm (shore -70 - 90) rubber sheet for 1st body suitable for 150°c with test certificate drg. no.- bssuk-123/07, make - petco/techno industrial/merutrubber/uttarkhand rubber, epdm (shore -70 - 90) rubber sheet for right angle valve 800m² suitable for 150°c with test certificate drg. no./ bssuk/b.h./109, make - petco/techno industrial/merutrubber/uttarkhand rubber, epdm (shore -70 - 90) rubber sheet for right angle valve suitable for 150°c with test certificate drg. no./ bssuk/b.h./108, make - petco/techno industrial/merutrubber/uttarkhand rubber, epdm (shore -70 - 90) rubber sheet for dynamic juice heater right angle valve suitable for 150°c with test certificate drg. no./ bssuk/b.h./24/10, make -petco/techno industrial/merutrubber/uttarkhand rubber, epdm (shore -70 - 90) rubber sheet for double beat valve 8" suitable for 150 ºc temp. as per with test certificate drg. no. bssuk/b.h./89, make - petco/techno industrial/merutrubber/uttarkhand rubber, epdm (shore -70 - 90) rubber sheet for juice heater right angle valve suitable for 150 ºc with test certificate drg. no./bssuk/b.h./89/200, make -petco/techno industrial/merutrubber/uttarkhand rubber, epdm rubber cord suitable for 150°c size 11x13x15mm, make -petco/techno industrial/merutrubber/uttarkhand rubber, epdm rubber cord suitable for 150°c size 13x15x17mm, make -petco/techno industrial/merutrubber/uttarkhand rubber, epdm rubber cord suitable for 150°c size 18x15x15mm, with test certificate , star coupling set r-70, make - riddhi, rubber star coupling set l-95, make - rathi/love joy, rubber star coupling set l- 100, make - rathi/love joy, rubber star coupling set l- 110, mak - rathi/love joy, rubber star l- 95, mak - rathi/love joy, rubber star l- 100, mak - rathi/love joy, rubber star l- 110, mak - rathi/love joy, "rubber star coupling size - 190mm make - rathi/love joy", pump body s.s. 304 , pump type - 100-65-250 et capacity - 20m³/hr, head - 30 mtr., rpm - 1475, make -mather & platt, pump shaft for pump type- smf 400 x450 ,sr.no.-593 year-2003 cap.-2500 m3/hr. head-15 mtr.,rpm-960 motor h.p-200 make- sintech moc- s.s 410 , "mill house cane carrier chain assembling breaking load of the chain will be 80,000 kgs. as per is : 8465-1990 (r1995) pitch 150mm with test certificate moc as per drg. no. - c-mh-3122 (heat treated)make - 1. aypee industries, jalandar 2. swajeet, jalandhar 3-raj amar 4. n.v. kalia
Tender For supply of flexible cords pvc insulated circular sheathed, stranded copper conductor, 1.5 sq.mm, 3 core conforming to is: 694:2010 with amendment no. 1/2012 and the class 6 of is: 8130/1984 (reaffirmed 2001) for flexibility. the cord shall be with isi marking. technical parameters: 1.type of cable: pvc type d insulated, circular sheath type (hr). 2. construction: flexible cords, class 6. 3. type of conductor: copper conductor, stranded confirming to is: 8310:1984 (reaffirmed 2001). 4. nominal area of conductor in square mm: 1.5 sq.mm. 5. no. of core: 3 6. isi marked: yes. 7. availability of type test report from central govt/ nabl approved / ilac accredited lab to prove conformity to the specification and test reports shall furnish to consignee. 8. governing specification: is: 694:2010 with amendment no.1/2012. [ warranty period: 30 months after the date of delivery ] ]
Tender For miscellaneous items for hpb and liver transplant surgery ot - radiopaque gauze :-should be sterile gauze & made up of 100% cotton gauze fabric type ep 17- x ray detachable should be weaved x ray 100% barium sulphate or metal it should be lint free, non irritating, latex free, and tissue size:- 10*10 cm*12 ply lint free non pack size 1*4 pc., vircyl sutupac 1, 1-0, 2-0 ,3-0 ,4-0, cautery pincil size 9 , electro surgical cautery tip cleaner, micro suction tip canula, liver biopsy gun, c. arm camera cover, usg prob cabel and camera cover, trolley covers, mayo trolley covers, pounch- opsite drap pouch drape:- 2 incise film provides continuous broad-spectrum antimicrobial activity to help reduce the risk of surgical site contamination incise drape adheres to the operative site, creating a sterile surface at the beginning of surgery 360-degree pouch provides optimal fluid collection to minimize contact with fluid and helps reduce the risk of contamination to or team pouch allows for easy clean-up and saves time comes with tube and cord organizers. a clear, plastic, 360-degree fluid collection pouch with tube and cord organizers. size 30*30 cm, steridrip (basic surgical pack), inj. methylene blue 1.0% 10ml ampoule, inj. albumin 5% (100ml), inj. calcium chloride (100 mg/ml), inj. diltiazem (5 mg/1ml, inj. phenylephrine (10mg/1ml) in ampoule size, inj. dns 500ml (double layered sterile plastic polybag), inj. dns 500 ml ( in sterile double layered sterile plastic polybag), inj. ns 500 ml (in sterile double layered sterile plastic polybag), inj. ns 500 ml (in sterile double layered sterile plastic polybag), inj. ns 1000 ml (in sterile double layered sterile plastic polybag), inj. ns 1000 ml (in sterile double layered sterile plastic polybag), 0.33 ns (double layered sterile plastic polybag), 0.33 dns (double layered sterile plastic polybag), 3% ns (double layered sterile plastic polybag), inj gelofusion 500ml, single arterial & cvp pressure transducer ( compatible with edwards continuous cardiac output monitor ) one disposable pressure transducer having gold plated connector tip for best signal quality with flush device & vent stopcock, iv set, 2 three way stopcocks it should have special hood to reduce contamination risk. gold-plated connector wires for high-fidelity signal transmission. available with a snap-tab flush device that can be easily gripped and stretched 360 to quickly and easily flush the system and generate a square-wave test pattern. it should have a flow rate of 3 +/- 1 ml/hr under 300 mm hg iv bag pressure. should be usfda approved., arterial catheter 3fr-l-8cm usfda approved, gamjee roll, ky jelly, l-70 for fluid warmer set, d1-100 tubings for rapid fluid transfusion, hd catheter (size : 11.5 | 8.5 | 9 | 9.5 |10 | 10.5 ), et tube with suction port (size : 7 | 7.5 | 8 | 8.5), single pressure transducer with closed blood sampling system adult(vamp kit) one disposable pressure transducer having gold plated connector tip for best signal quality with flush device & vent stopcock, iv set, 1 shutoff valve, 60 patient pressure tubing along with inbuilt inline 12 cc reservoir & 2 self-sealing z-site sampling ports located 13 and 55 from patient for closed blood sampling; pole mountable. it should have special hood to reduce contamination risk. gold-plated connector wires for high-fidelity signal transmission. available with a snap-tab flush device that can be easily gripped and stretched 360 to quickly and easily flush the system and generate a square-wave test pattern, patient dress anti-bacterial ,anti-virus and anti-fungi :- fabric should be effective against bacteria , viruses, fungi, absorbency factor of less than 1 sec as per aatcc-79.has moisture wicking factor of 5 sec as per aatcc 197, fabric made up of 94% polyester ,6% spandex and 180 gsm +/-5% , free from toxin substances , breathable , skin friendly, antiseptic property ,should be iso 13485, cdsco & ce approved. size :- small to xl, pressure
Tender For item type: supply of digital multifunction insulation tester having function of fault loop & lineimpedance measurement range 10 ohm/20 ohm/200 ohm/2000 ohm & resolution .001 ohm/0.01 ohm/0.1 ohm/1 ohm, with rcd testing non trip feature prospective earth fault current, psc test (short circuit measurement) range 1000a/10ka (50ka) resolution 1a/0.1ka. ac voltage measurement range 500v & resolution .iv insulation resistance measurement (riso) test voltage 50 - 100 - 250 - 500 - 1000 v, accuracy of test voltage (at rated test current + 10% - 0%), test voltage range 50v - 1000 v, insulation resistance range - 20m ohm/50m ohm/100m ohm/200m ohm/1000m ohm & resolution .01m ohm/0.m ohm/1m ohm, input impedance- 360 k ohm, over load protection- 660 v ohm ms, test current i ma ( 50 k ohm, 100 k ohm, 250 k ohm, 500 k ohm, 1 m ohm, continuity testing (rlo) range (auto ranging) 20 ohm/200 ohm/2000 ohm, open circuitvoltage >4v, earth resistance measurement 2 pole & 3 pole with accessories, rcd testing for type ac, ab, & programmable rcd bluetooth connectivity, internal memory for test data storage, rechargeable battery 6xaal (iel lr6) c 1600 hard carrying case, zero adapter, heavy duty mains cord, standard test lead set, padded carrying & waist strap, tp 165x remote control probes [ warranty period: 30 months after the dateof delivery ] ]
Tender For corrigendum : supply of various items for treatment of patients in different departments under m-aay, cm-nnry and rghs. rate contract for 2 years - sterile hypodermic syringe with needle attached, 24 g, single use-2ml clear transparent chamberprominent graduationinert material gasket at the piston to minimize friction during movement & prevent leakage and back flowsharp needle ensuring minimum trauma during penetrationshall conform to relevant is for syringe-is 10258 and for needle is 10654packing:needle should be attached with the syringe and packed in unit ribbon pack the word "destroy after single use" or equivalent should be written on unit container., sterile hypodermic syringe with needle attached,24 g, single use-5mlclear transparent chamber prominent graduationinsert material gasket at the piston to minimize friction during movement & prevent leakage and back flow sharp needle ensuring minimum trauma during penetration shall conform to relevant is for syringe-is 10258 and for needle is 10654packing:needle should be attached with the syringe and packed in unit ribbon pack the word "destroy after single use" or equivalent should be written on unit container., sterile hypodermic syringe with needle attached,22 g, single use-5mlclear transparent chamber prominent graduationinsert material gasket at the piston to minimize friction during movement & prevent leakage and back flow sharp needle ensuring minimum trauma during penetration shall conform to relevant is for syringe-is 10258 and for needle is 10654packing:needle should be attached with the syringe and packed in unit ribbon pack the word "destroy after single use" or equivalent should be written on unit container., sterile disposable perfusion set (infusion set) with airway and needle (paediatric use) burette type measured volume chamber of 100mldrope size ofapprox 60drope per mlinjection port ,latexfree,for intermittent medicationfloating auto shut off valve in burette latexfreesoft and kink resistantpvc tubing.roller controller for flow controltube length 150cm23 g needleas per isd 8536-5, surgical spirit ip(500ml), surgical spirit ip(100ml), umbilical cord clamp, paper adhesive plaster 3inch * 9.0 mts (with cutter )non woven, non allergic and strong adhesive but gentle to skin should conform to the standards and test as per is and bp standard, absorbable surgical (synthetic) antibacterial with sterilised needled suture (braided coated polyglaction/ polygiycolic acid violet)size 2/0 ½ circle round bodied 30 mm suture length 90mm, absorbable surgical (synthetic) antibacterial with sterilised needled suture (braided coated polyglaction / polygiycolic acid violet)size 3/0 ½ circle round bodied 20mm suture length 70mm, polypropylene nonabsorable synthetic surgical mesh 7.6 cm*15 cm or 7.5cm*15 cm, polypropylene nonabsorable synthetic surgical mesh 15 cm*15 cm, paper adhesive plaster 2inch * 9.0 mts (with cutter )non woven, non allergic and strong adhesive but gentle to skin should conform to the standards and test as per is and bp standard, ryles tube/ nasogastric tube size:14, k wire length 375mm 1.6mm, ryles tube/ nasogastric tube size:10, ryles tube/ nasogastric tube size:12, non absorbable surgical suture sterilised needled monofilament polypropylene blue size 2/0 (1/2 cir rb needle 30mm, lenth 90mm), rubber examination gloves size medium, endotracheal tube cuff size :-8, endotracheal tube cuff size 8.5, pop bandage 6", pop bandage 4", gloves size 6 inch ,powder free (disposable sterile surgical rubber gloves), gloves size 6.5 inch ,powder free (disposable sterile surgical rubber gloves), gloves size 7 inch ,powder free (disposable sterile surgical rubber gloves), gloves size 7.5 inch ,powder free (disposable sterile surgical rubber gloves), gloves size 6 inch ,powdered (disposable sterile surgical rubber gloves), gloves size 6 .5inch ,powdered (disposable sterile surgical rubber gloves), gloves size 7 inch ,powdered (disposable sterile surgical rubber g